T-SERIES OM - EN 1 IMPORTANT SAFETY INSTRUCTIONS 1.1 General SAVE THESE INSTRUCTIONS. This manual contains important safety instructions for the T-Series Movable Charger, that shall be followed during installation, operation and maintenance of the unit. Items in the manual that require particular attention in order to minimize damage and harm are indicated with the below symbols.
T-SERIES OM - EN Warning! Never disconnect the T-Series Movable Charger from the mains power supply while charging. The unit must be always switched to "0" (OFF) prior to disconnection of the mains power supply. Caution! Use caution when moving the equipment. The device weight is approximately 135 kg, depending on the configuration.
T-SERIES OM - EN The cable, plugs and other electric devices may be installed or replaced only by an authorized electrician. In case of any abnormal behavior of the equipment, such as smoke coming from the CPU during normal use, stop the use instantly, turn the charger off and contact a MANUFACTURER service representative to arrange an inspection.
T-SERIES OM - EN 1.5 Environment The device shall be installed in a location whereas the ingress protection (IP) classification and ambient operating conditions are within the limits to that of the device. Do not expose the device to high temperatures, as this may cause damage to the device.
T-SERIES OM - EN 2 INTRODUCTION 2.1 Disclaimer on products and services Disclaimer While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions.
T-SERIES OM - EN 3 INSTALLATION This section describes how to take the T-Series Movable Charger into use. Refer to the Chapter "Technical data" for the power supply requirements. Table 2. Connect the T-Series Movable Charger to the power supply outlet.
T-SERIES OM - EN 3.1 Fixed installation (optional) The T-Series Movable Charger can be fixed in place by securing it with bolts to a mounting pad or other suitable fixing surface. The fixed installation requires the removal of the wheels. Site-specific variations in the fixing method may occur. Ensure that the installation surface is suitable for drilling and bolt fixing, or that it is otherwise prepared for the fixed installation.
Page 11
T-SERIES OM - EN Mark the fixing hole locations on the mounting surface. Move T-Series Movable Charger aside before drilling. Drill the fixing holes to the mounting surface. The hole depth and diameter depend on the fixing accessory dimensions. The distance between the holes is 350 mm.
Click "Log in". Note! Do not touch anything on device configuration page. Go to menu (button on left side of kempower text) and network config page. There should be nothing enabled. Enable Wi-Fi and scan network. Type in your password.
Page 13
T-SERIES OM - EN Press save and connection to the cloud is established. Disable all other. Enable legacy modem. Press "save". Note! Network status is not currently in use. 11/11/2021 1.06...
T-SERIES OM - EN 4 DEVICE The T-Series Movable Chargers are movable and modular charging solutions for commercial use. They can be used for charging passenger cars as well as other compatible machinery. Due to the modular design along with replaceable power modules and charging connectors, the same T-Series Movable Charger can be customized to provide the best possible charging result according to your specific preferences and needs.
T-SERIES OM - EN 4.1 Main parts Charging connectors * RFID reader (RFID = Radio Frequency Identification) Function button 7" touch screen "1"/"0" (ON/OFF) start switch Charge level indicator ** Rear support Front support Rating plate Figure 1. Main parts of the T-Series Movable Charger. Charge level indicator logic: 11/11/2021 1.06...
T-SERIES OM - EN LEDs are green: the charger is ready to charge LEDs are blue: charging operation ongoing LEDs are red: an alarm is active. 4.2 Identification Serial number Serial number of the device is marked on the rating plate or in another distinctive location on the device.
T-SERIES OM - EN 5 OPERATION This section describes how to start using the T-Series Movable Charger once the installation and initial setup are completed. For using the charging device, follow the device's on-screen instructions. Refer to the "Installation" section for starting up the T-Series Movable Charger. Start-up and charging of the T-Series Movable Charger.
Page 18
T-SERIES OM - EN Start-up Turn on the charging function, by turning operation switch to “1” (ON) position. Charging Ensure that you have read and understood also the instructions of the vehicle to be charged. Select the correct charging connector type. Refer to chapter “Parts"...
Page 19
T-SERIES OM - EN When the unit is not to be used for longer period of time, the operator may turn operation switch from "1" (ON) to "0" (OFF) to have it on safe standby. The charger is still accessible via the ChargEye Backend for e.g.
T-SERIES OM - EN 6 TROUBLESHOOTING See maintenance manuals for more information regarding troubleshooting. Figure 4. The charger display shows the error codes that help your service partner to fix the problem. These Error codes are also available in ChargEye back-end. 11/11/2021 1.06...
T-SERIES OM - EN 7 MAINTENANCE 7.1 General maintenance Follow these maintenance procedures to maintain the proper function of the charging system: Check that all covers and components are intact. Check all the cables and connectors. Do not use them if they are damaged and contact MANUFACTURER service for replacements.
T-SERIES OM - EN 8 TECHNICAL DATA Technical data. Table 5. 11/11/2021 1.06...
Page 23
T-SERIES OM - EN Feature Description Value Input AC power connection 3~, 380...480 V (+/-10%) Nominal input current 63 A Input frequency 50...60 Hz Power factor (@ full load) 0.94 Efficiency 94% @ nominal output power Output Maximum output power 40 kW (or 2x20 kW in simultaneous dual charging) Maximum output current (@ 500 V)
Page 24
T-SERIES OM - EN Standards Electrical safety IEC 61851-1, -23 Electromagnetic compatibility (EMC) IEC 61851-21-2 * The total weight of the T-Series Movable Charger includes the power module weight (43 kg). ** RFID = Radio Frequency Identification. Figure 5. Overall dimensions. Figure 6.
T-SERIES OM - EN 9 GLOSSARY AC = Alternative Current CPU = Charging Power Unit DC = Direct Current PCB = Printed circuit boards QR-code = Quick response code RFID = Radio-frequency identification SOC = State Of Charge – battery’s charging level UI = User interface 11/11/2021 1.06...
Need help?
Do you have a question about the T-Serie and is the answer not in the manual?
Questions and answers