• Audible continuity • Resistance • Diode testing • 63mm jaw opening • LCD backlight • Maximum value hold • Data hold • Auto power off • Hand strap • Carrying case • Test leads OPERATOR’S MANUAL ORDER CODE: OXD-516-1725D cromwell.co.uk...
Page 2
SAFETY INFORMATION Never apply more than the rated voltage, as marked on the Clamp Meter, between the terminals or between any terminal and grounding. If the value to be measured is unknown, use the maximum measurement position and reduce the range step by step until a satisfactory reading is obtained.
Page 3
PRODUCT FEATURES (FIGURE 1) Clamp body Clamp head trigger Function keys Input port Dial function switch Clamp head Wire positioning indicators UT220 OPERATING MANUAL UT220 OPERATING MA UT220 OPERATING MANUAL UT220 OPERATING MANUAL DISPLAY SYMBOLS (FIGURE 2) Low battery indicator 1.
TECHNICAL INFORMATION General specification Liquid crystal display: Maximum display 1999. Polarity display: Auto positive and negative polarity display. Over range indication: “OL” or “-OL”. Low battery indication “ ” battery needs replacing. Sampling rate: 3 times per second Type of sensor: AC measurement current coil sensor.
Page 5
DC VOLTAGE ( ) Input impedance ≥10MW AC VOLTAGE ( ) Mean value response Input impedance ≥10MW Frequency response: 40~400Hz(≤400mV; 50~100Hz) RESISTANCE (W) CONTINUITY TEST ( DIODE TEST ( AC CURRENT ( ) Mean value response Frequency response: 50Hz~60Hz...
Page 6
9. Refrain from changing the internal wiring in the clamp ammeter to guard against damage to the meter and danger. 10. Refrain from storing or using the clamp ammeter in the explosive and flammable environment with high temperature, high humidity and strong electromagnetic field. 11 .
Page 7
9. Refrain from changing the internal wiring in the clamp ammeter to guard against damage to the meter and danger. 10. Refrain from storing or using the clamp ammeter in the explosive and flammable environment with high temperature, high humidity and strong electromagnetic field. 11 .
Page 8
and danger. 11 . Clean the clamp meter case with soft cloth and neutral detergent. To prevent causing corrosion t 8. When LCD display shows the icon " �" it is required to replace the battery in time to ensure the measurement of on-line resistance and diode or the circuit on-off measurement, the power of circuits measurement accuracy.
9. Refrain from changing the internal wiring in the clamp ammeter to guard against damage to the meter and danger. 10. Refrain from storing or using the clamp ammeter in the explosive and flammable environment with high temperature, high humidity and strong electromagnetic field. 11 .
Page 10
Attaching The Hand Strap (See Figure 11) Open the hand strap. Slide the two tabs through the tether points. Fold the tabs back over themselves and press them down firmly. Close the strap by pressing it firmly in place. Figure 11...
& specifications. Assuring the quality and performance required by all sectors of industry. OXFORD PRECISION products are fully guaranteed against faulty materials & workmanship. Should they be found to be defective, they will either be repaired or replaced free of charge (fair wear and tear and/or misuse excepted).