FIEDLER H40 User Manual

Hydro logger small telemetry station

Advertisement

Quick Links

H40
HYDRO LOGGER
user manual version 1.01-E
Small telemetry station

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H40 and is the answer not in the manual?

Questions and answers

Summary of Contents for FIEDLER H40

  • Page 1 HYDRO LOGGER user manual version 1.01-E Small telemetry station...
  • Page 2 Hydro Logger H40 User manual FIEDLER electronics for ecology...
  • Page 3: Table Of Contents

    Hydro Logger H40 User manual CONTENT USE OF H40 1.1. GPRS UTOMATIC DATA COLLECTION VIA NETWORK BASIC DESCRIPTION 2.1. VERVIEW OF PROGRAM PROCEDURES AND FUNCTIONS 2.1. ECHANICAL DESIGN 2.2. OMMUNICATION 2.3. OWER SUPPLY SYSTEM INSTALLATION 3.1. ECHANICAL POSITIONING OF THE TELEMETRY ASSEMBLY 3.2.
  • Page 4: Use Of H40

    Hydro Logger H40 User manual Use of H40 HydroLoggers H40 are suitable for building monitoring net- works in the water industry, for monitoring surface and ground- water levels, in environmental monitoring projects and in many other similar applications where the small size of the instru- ment, its robust design and the long life of the power batteries are advantageous.
  • Page 5: Automatic Data Collection Via Gprs Network

    ACTIVE STATIONS SYSTEM FIEDLER telemetry stations are characterized by long battery life and very low operating costs with regular data transmission to the server. This has been achieved by a system of active stations and a passive server: ▪...
  • Page 6 Hydro Logger H40 User manual ▪ automatic sending of e-mails to preset addresses after meeting the set condi- tions (exceeding or dropping of the measured value over the set limits, switching on/off of the binary channel, error conditions, ...). PARAMETERIZATION OF THE STATION REMOTELY A special server service allows you to change the settings of the station parameters remotely over the Internet and GSM/GPRS network via the MOST program.
  • Page 7: Basic Description

    E c o n o m i c a l The H40 operates in a power saving mode, in which the instrument is hibernated most o p e r a t i n g m o d e of the time and only wakes up and takes measurements at the set archiving interval.
  • Page 8: Overview Of Program Procedures And Functions

    The following overview briefly summarizes the programming procedures and functions contained in the H40 station FW, which are fully available to the station users during its parameterization and setup. Most of these functions will be described in detail in the "Setup"...
  • Page 9: Mechanical Design

    User manual 2.1. Mechanical design The Hydro-Logger H40 is housed in a cylindrical stainless steel housing with a diameter of 40 mm, which is terminated on one side with a K2 connector for connecting the sensor and on the opposite side with a K1 communication connector for connecting a PC (lap- top).
  • Page 10: Communication

    H40 station. The MOST program is also used to archive the current station parameter file and to modify this file. A special server function can transfer the parameter file from the server via GSM/GPRS data net- work to the H40G station even remotely.
  • Page 11: Power Supply System

    User manual 2.3. Power supply system The Hydro-Logger H40 is powered by a lithium battery block, which guarantees many years of operation of the device even when the measured data is transmitted to the server via GSM/GPRS network on a daily basis. The instrument is supplied with an in-...
  • Page 12: Installation

    M e a s u r i n g The measuring set H40(G) + water level and a s s e m b l i e s a n d temperature sensor TSH22 is usually sup-...
  • Page 13: T O Insert Asim Card

    Hydro Logger H40 User manual 3.2. To insert a SIM card The station manufacturer has long been lending its own SIM cards to its products for a low monthly fee, which includes 1 MB of free data/month. The Hydro Logger H40G can therefore be supplied with an already inserted SIM card.
  • Page 14: Gsm Modem Operational Status Signalling

