Download Print this page

Elid EL2700 User Manual

Ip-based access control system

Advertisement

Quick Links

EL2700
IP-BASED ACCESS CONTROL
SYSTEM
USER MANUAL
(REVISION 1.0.0)
ELID SDN BHD
EL2700 IP-Based Access Control System

Advertisement

loading
Need help?

Need help?

Do you have a question about the EL2700 and is the answer not in the manual?

Questions and answers

Summary of Contents for Elid EL2700

  • Page 1 EL2700 IP-BASED ACCESS CONTROL SYSTEM USER MANUAL (REVISION 1.0.0) ELID SDN BHD EL2700 IP-Based Access Control System...
  • Page 2 Table of Contents TABLE OF CONTENTS ........... 2 1. INSTALLATION............1 2. STARTUP THE CONTROLLER ......5 3. PROGRAMMING MENU ........8 4. WEB SERVER MENU INTRODUCTION ..... 41...
  • Page 3 EL2700 IP-Based Access Control System User Manual CHAPTER 1 1. INSTALLATION 1.1 SYSTEM CONFIGURATION 1.1.1 LAN Configuration EL70Y / EL70W WAN / LAN EL2700 EL2700 EL2700 EL2700 Revision 2.0...
  • Page 4 1. EL2700 can connect maximum up to 8 units of reading devices with combination of EK847, EK848, ERM845, Syris and EA45. 2. The last unit of reading device has to be terminated. 3. EL2700 can connect maximum up to 3 units of EA62 I/O board. Revision 2.0...
  • Page 5 4x4 keypad. It is only required when you cold start the controller and setting of IP EK13S Keypad address and card type. EL2700 can run normally without this board and thus it is an optional board. The standard power supply for EL2700 is Power Supply EP42S, 12V/4.2A switching power supply.
  • Page 6 EL2700 IP-Based Access Control System User Manual 1.3 JUMPER SETTING There are 2 jumpers to set at EL2700 before startup: 1. PIN 3 of JP567 (Battery shunt) The controller is shipped to you with the shunt “OFF”. You should put this to “ON”, otherwise, memory will be lost each time you turn off...
  • Page 7 “ON”, otherwise, memory will be lost each time you turn off power to the controller. When using EL2700 for the first time, use steps below to carry out a cold start in order to restore all settings and memory buffer to factory default setting.
  • Page 8 User Manual EL2700 IP-Based Access Control System 2 . 2 KEYPAD USAGE AND MENU SELECTION A(LEFT) and D(RIGHT) To scroll through main functional menus / go to next setting in sub-menu B (UP) and C (DOWN) To scroll through sub-menu...
  • Page 9 EL2700 IP-Based Access Control System User Manual MAIN DISPLAY Under normal operation, EL2700 display is showing date/time information. However, user can navigate through the main display information by using ‘C’ button. Currently, supported displays are as follows: Date and Time...
  • Page 10 EL2700 IP-Based Access Control System User Manual CHAPTER 3 3. PROGRAMMING MENU GETTING INTO PROGRAMMING MENU Press key ‘D’ , key in 6 digits master PIN when requested. Default master PIN after cold start is 123456. Enter Mstr Pin ******...
  • Page 11 EL2700 IP-Based Access Control System User Manual Trans Menu Door Menu Print Trans L.R Time Clear Trans P.L.R Card+PIN Inhibit Acc I/O Menu Cont. Swipe Output1 TZ Exit Push Buttn Output2 TZ Anti PB O/P Type Rst APB APB Rst Tmr...
  • Page 12 < > anytime to abort and return back to Time Menu. 3.3.3 Set Holiday EL2700 may be programmed to recognize holidays. During holiday, a different set of time zones may be activated. A total of 20 holidays may be preprogrammed using Set Holiday Menu as shown below: Holiday ...
  • Page 13 EL2700 IP-Based Access Control System User Manual The display above shows the cursor blinking at the month field. Any valid month value may be entered. E.g. for January, enter 01. The cursor will then jump to the Day field. Any valid value may be entered.
  • Page 14 3.3.4 Set Timer EL2700 caters for 24 sets of timers for each door where 22 sets are programmable. Each set consists of 2 pairs start time and end time. Timer 1 is pre-defined as ‘No Entry Timer’ and Timer 2 is pre-defined as ‘Free Entry Timer’.
  • Page 15 EL2700 IP-Based Access Control System User Manual Use ‘B’ and ‘C’ key to select which door to set and press <#>. The display shown as below: Timer# Door Set number (1 to 24) number (Set 1 or Set 2) Timer [D1#01-1] 00:00 →...
  • Page 16 EL2700 IP-Based Access Control System User Manual 3.3.5 Set Access Time Zone This command allows you to associate the timers, which you have programmed in Section 3.3.4 with each Access Time Zone. There are a total of 10 Access Time Zones. Each with a programmable timer for each day of the week and holiday.
  • Page 17 EL2700 IP-Based Access Control System User Manual Acc TZ (1 To 10) Door Timezone [D1#01] SUN: 01 Day of the Timer # week (1 To 24) Enter the desired timer value. These values refer to the timer settings described in Section 3.3.4 and can be any from 1 to 24.
  • Page 18 3.4.2 Set Unit Number Unit number is the identification number of controller. Since EL2700 is a four doors controller, it unit number is in sets of 4. You can only choose 1 set from 4 sets of unit number, ‘1 2 3 4’, ‘5 6 7 8’, ‘9 10 11 12’...
