Download Print this page

Brightwin Electronics BRT LB02G Quick Start Manual

Intelligent ma v signal generator

Advertisement

Quick Links

BRIGHTWIN
Intelligent Analog 0-22mA 0-±10V Signal Generator
Technical Parameters
Terms
Current output
Current output accuracy
Current sampling resistance
Voltage output
Voltage output accuracy
Voltage output current
Operating power supply
LED display
Display mode
Adjusting mode
Power consumption
Dimension & Weight
Operating temperature
Storage temperature
Humidity
Functions Description
Terminal Code
Functions
GND
Operating power supply input 24V +
24V
Operating power supply GND-
AI+
Sink current mode 24V external
power supply input
AIO
Current signal output +
AVO
Voltage signal output +
GND
Current/volt. signal output GND-
[Mode] button:
Press once, switch between adjusting current output mode and adjusting voltage output mode
[Battery SW ON/OFF]: Battery power supply switching ON/OFF.
[Voltage] indicator: the signal generator is in voltage signal output and adjusting mode, the voltage indicator is ON.
[Current] indicator: the signal generator is in current signal output and adjusting mode, the current indicator is ON.
[MicroUSB-5V]:
USB Port power supply recommended 5V 0.5A, DO NOT use quicker charger or higher than 2A power
supply.
*
Battery recharging time recommended 4-5 hours based on power adapter used.
Battery Lamp Color
Battery capacity
www.brightwinelectronics.com
Intelligent mA V SIGNAL GENERATOR
Typical Value
0-22mA adjustable, support fast output.
0.05mA, can be calibrated, 0.5% TYP.
10-500Ω, can be short-circuit.
-10V - +10VDC adjustable, support fast output.
0.03V, can be calibrated, 0.5% TYP.
driving current <20mA, max. 100mA, have short-circuit protection
15-30V external power supply via wiring terminals; 5V, 0.5A micro-USB, etc.
4 digits, two decimal points
Current/volt. value display; 0-100% percentage display; 0-50.0Hz display, etc.
One turn: 20 x pulses, precision encoder.
External 15-30V power supply: about 4W; Micro USB 5V power supply: 0.5A/0.8A
L x W x H: 100x60x20mm, Knob height: 15mm; 105g
-20 to +45℃
-25 to +65℃
80% R.O. non-condensation
Green color
Yellow color Red Color
Fully charged
95%-50%
BRT LB02G
Note
Operating power supply terminal 24VDC
Sink current signal output: AI+ is connecte
to external 24V+, output signal via AIO to
contorl exernal current from 24V.
Source current signal output: AIO is signal
output +, GND is the common GND.
Voltage signal output: AVO is volt signal
output+, GND is the common GND.
<40% Low battery
1
Default 0-20mA, switchable
Default 0-10V, switchable
Flashing
Steady green
(Connect Micro USB)
In charging
Fully charged
info@brightwinelectronics.com
BRT LB02G

Advertisement

loading
Need help?

Need help?

Do you have a question about the BRT LB02G and is the answer not in the manual?

Questions and answers

Summary of Contents for Brightwin Electronics BRT LB02G

  • Page 1 BRIGHTWIN Intelligent mA V SIGNAL GENERATOR BRT LB02G Intelligent Analog 0-22mA 0-±10V Signal Generator BRT LB02G Technical Parameters Terms Typical Value Current output 0-22mA adjustable, support fast output. Default 0-20mA, switchable Current output accuracy 0.05mA, can be calibrated, 0.5% TYP.
  • Page 2 BRIGHTWIN Intelligent mA V SIGNAL GENERATOR BRT LB02G How to know the devices (PLC, transmitter, etc.) wring mode is source current or sink current connection? 1. Check the devices (PLC, transmitters, etc.) application diagram, if its terminal I+ is connected 24V+, its wiring mode is passive current wiring mode, if I- is connected to 24V G, its wiring mode is active current wiring.
  • Page 3 BRIGHTWIN Intelligent mA V SIGNAL GENERATOR BRT LB02G 3.6 Rotate the knob till the LED screen displays FEnd, then press the knob to complete and save the parameters setting and return to normally operating status. 3.7 In parameters setting procedures, if there are no any actions taken, the signal generator will exit parameters setting status and return to normally operating status in 10 seconds.