Instructions for Use
Color LCD Monitor
Important
Please read this "Instructions for Use", and "Installation Manual"
(separate volume) carefully to familiarize yourself with safe and
effective usage.
Please retain this manual for future reference.
• For monitor adjustment and settings, refer to the "Installation
Manual".

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CuratOR EX3242-3D and is the answer not in the manual?

Questions and answers

Summary of Contents for Eizo CuratOR EX3242-3D

  • Page 1 Instructions for Use Color LCD Monitor Important Please read this “Instructions for Use”, and “Installation Manual” (separate volume) carefully to familiarize yourself with safe and effective usage. Please retain this manual for future reference. • For monitor adjustment and settings, refer to the “Installation Manual”.
  • Page 2 EIZO Corporation is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO Corporation’s receipt of said information. Although every effort has been made to ensure that this manual provides up-to-date information, please note that EIZO product specifications are subject to change without notice.
  • Page 3: Precautions

    PRECAUTIONS IMPORTANT • This product has been adjusted specifically for use in the region to which it was originally shipped. If the product is used outside the region, it may not operate as specified in the specifications. • To ensure personal safety and proper maintenance, please carefully read this section and the caution statements on the monitor.
  • Page 4 If the unit is installed incorrectly, it may drop or fall over, resulting in personal injury or equipment damage. If the unit falls, disconnect the power immediately and ask your local EIZO representative for advice. Do not continue using a damaged unit. Using a damaged unit may result in fire or electric shock.
  • Page 5 WARNING Use the enclosed AC adapter. The enclosed AC adapter (AHM250PS48T) is for use with this product only. Do not use the AC adapter with other equipment. Do not use an AC adapter designed for other devices with this product. Connecting to power sources that do not match the power ratings of the AC adapter may result in fire or electric shock.
  • Page 6 CAUTION Check the operational state before use. • Begin use after ensuring that there are no problems with the displayed image. • When using multiple units, begin use after ensuring that the images are displayed appropriately. • When viewing 3D images, use 3D Polarized Eyewear, and ensure that it is possible to view 3D images before use. Securely fix cables / cords that have a fixing feature.
  • Page 7 CAUTION Do not use the 3D Polarized Glasses for any purpose other than for viewing 3D images. Doing so may result in eye damage. Periodically clean the area around the power plug and the ventilation slot of the monitor and the AC adapter.
  • Page 8: About The Monitor

    • The backlight of the LCD panel has a fixed lifetime. When the screen becomes dark or begins to flicker, please contact your local EIZO representative. • The screen may have defective pixels or a small number of light dots on the screen. This is due to the characteristics of the panel itself, and is not a malfunction of the product.
  • Page 9: Cleaning

    • If you become fatigued or experience discomfort while viewing 3D images, stop using the monitor. Cybersecurity warnings and responsibilities • Firmware update should be performed through EIZO Corporation or its distributor. • If EIZO Corporation or its distributor instructs to update the firmware, update it immediately. About the Monitor...
  • Page 10: Table Of Contents

    Contents PRECAUTIONS ............3 IMPORTANT .............. 3 About the Monitor ..........8 Indications for Use ........... 8 Precautions for Use ..........8 Cleaning ..............9 How to use the monitor comfortably ..... 9 Cybersecurity warnings and responsibilities ..9 Contents ............... 10 Chapter 1 Introduction ........
  • Page 11: Chapter 1 Introduction

    Chapter 1 Introduction 1-1. Features ● High-quality and high-resolution Ultra High Definition (UHD) • The UHD LCD display allows for display of high-quality, high-resolution medical images. • Equipped with front protection panel • LED Backlight • Optical bonding for high visibility •...
  • Page 12: Package Contents

    ● Other functions • Optimal presets (DisplayPort [LINE BY LINE], SDI [SIMUL], HDMI [LINE BY LINE], DVI [2D]) • PbyP display function Permits parallel display of two input images side by side. (2D display only) • To allow a wide color gamut, a color gamut switch function is installed according to usage. •...
  • Page 13 Front Bottom View Displays the preset menu. (PRESET) button Displays the input select menu. (INPUT) button Displays the main menu. (MENU) button Executes the function assigned to this button. Select items in the menu screen. (F1) button (F2) button (F3) button (F4) button Switches the 3D and 2D displays.
  • Page 14 Rear HDMI DisplayPort 12G-SDI 12G-SDI RS-232C (Maintenance only) 11. DC IN terminal Connects the DC OUT terminal of the AC adapter. 12. DC OUT terminal Used to supply 5V power to a peripheral. Attention • No device coming in contact with a patient may be connected to the DC OUT terminal.
  • Page 15: Chapter 2 Installation / Connection

    Chapter 2 Installation / Connection 2-1. Before Installing the Product Carefully read “PRECAUTIONS” (page 3) and always follow the instructions. When installing this product, perform thorough operational testing (of the system, cables, arms, etc.) in the environment where the product will be used. ●...
  • Page 16: Installing The Product

    2-2. Installing the Product This product should be installed using an arm or stand. Attention • When installing, do so by carefully following the information in the User's Manual about the arm or stand. • Ensure the following and select components that comply with the VESA standards. - Clearance between the screw holes: 100 mm x 100 mm, 200 mm x 200 mm - Strong enough to support the weight of the monitor unit (excluding the stand) and attachments such as cables.
  • Page 17 Using the supplied screws Thickness of arm or stand 2 mm - 4.5 mm (M4 screw / M6 screw) Arm or stand Cabinet Screw supplied with the monitor Using commercially available screws Installation fixture Cabinet Effective length 7 mm - 11 mm (M4 screw) 7 mm - 12 mm (M6 screw) Commercially available screw Chapter 2Chapter Installation / Connection...
  • Page 18: Connecting The Power Cord

