Pin assignment
Pin
Signal name
OUT
X2.1 Pin1
STOP button 1 IN
X2.1 Pin2
STOP button 1 OUT
X2.1 Pin3
STOP button 2 IN
X2.1 Pin4
STOP button 2 OUT
X2.2 Pin1
Enabling device 1 IN
X2.2 Pin2
Enabling device 1 OUT
X2.2 Pin3
Enabling device 2 IN
X2.2 Pin4
Enabling device 2 OUT
Connecting the Hand-Held Terminal
The hand-held terminal is connected to the autom
nection module IndraControl VAC 30.2. Before commissioning the hand-held
terminal, the user has to ensure that the installation and particularly the
safety devices are in good order and condition.
20. Januar 2011
Connection parameters
Parameters
The connection module IndraControl VAC30.2, including
the automatic stop button bridging, is supplied with volt-
age via X1.1 pin1 or X1.2 pin1. The connected handheld
terminal is supplied with voltage via X1.1 pin3 or X1.2
pin3. To make the handheld terminal switchable or dis-
engageable when it is plugged-in, the wire jumper be-
tween X1.2 pin1 and X1.2 pin3 has to be removed and
the switching voltage for the handheld terminal has to be
applied to X1.1 pin3 or X1.2 pin3.
For safety reasons, monitor the voltage supply for the
connection module (X1.1 pin 1, X1.2 pin 1). If this volt-
age fails, the stop button at the device is inoperative.
Page 5 of 7
Value
ation system via the con-
R911333525-AA_BPZ_DOC