Electrical Protection - Sanyo HIP-215NHE5 General Installation Manual

Advertisement

Electrical SpecificationsBŁ
Electrical Specification
Model
Cell Number in Series [Pieces]
Maximum Power (Pmax) [W]
Maximum Power Voltage (Vmp) [V]
Maximum Power Current (Imp) [A]
Open Circuit Voltage (Voc) [V]
Short Circuit Current (Isc) [A]
Cell Type
Maximum System Voltage [V]
Factory Installed Bypass Diode
W eight [kg]
*HIT= Hetero junction with Intrinsic Thin-layer
Note: The values in the above table are nominal.
Module wiring
> The maximum number of HIP- xxxNHE5, xxxNHE5-BO2
modules that can be wired in series is seventeen (17).
> The maximum number of HIP- C8C8C8
modules that can be wired in series is thirteen (13).
> When your PV system includes other components
(batteries, charge controllers, inverters, etc.), be sure to
follow the safety recommendations of their manufactures.
> These modules contain factory installed bypass diodes.
If these modules are incorrectly connected to each other,
the bypass diodes or cable or junction box may be
damaged.
Array Wiring
The term "array" is used to describe the assembly of
several modules on a support structure with associated
wiring.
Use copper wire that is sunlight resistant and is insulated
to withstand the maximum possible system open circuit
voltage. Check your local codes for requirements.

Electrical Protection

The HIP- xxxNHE5, -xxxNHE5-BO2,
--xxxBE11, -xxxBE11-BO2 Module complies with the
requirements of Electrical protection Class II.
If necessary, the module or array can be grounded.
Module Terminations
A junction box as terminal enclosure is equipped for
electrical connections on SANYO modules.
The HIP- xxxNHE5, -xxxNHE5-BO2, -xxxBE11, -
xxxBE11-BO2 modules are equipped with MC plugs as
terminal enclosure.
Use these MC plugs for electrical connections.
Please contact your local dealer with questions
regarding other electrical connections for modules.
HIP-205BE11, -205BE11-BO2, -200BE11, -200BE11-BO2, -195BE11,
-195BE11-BO2, -190BE11, -190BE11-BO2, -186BE11, -186BE11-BO2,
-180BE11, -180BE11-BO2 )
HIP
HIP
- 205BE11,
- 200BE11,
- 205BE11- BO2
- 200BE11- BO2
96
96
205
200
56.7
55.8
3.62
3.59
68.8
68.7
3.84
3.83
1000
1000
Yes
Yes
14
14
BE11, xxxBE11-BO2
HIP
HIP
- 195BE11,
- 190BE11,
- 195BE11- BO2
- 190BE11- BO2
96
96
195
190
55.3
54.8
3.53
3.47
68.1
67.5
3.79
3.75
HIT* (hybrid of a- Si and mono c- Si)
1000
1000
Yes
Yes
14
14
Junction box configuration and
description of terminals (for reference)
Modules equipped with one junction box contain
terminals for both positive and negative polarity, and
bypass diodes.
Two terminals are dedicated to each polarity (with the
polarity symbols engraved onto the body of the junction
box ) (see Fig3).
negative ( - )
Figure3: Configuration of
4
HIP
HIP
- 186BE11,
- 180BE11,
- 186BE11- BO2
- 180BE11- BO3
96
96
186
180
54.4
54.0
3.42
3.33
67.0
66.4
3.71
3.65
1000
1000
Yes
Yes
14
14
Cable
Connector
(MC Plug)
positive ( + )
junction box
Printed in Europe 20.10.2006