Appendix

To understand this appendix, you should be familiar with the "IOL_CALL" function.
A.1

IO-Link error codes

A.1.1

ISDU return error codes

S7-PCT, IOL_CALL and the IO-Link device (reader) use the frame transport layer "ISDU".
The following table lists possible ISDU return error codes. The ISDU return error codes are
not generated by the reader. You can display the error codes using the "IOL_CALL" function
block.
Error code
Error description
(hex)
8000
Command error
8011
Index not available
8012
Subindex not available
8020
Service temporarily not available
8021
Service temporarily not available.
Local control unit blocked.
8022
Service temporarily not available.
Device is busy with another task.
8023
Access denied
8030
Parameter value is outside the permitted range
8031
Parameter value is above the limit
8032
Parameter value is below the limit
8033
Parameter length exceeded
8034
Parameter not long enough
8035
Function not available
8036
Function temporarily not available
8040
Invalid parameter set
8041
Invalid parameter set
8082
Application not ready
SIMATIC RF200 IO-Link
System Manual, 03/2012, C79000-G8976-C276-01
Remedy
-
Correct index
Correct subindex
Repeat query after a waiting time
Repeat query after a waiting time
Repeat query after a waiting time
Index can only be read
Transfer the correct value
Transfer the correct value
Transfer the correct value
Check parameter length
Check parameter length
Check call parameters
Repeat query after a waiting time
Transfer correct parameter set
Transfer correct parameter set
-