  • Page 19 EL2700 IP-Based Access Control System User Manual Set Netmask 255.255.000.000 Set Gateway 128.100.001.002 Port Setting Port: 04001 Please check with the network administrator on what values to set and key in these values. 3.4.4 MAC Address Display MAC Address of EL2700.
  • Page 20 EL2700 IP-Based Access Control System User Manual READER MENU 3.5.1 Reader Format Depending on the type of readers you are using, you should set to the appropriate card format. On entering this menu, the display as below appears: Reader Format ...
  • Page 21 EL2700 IP-Based Access Control System User Manual Card Number € € Card size 40 bits |€------20 bits----------€| Card offset bit |€------20 bits ---------- €| Card length bit The cursor will blink at the Offset field, you may key in the new value.
  • Page 22 EL2700 IP-Based Access Control System User Manual Key in the 8 digits serial number, ID:1 SN:12345678 once you have key in the 8-digit number. In d1 ERM845 If you want to change the serial number, you may press ‘’ key to back to the particular number to change.
  • Page 23 EL2700 IP-Based Access Control System User Manual This command is used to manually reinitiate polling mechanism for all readers, if the readers happen to be disconnected. Reader Menu Repoll All Rdr  Press <#> to execute this command or <...
  • Page 24 EL2700 IP-Based Access Control System User Manual the following display is shown: Processing… 0000000000 INST When the display back to Add Card menu, the card installation is completed. 3.6.2 Add Card with PIN On executing this command, the following display is shown: Add Card w PIN ...
  • Page 25 EL2700 IP-Based Access Control System User Manual 3.6.3 Delete Cards On executing this command, the following display is shown:- Del. Card  Door 1 You can select either to delete cards in Door 1, Door 2, Door 3 or Door 4. Press “B” or “C” Key until the desired door is displayed, then press <#>.
  • Page 26 EL2700 IP-Based Access Control System User Manual Clear DB Confirm? Press <#> to proceed with clearing card database. If you do not  wish to clear card database, press < > to return. The card database is cleared once the following display is shown:...
  • Page 27 EL2700 IP-Based Access Control System User Manual 3.7.2 Permanent Lock Release The Permanent Lock Release command is for manually keeping the door released. On entering this command, the following display will appear:- P.L.R D1:OFF D2:OFF Here, “ D1 “ refers to DOOR 1, and “ OFF “ shows that the door is NOT released.
  • Page 28 EL2700 IP-Based Access Control System User Manual 3.7.3 Card + PIN Mode The procedure for setting PIN mode is also similar to that of setting Permanent Lock Release. First, you must set the value for door 1 and door 2, then door 3 and door 4. When PIN mode is set to ON, entry requires card plus PIN.
  • Page 29 • Group Anti-Passback – In this mode, doors within local EL2700 can be grouped to form an Anti-Passback zone. Doors with the same Anti-Passback will have a common effective Anti-Passback area. EL2700 provide only two group, namely Group 1 and Group 2.
  • Page 30 EL2700 IP-Based Access Control System User Manual On executing this command, the following screen appears:- Anti PB Door 1 Press “B” or “C” Key until the desired door is displayed, then press <#>. Thereafter, the following screen will appear:- Anti PB [D1]...
  • Page 31 The PIN Only command allows you to set whether you wish to have the facility of opening the door by PIN number (without card). Every door in EL2700 allows you to predefine up to 4 such numbers that can be used to open the door.
  • Page 32 EL2700 IP-Based Access Control System User Manual  The user must press the “ ” key until the display shows “Enter Pin”, indicating that the controller is ready to read PIN number. The  display will show a “ ” symbol for each digit keyed in. When the correct number is keyed in, the door lock will be activated, and the display will show “Valid entry”.
  • Page 33 EL2700 IP-Based Access Control System User Manual The value “[D1]” refers to Door 1, and the timers associated for Sunday is shown after this. For example, to set the timers for Sunday to 01, we must key in “01 <#>”. The display will now move to Monday. Continue to set the desired timers until all eight days (Sunday through Saturday, plus holiday).
  • Page 34 EL2700 IP-Based Access Control System User Manual 3.7.14 Double Swipe Only the first transaction will trigger the lock/barrier within swiping duration. Badge the same card multiple times within swiping duration, the controller will detect the other transaction after the last valid card badge.
  • Page 35 > key to return. INPUT/OUTPUT MENU Each door in EL2700 can control 2 output points referred to as GP output #1 and GP output #2. These output points might be used, for example, to switch on buzzers, pumps, lights, air-conditioners, fans etc.
