Troubleshooting: Dell PowerVault 124T DLT VS160 Autoloader User's Guide
47
EEROM Chksum Error
48
Fan Sense Motion Error
49
Offline
4A
Host Lock Prevents Eject
4B
Open Front
4C
Over Temp
TCP/IP Stack and Task Error Types
50
IP Stack Panic
51
IP Stack Memory Allocation
Error
52
IP Stack Can't Free Memory
53
Stack DTrap Occurred
Loader Task Error Types
60
Drive Init Failed
61
Drive Login Error
62
Drive Logout/Unexpected
Error
63
Drive Command Failed
64
Drive Response Timeout
65
Command Flushed From
Queue
66
Drive Manager Not In
Correct State
67
Drive Reporting Not Ready
file:///T|/htdocs/stor-sys/124T/en/124tvs16/trouble.htm[12/5/2012 10:26:08 AM]
Contact support.dell.com.
Verify that the main fan is moving freely when the unit is on.
If the previous step fails, contact
Diagnostics controlling system. No action required.
Host backup software has issued PREVENT/ALLOW MEDIUM REMOVAL command,
often called a "lock" by the host backup software.
Issue an Unlock command through the host backup software, or power
cycle the autoloader using the Operator Control Panel power button to clear
the lock setting.
All motor movement, including picker and magazine rotation, has been disabled
for safety reasons.
Verify the magazine or magazine blank is completely inserted on both the
left and right sides of the autoloader.
Replace magazine or magazine blank (try a second one if possible).
If the Random Moves test failed, see steps above for necessary actions.
If all previous steps fail, contact support.dell.com.
Verify the temperature of the autoloader inlet air is within specification.
Clear debris from all openings of the autoloader, both in front and back.
Verify that the fan is working.
If all previous steps fail, contact support.dell.com.
Verify that the autoloader is connected to the correct network.
Verify that the network is properly configured (i.e. no loop-back condition
exists).
Verify that the autoloader operates correctly when properly configured and
attached directly to a host system using a cross-over cable.
If all previous steps fail, contact support.dell.com.
Check
support.dell.com
Check the TapeAlert log for more specific drive error information. Refer to
Table 3
for recommended actions.
Power cycle the autoloader using the front panel power button and retry
the operation.
If all previous steps fail, contact support.dell.com.
support.dell.com
for PowerVault 124T firmware updates.

Advertisement