FAULT FINDER

If your boiler is not operating, it is suggested that you go
through the following simple checks before either calling your
installer or Worcester Heat Systems.
SYMPTOM
POSSIBLE CAUSE
Boiler does not fire and
There is no demand for heat
burner lockout lamp is
from external control
not illuminated
equipment
There is demand for heat from
external control equipment but
the boiler does fire
There is no demand for heat
from the boiler temperature
control thermostat.
The automatic reset overheat
thermostat has operated.
Manual reset overheat
thermostat has operated.
There is no electricity supply to
the boiler.
Boiler does not fire and
The boiler has attempted to fire,
burner lockout lamp is
but has gone to lockout.
illuminated
CHECK/REMEDY
• Check the programmer is programmed for
hot water and/or central heating and re-
programme if necessary.
(See programmer operating instructions).
• If the boiler is programmed for central
heating, check the room thermostat is
turned on.
• Check any other control devices fitted.
• Check the switch on the Outdoor Pack is
set in the 'Run' mode.
• Turn the temperature control knob to
maximum.
• If the boiler is hot allow time to self reset.
• Press the reset button
(See section 'High-limit thermostat).
• Check power supply is switched on.
• Check the external power supply fuse.
• Check the switch on the Outdoor Pack is
set in the 'Run' mode.
• Remove the Outdoor Pack front cover and
white front panel of the boiler casing and
depress the lockout reset button on the
burner. (See section 'Lockout'.)
• Check the level in your oil tank and
replenish if necessary.
9