    3.4. Antenna and its location The Hydro Logger H40 comes with a small GSM 1dB antenna that connects to an SMA connector. G S M f i e l d i n t e n s i t y Reliable GPRS and SMS communication requires a GSM field strength of at least 8 on a scale of 0 to 31 at the antenna location.
  • Page 15 Hydro Logger H40 User manual M e t a l e n c l o s e d When installing the station outdoors, it is o b j e c t s often the case that the station is placed in...
  • Page 16 Hydro Logger H40 User manual GSM FIELD STRENGTH DETECTION USING MOST When installing the station, it is advisable to place its antenna in the place with the high- est GSM field strength. The modem in the station converts the current measured field strength into a number on a scale from 0 to 30 (the higher the number, the better the location for the antenna).
  • Page 17: Connecting Sensors And Transducers

    The connector connection limits the number of sensors that can be connected to the H40 and requires the addition of a cable from the sensor to the K2 connector. On the other hand, the connector connection simplifies and speeds up the installation as well as the possible servicing and calibration of the con- nected sensor or measuring probe.
  • Page 18: Power Supply For Connected Sensors And Transducers

    Hydro Logger H40 User manual 3.5.2. Power supply for connected sensors and transducers + U n a p In addition to the inputs, the K2 connector contains tubes for powering connected probes and sensors. The +Unap supply voltage (pin 1) is only briefly switched on during the measurement period.
  • Page 19: Parameter Settings

    You can start the data communication immediately by sending an SMS message in the form: HESLO, dial0 to the station's phone number (this requires that the station's H40 modem is switched on at the time of sending the SMS). FIEDLER...
  • Page 20: Basic Parameters

    Hydro Logger H40 User manual 4.2. Basic parameters A group of basic parameters for setting station identification, measurement frequency, supply voltage control, data archiving and station communication with sensors Optimal AD converter The unit places the parameters name tag at the be- ginning of the sent SMS and in the data file.
  • Page 21: Archiving

    4 - 20 mA signal. The typical rise time of these sensors ranges from 20 to 50 s, and although their use in conjunction with the H40 station is not optimal, they are often connected to these stations (river level monitoring).
  • Page 22: Analog Channel Settings

    User manual 4.3. Analog channel settings Analog channels form the basic structure of the recording part of the H40 station. The analogue or pulse signals are measured, converted to the measured physical quantity and stored in memory in the selected units of measurement. Free channels can also be occupied by a value calculated from the values on the occupied channels (sum, differ- ence and special functions).
  • Page 23 This parameter determines which terminals will be used to connect the sensor. As men- tioned, the H40 station has one pulse input PV1 and one current analog input AV1. R S 4 8 5 - a d d r e s s a n d...
  • Page 24 Hydro Logger H40 User manual A d d r e s s e s a n d m e a s u r e m e n t Type Measured quantity c h a n n e l s o f...
  • Page 25: Archiving

    "Basic parameters" and is usually set to 10 min). Less important quantities can therefore be recorded at a longer interval (e.g. 1 h), thus saving both the data memory of the H40 and the time required to transfer the measured data to the server.
  • Page 26 Archiving Interval for each recording channel. A v e r a g e d v a l u e The H40 station performs one measurement on all set channels at the interval specified s t o r a g e by the Basic Archiving Interval parameter.
  • Page 27: Advanced Parameters

    Hydro Logger H40 User manual The overlimit interval is specified in minutes and cannot be greater than the value of the base Archiving Interval. Fig. 1Detailed record of the measurand using the Over-Limit Archiving Interval. Note: The trigger condition for going to the "Over Limit Interval" archiving of a given channel can be a Limit or Gradient alarm on the channel itself, or a Limit or Gradient alarm on any other channel.
  • Page 28 Hydro Logger H40 User manual This parameter is set for probes with current output, where the parameter value corre- sponds to the maximum possible measuring range of the probe. Therefore, for a pres- sure probe with a measuring range of 0 to 6 m of water column (corresponding to an output current of 4 to 20 mA), set the parameter Max.
  • Page 29: Control Channels

    User manual 4.4. Control channels The Hydro Logger H40 contains 7 control channels K9 to K15 that monitor the operat- ing parameters of the instrument such as the capacity of the power battery, the temper- ature and humidity inside the instrument or the current draw of connected sensors and probes.
  • Page 30: Gsm Parameters

    Hydro Logger H40 User manual 4.5. GSM parameters This tab contains parameters related to SMS communication, including access to SMS phonebook settings. Password for query Depending on the SIM SMS (made from card you are using, se- query codes) lect the operator and card type from the list.
  • Page 31: Sms Communication

