9.8.5

Fault Mask

Function of the "X200 Fault Mask Power" dialog box
With the "X200 Fault Mask Power" dialog box, you specify the fault/error states to be monitored
by the SCALANCE X-200RNA and that will trigger the signaling contact. Possible fault/error
states are the absence of the power supply, power supply too low, or an interrupted connection
or an unexpected connection established to a partner device. If the signaling contact is
triggered, this causes the fault LED on the device to light up and, depending on the
configuration of the event table, can trigger a trap or an entry in the log table.
Device-related link monitoring of the ports
A SCALANCE X-200RNA provides device-related link monitoring. A link-up or link-down also
affects the message system if the SCALANCE X-200RNA was appropriately configured.
Setting of the "X200 Fault Mask Power" dialog box on the device
Optionally, the dialog box can be set using the SELECT/SET button on the SCALANCE X-200RNA.
For more detailed information, refer to the section "SELECT/SET button (Page 49)".