Summary of Contents for Maxeon SunPower Performance SPR-P6-555-UPP
Page 1
This document includes references to Performance Series modules. These modules do not have grounding restrictions and all are compatible with high‐ efficiency transformerless inverters. Contents of this manual are subject to change without notice. For the latest version please refer to www.maxeon.com/us/PSeriesInstallGuide Maxeon Solar Technologies, Ltd. www.sunpower.maxeon.com ...
Contact Maxeon if maintenance is necessary. operations and maintenance instructions of any type, as may be amended and Save these instructions! updated from time to time at Maxeon’s sole discretion, and all national, state, and local laws, codes, ordinances, and regulations); (iii) repair or modification by someone other than an approved service technician of Maxeon; (iv) conditions ...
MAXEON SOLAR TECHNOLOGIES, LTD. Safety and Installation Instructions ‐ Document 539821 Rev B Table 1: Electrical Characteristics 4.4 Parallel Connection The modules may be combined in parallel to produce the desired current output. Voltage at Current at Open Circuit Maximum Rated Power Short Circuit Each series string or module may be required to be fused prior to combining with Module Rated Power Rated Power, Voltage Voc System Voltage Current, Isc (A) Vmpp (V) Impp (A) UL Vmax (V) other strings if the resulting maximum fuse size allowed (number of modules which can be connected in parallel and protected by one fuse) exceeds the fuse SPR‐P6‐555‐UPP 40.0 13.89 47.3 14.73 1500 rating as shown in the module datasheet and product label. Please refer to the SPR‐P6‐550‐UPP 39.7 12.85 47.1 14.68 1500 NEC Article 690 for additional fusing requirements. ...
MAXEON SOLAR TECHNOLOGIES, LTD. Safety and Installation Instructions ‐ Document 539821 Rev B 5.2 Mounting Configurations The Rearside mismatch losses are proportional to the albedo, height of the modules above ground and structure shading factor. The irradiance non‐ Modules integrated into or mounted over a roofing system must be mounted uniformity on the rearside results in mismatch generally as the albedo increases over a fire‐resistant roof covering rated for the application. Modules may be and installation height of the modules are lower to the ground. mounted at any angle, from horizontal to vertical. To reduce soiling, modules should be mounted at a minimum of 5 degrees. 5.4 Rooftop Applications for Bifacial modules Specific information on module dimensions and the location of mounting and Bifacial modules use direct, reflected or diffuse sunlight at the rearside to grounding holes is provided in Appendix. The system installer is responsible for generate additional power. Therefore, it is recommended to use bifacial modules the determination of location‐specific load requirements. installed on flat roof applications. It should be noted that watertightness is not ensured by Maxeon, therefore, if In order to maximize the bifacial gain at the rooftop applications the following water management is required, the mounting system should be designed parameters listed below should be considered: Surface Albedo accordingly. Roof Integrity Module Tilt Angle The module is only CSA Listed for use when its factory frame is fully intact. Do Module Elevation not remove or alter the module frame, and do not create additional mounting holes because doing so may compromise the integrity of the frame. Structural Backside Shading Modules may be mounted using the following methods only: ...
MAXEON SOLAR TECHNOLOGIES, LTD. Safety and Installation Instructions ‐ Document 539821 Rev B fingerprints, stains, or accumulations of dirt on the glass may be removed with ® over‐the‐counter glass cleaners (such as Windex or equivalent), or with a 3% soap‐and‐water solution. For smaller systems, wet the module glass with the solution, let it stand for five minutes, and then wet them again and use a soft sponge or seamless cloth to wipe the glass surface in a circular motion. For large systems, wet the modules with the cleaning solution, let them stand for five minutes, and then rinse them with high‐pressure water or a soft squeegee. Do not use harsh industrial‐strength cleaning materials such as scouring powder, steel wool, scrapers, blades, or other sharp instruments to clean the module glass. Use of such materials will void the product warranty. Recommended Cable Management Performance Product Line: Portrait Stringing...
Page 6
The design loads listed in this table supersede all other loads that may be defined by other 4 Rails must not be under the junc on box. par es, unless there is a formal authoriza on by Maxeon. ...
This manual is also suitable for:
Sunpower performance spr-p6-550-uppSunpower performance spr-p6-545-uppSunpower performance spr-p6-540-uppSunpower performance spr-p6-535-uppSunpower performance spr-p5-545-uppSunpower performance spr-p5-540-upp...
Show all
Need help?
Do you have a question about the SunPower Performance SPR-P6-555-UPP and is the answer not in the manual?
Questions and answers