1810 2410X PROFESSIONAL LINE DEVICE PROFESSIONAL LINE DEVICE PROFESSIONAL LINE DEVICE Mini PROFESSIONAL LINE UNIT IoT Powered Owner’s Manual This Manual Inckludes: Warranty Safety Warnings Operating Instructions Replacement Directions Troubleshooting Tips Cleaning and Maintenance Tips Pureairion Via Chiesa 61/2 - 30039 Stra (VE) Tel.
Page 2
Edition: April 2021 All reproduction rights of this manual are reserved to Pureairion, even partial reproduction is prohibited. The descriptions and illustrations refer to the specific product in question, Pureairion reserves the right to make any changes it deems appropriate to series production at any time.
Page 3
WARRANTY SHU gives you the following limited warranty for this product only if it was originally purchased directly from SHU or an SHU Authorized Retail Dealer. SHU will repair or replace, free of charge, to the original purchaser, any part that is found to be defective in material or workmanship within three (3) years of the date of purchase.
Table of Contents Introduction............5 4 Transport and handling........14 1.1 Generality............5 4.1Lifting and transport...........14 1.2 General information on the use of the sanitizer...6 4.2 Storage..............14 1.3 General precautions regarding product use..6 Installation and Use..........14 Presentation............7 5.1 Preparing the area for the user......14 2.1 Intended use............7 5.2 Power supply.............15 2.2 Identification plate..........7...
CONTACT OUR ASSISTANCE SERVICE TO OBTAIN THE NECESSARY CLARIFICATIONS. 1.1 GENERALITY This instruction manual refers to the SHU 610 - 1810 - 2410X purier: YEAR OF CONSTRUCTION: 2021 This manual contains the main information indicated in the index, is an integral part of the product and must be kept with care until the nal dismantling of the product itself in order to allow reference to future updates.
1 Introduction 1.2 GENERAL INFORMATION ON THE USE OF THE SANITIZER This manual has been created in order to provide the user with a general knowledge of the product and the maintenance instructions deemed necessary for its proper functioning. Before proceeding with installation, maintenance and repairs, read the Manual carefully, it contains all the information necessary for the correct use of the product and avoid injuries.
2.4 “TECHNICAL DATA” and in compliance with the operating principle. The sanitizers of the SHU 610 - 1810 - 2410X series: They are designed for operation in support of a shelf or furniture at a minimum height of 1 meter from the oor, or with wall bracketing, paying attention to the power cable that does not constitute...
Using a broad spectrum of UV light, it is possible to obtain the same oxidant and ionizing benets that are found in nature, created by the sun. SHU 610/1810/2410X is an efcient and environmentally friendly air and surface purication system that requires only 9 Watts of electricity to operate, instead of hundreds of Watts like other products in the category.
Page 9
2 Presentation This portable unit allows the sanitization of environments such as: warehouses / sheds, salons, gyms, restaurants and longe bar, kennels, work sites, deposits of paint (only areas not exposed directly to the evaporation of solvents - do WARNING Risk of re and / or explosion), areas with strong odor smoke, morgues and areas of cremation, reclamation of food deposits, fruit and vegetables in post-harvest cells, slaughterhouses, cheese...
2 Presentation 2.4 SPECIFICATIONS Product Name: SHU 610 SHU 1810 SHU 2410X Model Number: SHU 610 SHU 1810 SHU 2410X EAN/item 8055271902784 8055271902852 8055271902920 Dimensions (LxPxH cm) Without packaging: 10x15x25 Without packaging 10x15x25 Without packaging 10x15x25 With packaging: 16x24x32 With packaging: 16x24x32...
3 Dangers and protections 3.1 PROHIBITED USES AND CONTRAINDICATIONS The product must be used for the uses foreseen by the manufacturer. See chapter 2 In particular, it is forbidden to use the product even partially: · Without protections and / or with the safety devices deactivated, damaged or missing; ·...