    Hydro Logger H40 User manual 4.6. SMS communication 4.6.1. List of authorised persons The basic settings of the GSM parameters include the creation of a list of persons to whose mobile phones warning or informative messages should be sent. The window with the phone list opens after pressing the "Phone list"...
  • Page 32: Inquiry Sms

    Hydro Logger H40 User manual INFORMATIVE SMS SENT REGULARLY To activate the regular sending of informative SMS messages, select the recipient in the parameters window called "Automatically send". This drop-down parameter will offer all preset recipients from the phonebook, including groups.
  • Page 33: Special Characters Inserted In Sms Text

    Hydro Logger H40 User manual device responds to the received INFO query with a message composed according to the codes contained in the control line. LIST OF QUERY AND CONTROL CODES Station H40G does not distinguish between upper and lower case...
  • Page 34: Control Sms Incoming

    Hydro Logger H40 User manual 4.7.4. Control SMS incoming The Hydro Logger H40G does not contain any relays, therefore, unlike the H7 or M4016- G3, the number of control SMS is severely limited. In fact, it is only a command to im- mediately send the measured data to a server on the Internet.
  • Page 35: Warning And Control Sms

    Hydro Logger H40 User manual 4.8. Warning and control SMS Automatic sending of a preset warning or control SMS can be triggered not only by ex- ceeding the preset limit value on the measuring channel, but also by a change in the state of the binary channel, an error in the measuring signal, activation or deactivation of an alarm on the channel, etc.
  • Page 36 Hydro Logger H40 User manual PARAMETERS SETTINGS The adjacent image shows an expanded menu of activation conditions that can ultimately trigger an automatic SMS alert. However, the sending of the SMS still depends on the Delay parameter. D e l a y...
  • Page 37: Parameters For Sending Data Under Tcp/Ip Protocol

    Hydro Logger H40 User manual 4.9. Parameters for sending data under TCP/IP protocol The "GPRS" tab contains the parameters needed to set up periodic sending of archived data via GSM/GPRS network to the designated server in the Internet. Enabling GPRS...
  • Page 38: Service And Maintenance

    User manual Service and maintenance The installed H40 telemetry station requires occasional checking of the cable connection status of the measuring probe and GSM antenna. Especially when installed in the field, the cabling is stressed by weather and sunlight. Mechanical damage to the cables by various rodents often occurs.
  • Page 39: Replacing The Battery Power Pack

    The used power battery blocks can be returned to the manufacturer of the device (FIEDLER AMS s.r.o. , Lipová 1789/9, 370 05 České Budějovice), who has a contract for the take-back of used batteries. Improper disposal of used batteries could damage the environment.
  • Page 40 Lithium battery pack 3.6 V / 19 Ah (28 Ah) Current consumption Type. 6 mA, 30 uA at rest Dimensions Diameter 40 mm, length 340 mm H40 (480 mm - H40G) Weight 1100 g including batteries (1330 g - H40G) Degree of coverage...
  • Page 41 89/336/EU including their supplements and EN 61326-1:98 including its supplements. Notice The used lithium batteries can be returned by the manufacturer of the device - FIEDLER AMS s.r.o., Lipová 1789/9, 370 05 České Budějovice, which has a contract with the importer of batteries for the take-back of used batteries.
  • Page 42 Hydro Logger H40 User manual FIEDLER electronics for ecology...
  • Page 43 Warranty Card Hydro Logger H40 User manual Type : H40 _______________ Date of delivery to customer : ________________ Serial number : ________________ Date of commissioning : ________________ ..............Manufacturer / Supplier - signature The product was tested and set up correctly before being shipped from the company. Nevertheless, it may happen that during operation, defects may appear on the device that are undetectable when the product is tested by the ma- nufacturer.
  • Page 44 Hydro Logger H40 User manual TXP0150914.001 H40-V101 Producer: FIEDLER AMS s.r.o. Lipová 1789/9 307 05 České Budějovice www.fiedler.company Tel: +420 386 358 274 FIEDLER electronics for ecology...