  • Page 36 EL2700 IP-Based Access Control System User Manual Output1 TZ  Door 1 You can select from Door 1 to Door 4. Press “B” or “C” Key until the desired door is displayed, then press <#>. The following display appeared. Output1 TZ [D1] ...
  • Page 37 EL2700 IP-Based Access Control System User Manual 3.9.3 Output Type If the "OUTPUT TYPE" command is selected, the screen will show: - O/P Type [D1] #1: GP Output Output point # Output type The value “D1” refer to Door 1 and the value “#1” refer to output #1.
  • Page 38 Set Mstr PIN 3.10.2 Reset Web Server Password This command allows you to reset web server password back to default value which is “elid”. This command is used if user forgot the existing password to login into EL2700 web server. System Menu SET SUCCESS! 3.11 TEST MENU...
  • Page 39 EL2700 IP-Based Access Control System User Manual If Key 1 is pressed, the Door Latch output for door 1 is switched on and the display will show: - Door1 Outp Tst  1 Door Latch If Key 2 is pressed, the Output #1 for door 1 at EA62 is switched on...
  • Page 40 EL2700 IP-Based Access Control System User Manual Sensor #1 to Sensor #4 is shown by value of “S” in HEX number presentation. You need to connect the HEX number to binary first and check the binary values against the following table:-...
  • Page 41 After the test, it will automatically return to main test menu. 3.11.5 Test Communication Test Comm This test menu can be used to test EL2700 communication port either via RS485 or LAN. RS485 Communication Test To test RS485 communication, connect the EL2700 controller to an EL70Q dan EL70S communicator via RS485 cabling.
  • Page 42 <EL2700 IP address> <EL2700 IP Port> When echo test is executed, everything typed on the keypad of the EL2700 will be sent to telnet display. Likewise, everything typed on the PC keyboard will be received and displayed on the EL2700 display.
  • Page 43 Management software, please refer to the individual software manual. To log into EL2700 Web Server, key in your controller IP at web browser, for example, ‘http://128.100.28.3/, the following screen will be prompted (Note that different version of internet browser might have different login screen): For logging on, the default user name and password is ‘elid’.
  • Page 44 EL2700 IP-Based Access Control System User Manual TIME MENU 4.1.1 Set Date & Time Click on ‘Time’ button, the controller date and time will be synchronized to PC date and time. HOME MENU Clicking on the home menu will bring up the transaction screen.
  • Page 45 EL2700 IP-Based Access Control System User Manual 4.2.1 Set Timers/Time Zones Before you want to change any setting, you must select he door to set by checking the box for the particular door. This is to confirm that which door setting you wish to change.
  • Page 46 User Manual Set Timers EL2700 caters for 24 sets of timers for each door where 22 sets are programmable. Each set consists of 2 pairs start time and end time. Timer 1 is pre-defined as ‘No Entry Timer’ and Timer 2 is pre- defined as ‘Free Entry Timer’.
  • Page 47 EL2700 IP-Based Access Control System User Manual Select Time Zone to set (3 to 10) Fill in timer for each day. (01 to 24) Select Door to set Click ‘Set Time zone’ button to save record. The new Time Zone will be updated and display at the left hand side of each box with yellow font.
  • Page 48 EL2700 IP-Based Access Control System User Manual 4.2.2 Set Holidays There are total 20 holidays in EL2700 may be preprogrammed. Each holiday consists of ‘Month’ and ‘Day’. Select number of holidays to set. Click on the date/month field and select the desired holiday date from the pop up calendar.
  • Page 49 EL2700 IP-Based Access Control System User Manual 4.2.3 Set Reader Select the reader ID for setting (1 to 8). Enter the reader’s serial number; you may obtain the serial number from the sticker at the back of reader. Assign the reader direction for each reader. (In or Out) Select the type of reader used.
  • Page 50 EL2700 IP-Based Access Control System User Manual Pulse Door Open To pulse open door, select door to unlock from ‘Door Selection’ window, then click on ‘Pulse Door Open’ button, the locking device for selected door will momentarily unlock Door Parameter...
  • Page 51 EL2700 IP-Based Access Control System User Manual Keypad door alarm To use EK847/EK848 keypad as door. left/open alarm. Push Button enable If Off, Exit Push Button will not be Functional Continuous Swipe To allow card swipe when the door is...
  • Page 52 EL2700 IP-Based Access Control System User Manual Please note that both Auto Lock Release Time Zone and Auto PIN Disable Time Zone are under same column, you can choose to set ALR TZ or APD TZ from the drop down list.
