Operation & Maintenance Manual FUME BOSS READ AND SAVE THESE INSTRUCTIONS Visit our Website for more information on this product www.fumeboss.com 984 Farewell St S, Unit #3 Oshawa, ON L1H 6N6 Tel: (416) 276-9211 | info@ccmechanical.ca...
SECTION 1 - SAFETY PRECAUTIONS OF FUME & DUST EXTRACTION/COLLECTION This manual contains specific cautionary statements related to worker safety. READ To protect yourself and others, read this manual thoroughly and follow as directed BEFORE before use. Not all hazards of fume & dust control are listed in this manual, and no hazards related to welding, cutting, grinding, painting, deburring or other applications are listed.
Never use or install equipment where the potential for combustible fumes or dusts are present without a fire/explosion protection system. • If you are unsure if the product you purchased is correct for your application, call Fume Boss at (416) 276-9211. 1.5 Safety Stickers •...
FUME BOSS with articulated capture arm FB-800-015N1 2.4 Filter Specifications Filter Description Stage Part # Filter Area (sq. ft.) Reusable Efficiency Nanofiber Filter Primary FB-800-14NF MERV 15 For information on inspecting and cleaning filter, or purchasing replacement filters, contact Fume Boss at (416) 276-9211...
SECTION 3 - PRE-INSTALLATION 3.1 To Setup or Install Safely • Do not place unit near flammables or combustible surface. Refer to SECTION 2: Specifications, to know the electrical requirements of the unit • you are installing and ensure adequate input power that is properly sized, rated, and protected.
• Do not use product without first confirming if a Spark Arrestor is required and installed for the type of dust, or fumes you are extracting and/or collection. If you are unsure, call a Fume Boss representative at (416) 276-9211 4.2 Controls •...
4.4 Principles of Operation This product is designed to capture and clean smoke and dust from medium & heavy duty welding, soldering, and grinding applications. When operating, air is drawn in to the nozzle, passes through the 6” diameter hose, then through the air cleaner’s filtration system, and is exhausted through the rear discharge.
SECTION 5 - MAINTENANCE & TROUBLESHOOTING 5.1 To Maintain this Product Safely • Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. • Do not breathe the dust collected from product while changing/cleaning filters or performing maintenance on this product.
5.3 Routine Maintenance Schedule The manufacturer recommends the following routine maintenance based on light-duty use in normal operating conditions. Service more frequently if the unit is used in severe conditions. Frecuency Manual Reference Pre-Use • Perform pre-use checklist to ensure operating correctly. Clean Filter 1.
5.5 Troubleshooting Procedure Turn Unit Call for Service Check Leads at Motor (416) 276-9211 INTERMITTENTLY Input Power Operating Fume Boss Source Motor Air Flow Operating Restricted Check/clean Hood inlet & Capture tubes Check Leads at Replace Air Flow Unit Filter...
SECTION 6 - DECOMMISSIONING 6.1 To Decommission this Product Safely • Read and understand SECTION 1: Safety Precautions and SECTION 4: Operation before maintenance. • Do not breathe the dust collected from product while changing/cleaning filters or performing maintenance on this product. •...
APPENDIX 1A - ELECTRICAL DIAGRAM MANUAL [120 VAC] Single-Phase Power ELECTRIC Disconnect power before performing any maintenance on unit, including filter inspection. The input power to this unit is high voltage, and touching any live SHOCK electrical parts can cause fatal shocks or severe burns. HAZARD Do not touch live electrical parts.
APPENDIX 2 - MAINTENANCE RECORD Fume Boss authorizes this page to be photocopied or otherwise reproduced as needed for management of maintenance records. MANUFACTURER: MODEL N° FUME BOSS SERIAL N° SERVICE LOCATION: CONTROL N° Date Description of Service Serviced By...
APPENDIX 3 - ARM-TO-BLOWER DIRECT INSTALLATION 3.1 Unpack capture arm, hood, and base Capture Arm Swivel Base STEP 1. Unpack capture arm, hood, and base. Vent Hood 3.2 Attach swivel base to mounting plate STEP 2. Attach swivel base to mounting plate. •...
• Twist and release Twist Lock Latches. • Open Rear Panel. Hardware Quantity Fume Boss Assembly Rear Panel Twist Lock Latches 4.2 Preparing for filter STEP 2. Preparing for filter. • Slide and lock the Locking Bolt in the left most position.
Page 17
4.3 Inserting filter STEP 3. Insert clean filter. Hardware Quantity Fume Boss Assembly Locking Bolt Retention Rod Handle Filter 4.4 Locking filter STEP 4. Locking filter. • Push Retention Rod to forward most position • Slide and Lock the Locking Bolt to the right most position and lock.
Page 18
4.3 Closing rear panel for filter access STEP 5. Closing rear panel. • Close Rear Panel. • Twist and release Twist Lock Latches. Quantity Hardware Fume Boss Assembly Rear Panel Twist Lock Latches...
Page 20
PARTS NUMBERS ITEM # PART # INVERTORY # DESCRIPTION FB_BASE INV-CAB-FUMEBOSS-BT-GB BASE FRAME FB_SIDE R INV-CAB-FUMEBOSS-BT-GB SIDE FRAME RIGHT FB_SIDE L INV-CAB-FUMEBOSS-BT-GB SIDE FRAME LEFT INV-CAB-FUMEBOSS-BT-GB TOP FRAME FB_TOP FB_DOOR INV-CAB-FUMEBOSS-BT-GB DOOR FB_COVER PLATE INV-CAB-FUMEBOSS-BT-GB COVER PLATE FB_CAM BRACKET INV-CAB-FUMEBOSS-BT-GB SUPPORT BRACKET 4 FB_STOP BRACKET INV-CAB-FUMEBOSS-BT-GB...
APPENDIX 6 - SAMPLE SAFETY STICKERS The machine is marked with a wet filtration safety sticker to remind the operator of safe working practices: The machine is marked with safety stickers in appropriate places to remind the operator of safe working practices.
TERMS AND CONDITIONS TO SALES ORDERS INTERPRETATION 1.1. All references to “we”, “us” or “our” herein mean Fume Boss. 1.2. All references to “you” or “your” herein mean: the “Customer” referred to herein and in the Sales Order joining these presents (such Sales Order together with any amendments, supplements and additional agreements related thereto and all annexes and schedules in respect thereof, collectively the “Sales Order”);...
Page 27
FREIGHT CLAIMS Shipments must be inspected by you upon arrival. All Units are sold ex-plant. Therefore, it is the receiver’s responsibility to file any freight claims with the carrier for obvious or concealed damages. Damaged shipments must be refused at the time of receipt.
An Absolent Group Company Visit our Website for more information on this product www.fumeboss.com 984 Farewell St S, Unit #3 Oshawa, ON L1H 6N6 Email: info@ccmechanical.ca...
Need help?
Do you have a question about the FB-800-015N1 and is the answer not in the manual?
Questions and answers