  • Page 1 IWM-TX5 User manual...
  • Page 2: Packing Content

    This manual is intended to offer a basic guide to getting started with the module, but also how configuration support for advanced users. The IWM-TX5 module is developed with particular attention to ease of use and reliability in the WM-Bus system.
  • Page 3: Safety Instructions

    For more information visit www.bmeters.com. Dispose of replaced instruments and defective components in accordance with the environmental regulations in force. IWM-TX5 User Manual v1.2...
  • Page 4 Check the water supply and the 'Maximum flow rate' alarm consecutive minutes installation of the meter Continuous reverse flow higher than Check the water supply and the 'Reverse flow' alarm the set threshold installation of the meter IWM-TX5 User Manual v1.2...
  • Page 5: Installation

    INSTALLATION The installation of the IWM-TX5 module is allowed on the GSD8-I meters only. It is recommended to install the IWM-TX5 module away from metal objects or any potential radio shielding, in a place protected from tampering. The device could be configured by using the BMetering NFC Config App. The installer has the task of checking the propagation conditions of the radio signal during installation.
  • Page 6: Radio Parameters

    The configuration and setting of further parameters / thresholds can be done via NFC and its app (BMetering NFC App). An ‘Active’ field is provided in the BMetering NFC Config App that allows you to ‘force’ the radio transmission by ignoring the passage of the 5 liters. IWM-TX5 User Manual v1.2...
  • Page 7 ALARMS The IWM-TX5 module has several built-in alarm functions: Alarm Description Activation Troubleshooting Reset Radio telegram Reverse flow alarm Reverse flow detected, a flow in the The error is triggered after a continuous Check the water supply and Reset the alarm via NFC...
  • Page 8 Do not expose the battery to an extremely low pressure environment which could cause an explosion or a leak of gases or flammable liquids; Always dispose of batteries in compliance with current regulations; Always use original spare parts authorized by the manufacturer. IWM-TX5 User Manual v1.2...
  • Page 9: Technical Data

    TECHNICAL DATA Version IWM-TX5 Wireless M-BUS module Operations Operating temperature from +1°C to +55°C Storage and transport from -20°C to +70°C Connectivity Network WM-BUS Frequency bands 868 MHz Mode Security Algorithms AES-128 Hardware Co-processor cryptographic Battery life max. 10 years * Primary cell Lithium 3.0V 1.8 Ah **...
  • Page 10 Contact Info B METERS srl Via Friuli, 3 • 33050 Gonars (UD) • ITALY Tel: +39 0432 931415 +39 0432 1690412 Fax: +39 0432 992661 E-Mail (vendite/info): info@bmeters.com E-Mail (assistenza): ticket@bmeters.com Web: www.bmeters.com IWM-TX5 User Manual v1.2...