  • Page 53 EL2700 IP-Based Access Control System User Manual 4.2.5 Pin Entry Each door has available PIN records that can be configured, each must relate to an accessible Time Zone. Select the PIN set. (1 to 4) Key in the PIN number Select Time Zone Select to which door pin to be installed.
  • Page 54 EL2700 IP-Based Access Control System User Manual In this mode, doors within local Group Anti-Passback EL2700 can be grouped to form an Anti-Passback group. All doors with the same Group Anti-Passback (Group Group 2) will form an global Anti- Passback area.
  • Page 55 EL2700 IP-Based Access Control System User Manual 4.2.8 Add/Delete Card Install Card Key in the card number to install. Select Time Zone If you wish to install more than one card that in sequential number, please select ‘Batch Add’, and key in the end number.
  • Page 56 EL2700 IP-Based Access Control System User Manual Delete Card Key in the card number to be deleted. If you wish to delete more that one card that in sequential number, please make a check on the ‘Batch Delete’ check box then key in the end card number.
  • Page 57 EL2700 IP-Based Access Control System User Manual Alarm Control Arm Delay If for example, a delay of 10 seconds is set for Sensor Input #1, which is programmed as an alarm point, then when the point is armed. It will become operational 10 seconds from the time of arming.
  • Page 58 EL2700 IP-Based Access Control System User Manual Input status Each door has 4 input sensors, which can be used to trigger alarm output. Each input points can be armed or disarmed. The input will only accept alarm signal when it is armed.
  • Page 59 This command allows output to be automatically turned ON according to intended Time Zone. 4.2.10 Change Web Server Password This command is used to change the web server user ID and password for login into EL2700 web page. Default user ID and password is “elid”. Revision 2.0...
  • Page 60 EL2700 IP-Based Access Control System User Manual CARD LIST MENU r•n nunJb ezone Cards Clear Cards Card list menu allows user to list down card databases in controller. Click on ‘Get Cards’ button, the cards database for each door will be displayed on the screen.
  • Page 61 CHAPTER 5 5. TELNET INTRODUCTION This guide will only explain how to control some EL2700 function through Telnet. To log in telnet, open command prompt and key in your controller IP at command prompt, for example. “ telnet 128.100.28.3”, the the following screen will be prompted.
  • Page 62 EL2700 IP-Based Access Control System User Manual SET RESET ANTI-PASSBACK TIMER This command will allow you to set reset anti-passback at specific time. To set anti passback timer, typr “saptmr xx:xx” button. The time in 24 hour format. RESET ANTIPASSBACK ALL DOORS...
  • Page 63 EL2700 IP-Based Access Control System User Manual RESET CONTROLLER This command allow to reset the controller without need to press the actual reset button at controller. Controller will reset. MONITOR DOOR PARAMETER Lock Release Time 5.5.1 To view lock release time setting of all doors.
  • Page 64 EL2700 IP-Based Access Control System User Manual Permanent Lock Release 5.5.2 To view permanent lock release setting of doors The Permanent Lock Release command is for manually keeping the door released. On entering this command, the following display will appear.
  • Page 65 EL2700 IP-Based Access Control System User Manual Inhibit Access 5.5.4 To view inhibit mode setting of all doors. When “Inhibit Access” is set to “ON”, all valid card holders are barred from entering. For set this this setting can refer to;...
  • Page 66 EL2700 IP-Based Access Control System User Manual Push Button enable 5.5.6 To view exit pushbutton setting of each door. If “Exit Psh Bttn” is set to ON, the push button is enabled and functional. For set this this setting can refer to;...
  • Page 67 EL2700 IP-Based Access Control System User Manual Anti-passback Reset Timer 5.5.8 To view anti-passback reset timer setting. This command will allow you to set reset anti-passback at specific time. By default will reset at midnight. For set this this setting can refer to;...
  • Page 68 EL2700 IP-Based Access Control System User Manual Interlock 5.5.10 To view interlock setting of all doors. Each time the Door Sensor Input from any Interlock enabled door is activated, the Reader will not open the door even when a valid card is swiped.
  • Page 69 EL2700 IP-Based Access Control System User Manual Exit Time Zone 5.5.12 To view exit door tz setting of all door. The controller by default Exit reader not use Time Zone. Can exit when badge card at exit reader. This command will set up the exit reader to use Time Zone.
  • Page 70 EL2700 IP-Based Access Control System User Manual 5.6.2 Change Clover Customer Code Clover customer code is controller communication code. To change clover customer code, type “sccc xxxxx”. This will change the customer code. 5.6.3 Set Valid Entry Output On Mode To set valid entry output on mode.