SERIES 35-703
120 VAC Microprocessor-Based
Intermittent Pilot Ignition Control
FEATURES
Safe start with DETECT-A-FLAME
technology
Custom pre-purge and inter-purge timings
Single or three trials for ignition
System diagnostic LED
Local or remote flame sensing
Automatic reset
Open board, potted or enclosure
APPLICATIONS
Commercial cooking
Gas furnaces
Unit heaters
Water heaters
Other gas-fired appliances
DESCRIPTION
The 35-703 is a 120 VAC intermittent pilot (IP) control designed
for use in all types of gas-fired appliances. The control uses a
microprocessor circuit to provide precise, repeatable timing and
operating sequences. On-board diagnostics with LED output
makes troubleshooting easy and ensures safe and efficient
operation.
Export Information (USA)
Jurisdiction: EAR
ECCN: EAR99
Agency Certifications
Recognized under the UL component program, UL
R
372. Software certified to ANSI/UL 1998. UL File
MH8817
Design Certified to ANSI Z21.20,
CAN/CSA C22.2 No. 199-M89
®
flame sensing
SPECIFICATIONS
Input Power
Input Current
Main Gas Valve
Pilot Gas Valve
Operating Temperature
Storage Temperature
Flame Sensitivity
Flame Failure Response
Flame Detector Self-check
Rate
Gas Types
Spark Rate:
Size (LxWxH)
with enclosure
Moisture Resistance
Ingress Protection
Tries for Ignition
Trial for Ignition Periods
Pre-purge and Inter-purge
Timings
1
102 to 138 VAC, 50/60 Hz
350 mA @120 VAC with main and
pilot gas valve relays energized
(control only)
1.5A max @ 120 VAC
1.5A max @ 120 VAC
-40°F to +160°F
(-40°C to +71°C)
-40°F to +185°F
(-40°C to +85°C)
µ
1.0
0.8 seconds maximum
Once per second minimum
Natural, LP, or manufactured
Remote
50/60 sparks/sec
Local
25/30 sparks/sec
5.11 x 3.55 x 2.00 inches
(12.98 x 9.02 x 5.08 cm)
Conformal coated to operate non-
condensing to 95% R.H. Module
should not be exposed to water
Not rated, protection provided by
appliance in which it is installed
One or three try versions available
15, 30, 60, 90 seconds available
0, 15, 30, 45 seconds or 4 minutes
available
F-35-703
March 2020
A minimum

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Series 35-703 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fenwal Controls Series 35-703

  • Page 1 SERIES 35-703 120 VAC Microprocessor-Based Intermittent Pilot Ignition Control F-35-703 March 2020 FEATURES ® • Safe start with DETECT-A-FLAME flame sensing technology • Custom pre-purge and inter-purge timings • Single or three trials for ignition • System diagnostic LED •...
  • Page 2: Mounting And Wiring

    SEQUENCE OF OPERATION / FLAME MOUNTING AND WIRING RECOVERY / SAFETY LOCKOUT The Series 35-703 control is not position sensitive and can be mounted vertically or horizontally. The control may be mounted Start Up - Heat Mode on any surface and fastened with #6 sheet metal screws. Secure...
  • Page 3: Troubleshooting Guide

    TROUBLESHOOTING Wiring Diagrams - 35-703 Troubleshooting Guide Symptom Recommended Actions 1. Control does not start A. Miswired B. No 120VAC at L1 C. Fuse or circuit breaker fault 120V THERMOSTAT OR CONTROL DEVICE D. Faulty control, check LED SPARK H.V. OUT for fault codes B.
  • Page 4 Flame Current Measurement Flame current is the current that passes through the flame from sensor to ground. A good burner ground that matches the control ground is critical for reliable flame sensing. LOCAL FLAME SENSE With power off, connect a DC microamp meter as shown in the figure below.
  • Page 5: Part Number Configuration

    PART NUMBER CONFIGURATION SERIES 35-703 X 0 X - X X X Configuration and Wiring Options Trial for Ignition 5 = Enclosure Quick Connect 1 = 15 Seconds 6 = Integral Standoffs Quick Connect 3 = 30 Seconds 7 = Potted...

Table of Contents