    2-3. Connecting the Power Cord Attention • Turn off the monitor before connecting it. • When removing the power cord, always remove the power plug from the power outlet first. Connect the power cord to the AC IN terminal on the AC adapter. Insert the power cord all the way to the back.
  • Page 19: Connecting The Cables

    2-4. Connecting the Cables Connect the cables appropriate for the device to be used. If you connected the HDMI cable to the monitor, be sure to secure the HDMI cable with the HDMI cable holder. 1. Turn the lever of the HDMI cable holder downward. 2.
  • Page 20: Installing The Cable Cover

    2-5. Installing the Cable Cover Align the cable cover on the back of the monitor in such a way that the cables can go through the cable outlet port. Insert the cable cover tabs into the grooves in the monitor. Tighten the screws at the left and right-hand holes on the bottom side of the monitor.
  • Page 21: Chapter 3 If No Image Is Displayed

    Chapter 3 If No Image Is Displayed Problem Possible cause and remedy 1. No picture. • Check whether the power cord is connected properly. • Check whether the DC OUT terminal and the DC IN terminal are connected properly. • Turn on the power switch. •...
  • Page 22: Chapter 4 Specifications

    Chapter 4 Specifications 4-1. Specifications List Monitor LCD Panel Type Color (IPS) Backlight Size 32.0 inches (81.3 cm) Display Resolution (H x V) 3840 × 2160 Display Size (H x V) 708.5 mm × 398.5 mm Pixel Pitch 0.185 mm × 0.185 mm Display Colors 8-bit color (DVI): approx.
  • Page 23 AC adapter Power Input 100 - 240 VAC ± 10%, 50 / 60 Hz, 3.0 A Maximum Power Consumption 202 W or less Physical Specifications External dimensions 223.0 mm × 37.0 mm × 88.5 mm (W × H × D) Net Weight Approx.
  • Page 24: Displayable Input Signals (2D)

    4-2. Displayable Input Signals (2D) √: Supported - : Not Supported Vertical Scan Resolution Scan Format DisplayPort HDMI DVI-D Frequency (Hz) 640 × 480 Progressive 59.940 √ √ √ 800 × 600 Progressive 60.317 √ √ √ 1024 × 768 Progressive 60.004 √...
  • Page 25: Displayable Input Signals (3D)

    4-3. Displayable Input Signals (3D) √: Supported - : Not Supported Vertical Scan Resolution Scan Format DisplayPort HDMI DVI-D Frequency (Hz) 1920 × 1080 Progressive 60.000 √ √ √ √ 1920 × 1080 Progressive 59.940 √ √ √ √ 1920 × 1080 Interlace 60.000 √...
  • Page 26: Appendix

    Appendix Medical Standard • It is necessary to ensure that the final system is in compliance with IEC60601-1-1 requirements. • Power-supplied equipment can emit electromagnetic waves that could influence, limit or result in malfunction of the monitor. Install the equipment in a controlled environment in which such effects are avoided.
  • Page 27: Emc Information

    EMC Information The performance of the EX3242-3D ensures appropriate display of images. Intended Use Environments The EX3242-3D is intended to be used in professional healthcare facility environments such as clinics and hospitals (including use in the vicinity of high-frequency surgical equipment such as electrosurgical knives).
  • Page 28 Technical Specifications Electromagnetic emissions The EX3242-3D is intended for use in the electromagnetic environment specified below. The customer or the user of the EX3242-3D should assure that it is used in such an environment. Emission test Compliance Electromagnetic environment - Guidance RF emissions Group 1 The EX3242-3D uses RF energy only for its internal function.
  • Page 29 Electromagnetic immunity The EX3242-3D has been tested at the following compliance levels according to the testing requirements for professional healthcare facility environments defined in IEC / EN60601-1-2. Customers and users of the EX3242-3D must ensure that the EX3242-3D is used in the following environments: Immunity test Test level for Compliance level...
  • Page 30 Recommended separation distances between portable or mobile RF communication equipment and the EX3242-3D The EX3242-3D is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the EX3242-3D can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the EX3242-3D.
  • Page 31: Warning For Radio Interference

    Trade name: EIZO Model: CuratOR EX3242-3D is in conformity with Part 15 of the FCC Rules. Operation of this product is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Page 32: Declaration Of Compliance With India Rohs

    Declaration of compliance with India RoHS We, EIZO Corporation, hereby declare and guarantee that this product has been designed and manufactured in compliance with the E-Waste management rule 2016 which prohibit the inclusion of the following substances except for the exemptions listed in schedule II.
  • Page 36 中国苏州市苏州工业园区展业路 8 号中新科技工业坊 5B 1 Queens Square, Ascot Business Park, Lyndhurst Road, Ascot, Berkshire, SL5 9FE, UK Moosacherstrasse 6, Au, CH-8820 Wädenswil, Switzerland 00N0N295B1 www.eizoglobal.com IFU-EX32423D Copyright © 2022 EIZO Corporation. All rights reserved. 2nd Edition - March 31st, 2022 Printed in Japan.