3 Dangers and protections TO DEROGATE FROM THE ABOVE, A SPECIFIC DECLARATION, WRITTEN BY THE COMPANY PUREAIRION SRL CAUTION ANY MODIFICATION NOT AUTHORIZED BY THE MANUFACTURER, WHICH ALTERS THE FUNCTIONALITIES PROVIDED BY MODIFYING THE RISKS AND/OR GENERATING ADDITIONAL ONES, WILL BE FULL LIABILITY OF THOSE WHO PERFORM THEM. SUCH MODIFICATIONS, IF CARRIED OUT WITHOUT THE MANUFACTURER'S AUTHORIZATION, WILL ALSO VOID ANY FORM OF WARRANTY ISSUED AND WILL INVALIDATE THE DECLARATION OF CONFORMITY PROVIDED FOR BY THE EC DIRECTIVE.
Page 13
3 Dangers and protections Always follow the basic precautions during operation of electrical equipment. DANGER: To reduce the risk of re, electric shock, property damage, or personal injury: Do not use outdoors / outdoors, in humid areas or on wet surfaces; Do not touch the plug or the appliance with wet hands;...
4 Transport and handling of the product 4.1 LIFTING AND TRANSPORT The lifting and transport of the single product is manual, due to its low weight. 4.2 STORAGE If the product is to be stored during periods of inactivity, it is recommended to store it in a covered area, which allows it to be protected from bad weather, and in an environment free from particular aggressive chemical agents.
5.4 ELECTRIC VOLTAGE SHU 610 - 1810 - 2410X is powered with a portable DC 24 V power adapter with a nominal input voltage of 100-240 VAC and a 1.80 m power cord. The adapter is equipped with a power cable of 1.50 m. Detachable and interchangeable, to meet any needs.
5.5 USE OF THE SYSTEM WITH SMART DEVICES The SHU 610 - 1810 - 2410X devices are already set up for Smart control: they can be inserted in the Rialto Active system produced by Astrel Group srl or they can be associated with a Voice Assistant (eg Amazon Alexa) equipped with a ZigBee Gateway HA inside.
Page 17
EkkO Flush model from the device list, then the EkkO 1R model follow the procedure proposed by the Application. The stimulation of the SHU 610 - 1810 - 2410X device in the pairing phase is performed by pressing the power button 6 times the sanitizer device will appear in the device list.
Page 18
The Rialto Active system can also be associated with Google Home and Amazon Alexa voice assistants. In this way it is possible to control the functioning of the SHU 610 - 1810 - 2410X both via App and voice command.
Page 19
5.5.3 USE OF VOICE COMMANDS The SHU 610 - 1810 - 2410X device, following its direct association with a voice assistant or the RialtoActive-Voice Assistant association, can also be controlled by voice commands. The basic voice commands are dictated to the assistant following a precise syntax.
5.6 POSITIONING ON THE WALL Remove your SHU from the box Remove the wall brackets from the box Remove the 4 screws from one of the 2 panels (of your choice) from the health unit as shown in the photo page 20...
Page 21
Place the brackets in correspondence with the holes and fix them with the screws removed previously Place the sanitizer on the wall with the brackets assembled previously and level it, position it at least 1.50 meters from the floor. page 21...
Page 22
Mark the position for the plugs with a pencil or marker through the holes on the brackets make the holes with an 8 mm wall drill insert the wall plugs you find in the box of the brackets page 22...
Page 23
Insert the screws using a screwdriver or an electric screwdriver as shown in the photo once the sanitizer is installed to the wall, you can turn it on page 23...
6 Maintenance and cleaning Ordinary maintenance procedure One year after the rst start-up, routine maintenance must be carried out. This operation requires the intervention of a qualied maintenance technician exclusively from SHU specialized centers, so contact a SHU distributor in your area or call customer service. Pureairion - Via Chiesa 61/2 - 30039 Stra (VE) Italy Tel.
8 Scrapping and disposal A complete overhaul of the product is possible and recommended, exclusively by the manufacturer or CAT, after 3 years of use or max 25,000 hours of operation. If the conditions of the product do not allow regeneration or use (assessment by the manufacturer), it must be replaced.
Page 26
pure Producted by www.pureairion.com - Via Chiesa, 61/2 - 30039 Stra -ve- tel. +39 049.099 8324 - fax +39 049.099 8448...