Philips 43PUH6101/88 Service Manual page 21

Tpl16.1e chassis
Hide thumbs Also See for 43PUH6101/88:
Table of Contents

Advertisement

Service Modes, Error Codes, and Fault Finding
Main Menu
Sub-menu 1
Clear Codes
Press [OK] to clean the Error Codes
immediately
Options
OP#1-OP#8
Alignments
Warm
Normal
Cool
Store
NVM editor
NVM editor
Service Date
Upload to USB
Channel List
NVM Copy
Readable info
EDID Copy
Download from USB Channel List
NVM Copy
EDID Copy
Initialize NVM
Press [OK] to Initialize NVM
immediately
Dealer Options
Set Virgin mode
Store
How to Navigate
In the SAM menu, select menu items with the UP/DOWN
keys on the remote control transmitter. The selected item
will be indicated. When not all menu items fit on the screen,
use the UP/DOWN keys to display the next/previous menu
items.
With the "LEFT/RIGHT" keys, it is possible to:
(De) activate the selected menu item.
(De) activate the selected sub menu.
Change the value of the selected menu item.
When you press the MENU button once while in top level
SAM, the set will switch to the normal user menu (with the
SAM mode still active in the background).
Press the following key sequence on the remote control
transmitter: "062596" directly followed by the "Home/Menu"
button to switch to (do not allow the display to time out
between entries while keying the sequence).
How to Store SAM Settings
To store the settings changed in SAM mode (except the
RGB Align settings), leave the top level SAM menu by using
the POWER button on the remote control transmitter or the
television set. The mentioned exceptions must be stored
separately via the STORE button.
How to Exit SAM
Use one of the following methods:
Switch the set to STANDBY by pressing the mains button
on the remote control transmitter or the television set.
Via a standard RC-transmitter, key in "00" sequence.
Table 5-2 Factory mode overview
Default value
Item Item value
43"
0
F/W VERSION
Press OK
1
PANEL_ID
See table
2
Tuner_ID
4
3
DEMOD_TYPE
4
4
NVM ADDRESS
0
5
NVM VALUE
0
6
NVM STORE
Press OK
Sub-menu 2
e.g. "032"
R Gain
G Gain
B Gain
R Gain
G Gain
B Gain
R Gain
G Gain
B Gain
49"
55"
65"
back to div.table 6-3
4
0
2
back to
div.table
TPL16.1E LA
Description
Erases the contents of the error buffer. Select this menu item and press the MENU
RIGHT key on the remote control. The content of the error buffer is cleared.
Option code
To align the White Tone. See
paragraph
6.3 Software Alignments
description
Store the RGB value
NVM-editor will function as in the past: Address and Value
field is a decimal value via digit entry
Edit and display the applicable service data by using the displayed key pad.
To upload several settings from the TV to an USB stick
To download several settings from the USB stick to the TV
To initialize a (corrupted) NVM. Be careful, this will erase all settings.
Dealer Options
Note: When the TV is switched "off" by a power interrupt while
in SAM, the TV will show up in "normal operation mode" as
soon as the power is supplied again. The error buffer will not be
cleared.
5.1.3
Contents of the Factory mode:
Purpose
To perform extended alignments.
Specifications
Displaying and or changing Panel ID information.
Displaying and or changing Tuner ID information.
Error buffer clearing.
Various software alignment settings.
Testpattern displaying.
Public Broadcasting Service password Reset.
etc.
How to Activate the Factory mode
To activate the Factory mode, use the following method:
Press the following key sequence on the remote control
transmitter: from the "menu/home" press "1999", directly
followed by the "Back/Return" button. Do not allow the
display to time out between entries while keying the
sequence.
After entering the Factory mode, the following items are
displayed,
Description
Displays the software versions of the supplier, Flash PQ, Smart Picture, BL Dimming,
Source Meter, the Picture Quality checksum, the Dimming library, the Source meter
library, the Flash AQ, MCU and OAD software versions.
Displays and changes the Panel ID with the left and right cursor; be careful changing
this, it can result in not correct displaying the screen!
Choose demod type.
NVM address 0 to 8191, Use Item 6 to change and 7 to store the data to the correct
NVM address
Displays the value at the NVM address of item 5
Use this option to save the data of item 6 to NVM address of item 5
5.
EN 21
in the Alignments section for a detailed
2016-Sep-23

Advertisement

Table of Contents
loading

Table of Contents