Cleveland KET-3-T Operator's Manual

Cleveland KET-3-T Operator's Manual

Electric table top kettles
Hide thumbs Also See for KET-3-T:

Advertisement

Operators Manual
For units built after August 1999
MODELS:
Single Kettles
KET-3-T
KET-6-T
KET-12-T
KET-20-T*
Twin Kettles
TKET-3-T
TKET-6-T
TKET-12-T
*
Floor Type Leg Mount
Enodis
Installation, Operation & Service
Electric Table Top Kettles
1333 East 179th St., Cleveland, Ohio, U.S.A. 44110
Phone: (216) 481-4900 Fax: (216) 481-3782
Visit our web site at www.clevelandrange.com
SE95004 Rev. 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KET-3-T and is the answer not in the manual?

Questions and answers

Summary of Contents for Cleveland KET-3-T

  • Page 1 Operators Manual Installation, Operation & Service Electric Table Top Kettles For units built after August 1999 MODELS: Single Kettles KET-3-T KET-6-T KET-12-T KET-20-T* Twin Kettles TKET-3-T TKET-6-T TKET-12-T Floor Type Leg Mount Enodis 1333 East 179th St., Cleveland, Ohio, U.S.A. 44110 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www.clevelandrange.com...
  • Page 2 TABLE OF CONTENTS Installation Operating Instructions Cleaning Instructions Service Parts Maintenance Symbol Legend...
  • Page 3: Shipping Damage Instructions

    Specification Sheets or Specification Drawings for detailed clearance requirements of the kettle. Next, carefully cut open the shipping carton for easy removal of the kettle. CLEARANCE REQUIREMENTS Model # Back* KET-3-T 2 1/4” KET-6-T 2 3/4” KET-12-T 5 1/2” KET-20-T 8”...
  • Page 4: Wire Connection

    ASSEMBLY Table-Top Models (3, 6 & 12 gallon) 14.5" 1.25" 1.25" 1.25" KET-3-T KET-6-T 12.5" 10" KET-12-T 1.25" 18" 1.25 " TKET-3-T TKET-6-T 10" TKET-12-T 1 1/4" Model # TKET-3-T 18" TKET-6-T 24" TKET-12-T 30" Base Mounting Diagram Table-top models (3, 6 & 12 gallon - single and twin) must be positioned on a firm, level stand, or existing counter top, and bolted in place.
  • Page 5: Installation Checks

    WATER The sealed jacket of the electric kettle is precharged with the correct amount of a water based formula, and therefore, no water connection is required to the kettle jacket. The kettle can be equipped with optional hot and/or cold water faucet, requiring 1/2"...
  • Page 6: Operating Instructions

    OPERATING INSTRUCTIONS General Parts Drawing ITEM # DESCRIPTION Tilting Handle Vacuum/Pressure Gauge Pressure Relief Valve (not shown) Low Water Indicator Light (Red) On-Off Switch/ Solid State Temperature Control Heat Indicator Light (Green) Marine Lock FUNCTION Used for tilting the kettle. Indicate steam pressure in PSI inside steam jacket as well as vacuum in inches of mercury.
  • Page 7: Approximate Boiling Times

    OPERATING THE KETTLE DO NOT LEAN ON OR PLACE OBJECTS ON KETTLE LIP. SERIOUS INJURY COULD RESULT IF KETTLE TIPPED OVER, SPILLING HOT CONTENTS. 1. Before turning kettle on, read the Vacuum/Pressure Gauge (2). The gauges needle should be in the green zone. If the needle is in the "...
  • Page 8: Cleaning Instructions

    MARINE LOCK Your unit is equipped with a marine lock to prevent LATCH accidental tilting. The following procedure should be used to tilt the kettle. 1. Grasp the tilt handle. CLEANING INSTRUCTIONS CARE AND CLEANING Your kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operation.
  • Page 9: Recommended Cleaners For Specific Situations

    RECOMMENDED CLEANERS FOR SPECIFIC SITUATIONS Cleaning Agent Routine Cleaning Soap, Ammonia Detergent, Medallion Fingerprints Arcal 20, Lac-O-Nu & Smears Ecoshine Stubborn Stains Cameo, Talc, Zud & Discolouration First Impression Grease & Fatty Acids, Easy-Off, De-Grease It Blood, Burnt-On Foods Oven Aid Grease &...
  • Page 10: Service Parts

