Trouble Condition
Power Missing
AC Missing
Battery Low
Battery Missing
Low Battery
Box Tamper
Temperature Alert
Receiver Missing
Case Tamper
Receiver Jam
Comms Fail Route1
Comms Fail Route 2
Sensor Watch Alert
Comms BUSS Trble
Default PIN Trble
Date & Time
Cabinet Tamper
Connection Trouble
Overload Condition
Zone Was In Alarm
Telco Line Fail
LAN+ Overload
COMM+ Overload
ACC+ Overload
Service Required
Memory Checksum
Phone Line In Use
Battery Trouble
Bosch Security Systems 12/14 BLCC610U
The system has detected that the AC mains supply has failed or is disconnected on the control panel.
If there is not a general power outage in your area then you should contact your security company.
The system has detected that the AC mains supply has failed or is disconnected on a power supply
module. If there is not a general power outage in your area then you should contact your security
company.
The backup battery has failed the periodic test which the system performs on a regular basis. You
should contact your security company as the battery may need replacing.
The system has detected that its backup battery has been disconnected.
The system has detected that an RF sensor has a low battery condition. You should contact your
security company as the battery may need replacing.
The system has detected that the tamper circuit on a power supply module is faulted.
The system has detected that the keypad temperature has exceeded the global temperature high
and/or temperature low settings.
The system has detected that the RF receiver is disconnected.
The system has detected that the tamper circuit on the RF receiver is faulted.
The system has registered a jamming fault from the RF receiver. This situation may preven certain
parts of your system from working correctly. You should contact your security company.
The system has failed to send reports to the primary report contact. You should contact your security
company.
The system has failed to send reports to the secondary report contact.
You should contact your security company.
The control panel has detected a zone has failed to detect a change of state within the sensor watch
period set by the installer.
The system has failed to communicate to a system device (e.g. keypad etc).
The system has detected that either the Installer PIN or User 1 PIN has not been changed from the
factory default codes. These codes should be changed immediately to prevent a security risk.
The system date and time needs to be set.
The system has detected that someone has tampered with its metal enclosure or that it has been
forced open. Inspect and contact your security company if necessary.
The system has detected that an output device (eg. external siren) has failed or has been
disconnected from the system.
The system has detected that an output has an over current condition.
A zone was previously in alarm and requires alarm memory reset to clear. Turn the area on and then
off again to clear alarm memory.
The system has detected that its telephone line has been disconnected for a minimum of 30 seconds.
The system has detected that the current load has exceeded the maximum LAN rating.
You should contact your security company.
The system has detected that the current load has exceeded it's maximum COMM+ rating.
You should contact your security company.
The system has detected that the current load has exceeded it's maximum ACCS+ rating.
You should contact your security company.
The system displays this trouble condition to remind you that a service call is due.
The system has detected an error with its internal memory.
You should contact your security company.
The system is using the phone line.
The system has detected that the Real Time Clock Module backup battery voltage is low or missing
Table 8: Control Panel Trouble Messages
Description
Solution 6000
User Guide
37