Vega VEGAWAVE 62 Operating Instructions Manual page 30

Vibrating level switch with suspension cable for powders
Table of Contents

Advertisement

9 Supplement
Process temperature with PUR suspen-
sion cable
Process temperature with FEP suspen-
sion cable
Product density
Ʋ Standard sensitivity
Ʋ High sensitivity
Granular size
Electromechanical data
Options of the cable entry
Ʋ Cable entry
Ʋ Cable gland
Ʋ Blind plug
Ʋ Closing cap
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
Ʋ Stranded wire with end sleeve
Adjustment elements
Mode switch
Ʋ Min.
Ʋ Max.
Voltage supply
Operating voltage
Max. power consumption
Electrical protective measures
Protection rating
Altitude above sea level
Overvoltage category
Ʋ up to 2000 m (6562 ft)
Ʋ up to 5000 m (16404 ft)
Protection class
Approvals
Instruments with approvals can have different technical specifications depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded by entering the serial number of your
instrument into the search field under www.vega.com as well as in the general download area.
30
-20 ... +80 °C (-4 ... +176 °F)
-40 ... +150 °C (-40 ... +302 °F)
> 0.02 g/cm³ (0.0007 lbs/in³)
> 0.008 g/cm³ (0.0003 lbs/in³)
max. 10 mm (0.4 in)
M20 x 1.5; ½ NPT
M20 x 1.5; ½ NPT
M20 x 1.5; ½ NPT
½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
0.2 ... 1.5 mm² (AWG 24 ... 16)
Min. detection or dry run protection
Max. detection or overflow protection
20 ... 253 V AC, 50/60 Hz, 20 ... 72 V DC (at
U >60 V DC, the ambient temperature can be max.
50 °C/122 °F)
8 VA (AC), 1.5 W (DC)
IP66/IP67 (NEMA Type 4X)
up to 5000 m (16404 ft)
III
II
I
VEGAWAVE 62 • Relay (DPDT)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEGAWAVE 62 and is the answer not in the manual?

Questions and answers

Table of Contents