    SERVICE PARTS WARRANTY Our Company supports a worldwide network of Maintenance and Repair Centers. Contact your nearest Maintenance and Repair Centre for replacement parts, service, or information regarding the proper maintenance and repair of your cooking equipment In order to preserve the various agency safety certification (UL, NSF, ASME/Ntl. Bd., etc.), only factory- supplied replacement parts should be used.
  • Page 11 KETTLE BOTTOM & SIDE ITEM NO. PART NO. KE50556-1 KE51723 KE52455 KE52456 KE52457 KE52459 KE00515 KE50558 FA11145 FA21007 KE50429-3 KE54852-1 FA11145 DESCRIPTION Probe, Low Water ........1 Safety Valve, 50 PSI, 1/2"...
  • Page 12 CORD & PLUG OPTION ITEM NO. PART NO. FOR KET-6-T (SW) KE02113-1 KE54819-1 KE54820-1 KE54821-2 KE54721-3 FOR KET-6-T (HW), KET-12-T (SW), KE02113-2 KE54819-2 KE54820-2 KE54821-3 KE54721-4 FOR KET-12-T (HW) KE02113-3 KE54819-2 KE54820-2 KE54821-4 KE54721-5 DESCRIPTION Cord Plug Assembly ........1 Plug (30A) .
  • Page 13 CONSOLE COMPONENTS & MARINE LOCK...
  • Page 14 Hex Nut, 1/4-20 ..........1 / 2 Labels (KET-3-T, KET-6-T, KET-12-T, KET-20-T) ......1 (TKET-3-T) .
  • Page 15 TILTING GEARBOX ASSEMBLY (12 gallon kettle only) ITEM NO. PART NO. DESCRIPTION 1.-16. KE02062-1 Tilting Gearbox Assembly ........1 KE02060 Gearbox Housing .
  • Page 16 ELECTRICAL PANEL ITEM NO. PART NO. KE54761 SK50055-1 SK50054-2 SK50054-1 KE50753-7 KE50749-2 KE51139-1 KE52936-1 KE53838-21 KE00458 KE51225 KE51226 KE50343-1 ELECTRICAL PANEL DESCRIPTION Terminal Block Mounting Strip ......1 / 2 Terminal Block .
  • Page 17: Inspection And Maintenance Check List

    MAINTENANCE ALL SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN. Cleveland Range equipment requires little preventative maintenance. We do however provide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECK LIST The following check should be completed every six months or more frequently if unit is in a high volume facility.
  • Page 18 BEARING LUBRICATING PROCEDURE 1. Remove console cover. 2. Loosen two Allen screws on locking ring. 3. Pull locking ring to center of trunnion. 4. Pull kettle two inches away from console and rest on support block. 5. Clean newly exposed sections of trunnion. 6.
  • Page 19: Pressure Relief Valve Periodic Testing Procedure

    CALIBRATING PROCEDURE Insure the unit has a vacuum before you begin calibrating procedures. If unit requires venting refer to Kettle Venting Instructions on page 18 of this manual. Turn kettle ON and set temperature dial to 10 (Max.). Allow the unit to cycle twice. Check temperature of the inner kettle surface with a digital surface thermometer.
  • Page 20: Kettle Venting Instructions

    RESERVOIR FILL PROCEDURES The kettle's water level must be maintained at the proper level to submerge the heater elements. Under normal operating conditions, the sealed water reservoir should never require the addition of water. If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically low level.
  • Page 21: Vacuum Leak Test Procedure

    VACUUM LEAK TEST PROCEDURE If the kettle will not hold vacuum, test for leaks at: A. Water Level Probe (Remove bottom cover). B. Pressure Relief Valve. C. Pressure Gauge. LEAK TEST PROCEDURE: 1. Heat kettle until unit cycles off. 2. Shut off power to the kettle at the fused disconnect switch.
  • Page 22: Diagnostic Guide

    DIAGNOSTIC GUIDE This section contains servicing information intended for use by Authorized Service Personnel. NOTE 1: If Fault Isolation Procedure is required, be sure to start at step #1. NOTE 2: On table type kettles the entire control mounting panel may be removed from kettle control housing for easier troubleshooting and parts replacement.
  • Page 23 Measure continuity of ON/OFF switch/ temperature control. Is it operating properly? Unplug control box and measure the resistance across potentiometer. Is it approximately 0 ohms at maximum setting and 50,000 ohms at minimum? Remove edge connector from control box. While kettle is cold or thermistor is removed and allowed to cool, measure the resistance between edge connector’s pins #2 and #7.
  • Page 24 Remove kettle thermistor and allow to cool. Remove edge connector from control box. Test resistance across edge connector's pins #2 and #7. Is it approximately 100,000 ohms? Turn the potentiometer on the control box clockwise to increase the maximum operating temperature. Does the kettle now achieve maximum operating pressure of 30-35 psi in an empty kettle? C/ Problem: Kettle is overheating.
  • Page 25: Wiring Diagram

    WIRING DIAGRAM 3 Gallon Kettles 200-240v Single Phase Only 380-480v Single Phase Only...
  • Page 26 WIRING DIAGRAM 6-20 Gallon 200-240v 380-600v...
  • Page 27 Symbol Legend (page 1 of 2) ✔ ✔ ❐ English ❐ French ❐ Spanish ❐ Italian ❐ German ❐ Chinese-Simplified ❐ Chinese-Traditional RISK OF ELECTRICAL SHOCK DANGER DE SECOUSSE ÉLECTRIQUE PELIGRO DE ELECTROCHOQUE PERICOLO DI SCOSSA STROMSCHLAG-GEFAHR ✔ ✔ ✔ ✔ SPLASHPROOF ANTIÉCLABOUSSURES A PRUEBA DE SALPICADURAS...
  • Page 28 Symbol Legend (page 2 of 2) ✔ ✔ ❐ English ❐ French ❐ Spanish ❐ Italian ❐ German ❐ Chinese-Simplified ❐ Chinese-Traditional AUTOMATIC TEMPERATURE CONTROL COMMANDE AUTOMATIQUE DE LA TEMPÉRATURE AJUSTE AUTOMATICO DE TEMPERATURA CONTROLLO AUTOMATICO TEMPERATURA AUTOMATISCHE TEMPERATURREGELUNG ✔ ✔ BURNER AND/OR ELEMENT ENERGIZED BRÛLEUR ET/OU ÉLÉMENT ALLUMÉ...

This manual is also suitable for:

Ket-6-tKet-12-tKet-20-tTket-3-tTket-6-tTket-12-t

Table of Contents

Save PDF