E300 communication module for modbus tcp (48 pages)
Summary of Contents for HMS Networks Anybus-E300-DPV1
Page 1
ENGLISH Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS USER MANUAL SCM-1202-203 Version 1.1 Publication date 2022-03-25...
Page 2
The information in this document shall therefore not be construed as a commitment on the part of HMS Networks and is subject to change without notice. HMS Networks makes no commitment to update or keep current the information in this document.
Preface Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 1. Preface 1.1. About This Document This manual describes the installation and configuration of the E300-DPV1. For information on how to configure the E300 Electronic Overload Relay, refer to the user manual for the E300 Electronic Overload Relay.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Trademarks Safety Symbols DANGER Instructions that must be followed to avoid an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Instructions that must be followed to avoid a potential hazardous situation that, if not avoided, could result in death or serious injury.
Safety Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 2. Safety 2.1. Intended Use The intended use of this equipment is as a communication interface. The communication module allows an E300 Relay to be integrated into an automation system. The communication module has one PROFIBUS-D-SUB connector.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Preparation 3. Preparation 3.1. Recommended Cables and Connectors IMPORTANT Use only PROFIBUS approved cables and connectors. Figure 1. Straight, 45° and 90° connectors Supported versions of PROFIBUS connectors: Straight, 45° and 90° Maximum supported PROFIBUS connector width: 35 mm.
E300 Communication Module Network Information Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 3.2. E300 Communication Module Network Information Label with Serial Number and Firmware Revision. 3.3. Support and Resources For additional documentation and technical support, please visit www.anybus.com/support www.rockwellautomation.com/support. 3.4. HMS Software Applications The following HMS software applications are needed to update the CompactCom C40 NP40 Chip firmware: •...
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Installation 4. Installation 4.1. E300 Relay Modules Three modules comprise the E300 Relay. All three modules are required to make a functional overload relay. Position Module E300-DPV1 E300 Relay Control Module E300 Relay Sensing Module Page 6 of 28 SCM-1202-203 1.1...
Attach E300 Communication Module Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 4.2. Attach E300 Communication Module Procedure To attach the E300 Communication Module to the E300 Relay Control Module: 1. Pull out the locking tab located on the upper left side of the E300 Relay Control Module.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Connect to PROFIBUS Network 3. To lock the modules, push in the locking tab located on the upper left side of the E300 Relay Control Module. 4.3. Connect to PROFIBUS Network The E300 Communication Module has one PROFIBUS D-SUB connector.
Connect to Ground Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 4.4. Connect to Ground Connect the Green Wire to Functional Earth (Ground). SCM-1202-203 1.1 Page 9 of 28...
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS PROFIBUS Address Setting Via Rotary Switches 4.5. PROFIBUS Address Setting Via Rotary Switches Use the three rotary switches to select the PROFIBUS address. Rotary Switch Setting Function 000 - 125 User configured PROFIBUS address...
Verify Operation Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 5. Verify Operation 5.1. LED Guide E300 Communication Module LED Indicators LED A LED C LED D Indicator State POWER MODE - Network Status STATUS - Module Status Device off Not online/No power...
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Maintenance 6. Maintenance 6.1. Firmware Update for Host Controller Before You Begin Download Flash Magic Tool Installation Files The Flash Magic tool is needed to update the E300-DPV1 firmware. Visit www.flashmagictool.com and download the installation files for the current version of the Flash Magic tool.
Page 17
Firmware Update for Host Controller Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Start the Flash Magic tool and configure the following settings: Figure 3. Flash Magic tool firmware update a. Set Device to UART/LPC1518. b. Select a Serial Port to connect to on your PC.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Firmware Update for the CompactCom C40 NP40 Chip 6.2. Firmware Update for the CompactCom C40 NP40 Chip Before You Begin Download HMS Software Applications The following HMS software applications are needed to update the CompactCom C40 NP40 Chip firmware: •...
Page 19
Firmware Update for the CompactCom C40 NP40 Chip Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS To access the TTL pin header connector located on the E300-DPV1 PCB, remove the E300-DPV1 top lid. Figure 4. TTL pin header connector Connect a TTL-USB cable to the E300-DPV1 TTL pin header connector.
Page 20
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Firmware Update for the CompactCom C40 NP40 Chip In the Firmware Manager II: Figure 5. Firmware Manager II Manual Update Wizard a. Click File > Manual Update Wizard. b. Select Anybus CompactCom 40 and click Next.
Page 21
Firmware Update for the CompactCom C40 NP40 Chip Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 10. In the Firmware Manager II: Figure 6. Firmware Manager II update firmware a. Select the imported E300-DPV1 firmware update. b. Click Update and wait until the update is completed.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Troubleshooting 7. Troubleshooting 7.1. Additional Diagnostic information The E300 Communication Module for PROFIBUS offers additional internal diagnostic information. States and statistics describing the internal DeviceNet and CAN communication between the E300 Communication Module and the E300 Relay Control Module, as well as internal firmware versions are parts of the internal diagnostic information.
Page 23
Additional Diagnostic information Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS DeviceNet Status (Slot 4, Index 72) Byte offset Name Data Type Description Last EM read error UDINT Table 2. Most recent error code of any Explicit Message read: additional status code status code Cleared after reading.
Page 24
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Additional Diagnostic information Byte offset Name Data Type Description Bit6 = Error warning Bit7 = Bus-Off DeviceNet IO UDINT Count of occurred DeviceNet IO connection timeouts since start-up connection timeout count DeviceNet IO UDINT Count of incoming DeviceNet IO messages consumed since start-up.
Protection Trip Status Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 7.2. Protection Trip Status Procedure To Test the E300 Relay: 1. Ensure that the E300 Relay is untripped. 2. To open the trip relay contact, press the Test/Reset button for 2 seconds and then release it.
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Technical Data 8. Technical Data For complete technical specifications and regulatory compliance information, please visit www.anybus.com/support. 8.1. Technical Specifications Article identification 029300-B Communication connector 9-pin D-sub Power consumption Typical: 200 mA @ 5 VDC, Termination active Storage temperature -25 to +90 °C...
Reference Guides Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS 9. Reference Guides 9.1. Cyclic Input Data Cyclic data sent by the E300-DPV1 to the PLC. Byte Offset Datatype Read/ Write Description Also accessible via Slot Index UDINT Reserved for Logix...
Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Acyclic Data 9.3. Acyclic Data Slot Index Datatype Length in bytes Read/ Write Description USINT %TCU UINT Time to Trip UINT Time to Reset WORD Current Trip Status WORD Voltage Trip Status WORD...
Page 29
Acyclic Data Anybus-E300-DPV1 - E300 Communication Module for PROFIBUS Slot Index Datatype Length in bytes Read/ Write Description USINT Ground Trip Delay UINT Ground Fault Trip Level USINT Ground Fault Warning Delay UINT Ground Fault Warning Level USINT Ground Fault Filter...