Page 1
Instructions for use 0423642 Model :1203 V er s i on No :C-1...
Page 2
Questions? Contact our customer care team on 08085 979 899 For tips, tricks and troubleshooting, please visit tommeetippee.com Please download the Tommee Tippee app which is available on Android and iOS app store.
Contents Quick connection guide Comfort and performance guide Parts Product description Parts Getting started Assembly Cleaning and sterilising Charging Horn sizing Using your pump On-pump controls Turning it on Aligning your nipple Starting your session Choosing your intensity and mode Automatic functions Ending your session Direct-to-feed and storage...
1. Quick connection guide If you can’t wait to get started with your new pump, here’s a handy guide to help you get the most out of it. Please download the Tomee Tippee app which is available on android and iOS app store. Use QR code to download app for iOS device Android...
Page 5
Pairing Once you’ve downloaded the Tommee Tippee app and registered your account, pairing is really simple. You will need to pair each pump independently. Follow the below instructions to pair the device. Press the power button on the top of the pump...
Getting the most out of your pump We know that in order to get the most from your pump, comfort and fit are really important. Your Tommee Tippee In-Bra Wearable pump comes with unique features designed to help. Nipple alignment guide...
Page 7
Bra adjusters Another important consideration is the fit of your pump in your bra. Too much compression can feel uncomfortable, too little can feel insecure. We’ve included bra adjusters in your pack just in case you need them. Hook them on to your nursing bra to extend the cup.
3. Parts a. Product description Your Tommee Tippee wearable breast pump comes with everything you need to prepare, pump, feed and store milk. Part Single Double 1 x 24mm horn / flange 2 x 24mm horns / flanges 1 x 28mm horn / flange 2 x 28mm horns / flanges...
4. Getting started a. Assembly Your pump arrives assembled. Please disassemble, clean and sterilise before first use. See next section for cleaning and sterilising instructions. H, I, J, G assembled H, I, J assembled H, I, J, G assembled H, I, J, G, K assembled H, I, J assembled...
Page 11
To assemble, choose your preferred horn / flange (24mm or 28mm nipple / teat diameter) and insert into the pump body (1). With the collector bottle components assembled, clip in to the bottom of the pump body (2). (A/B) Horn H, I, J, G, K assembly...
b. Cleaning and sterilising Your wearable breast pump must be cleaned and sterilised before first use. Always disassemble components before cleaning or sterilising. All of the parts intended for washing can go in the dishwasher and can be sterilised, including with UV. The pump body (F) should not be washed or sterilised.
c. Charging When the battery is low, the battery light will pulse red until charge reaches 80%, at which point it will turn solid green. When charging, the battery light will pulse red until it reaches 50%, at which point it will pulse green. The pump cannot be used whilst charging.
5. Using your pump b. On-pump controls 1. Turn on light showing white (o ine) or blue (paired) 2. Choose breast light showing on L or R side to denote breast 3. Press start/stop light showing white 4. Battery each state (solid green, red, pulsing red) 5.
b. Turning it on Once fully assembled, press the power button to turn the pump on. c. Aligning your nipple Correct nipple alignment is a really key factor in milk production, much like a deep latch in breast feeding. Your new pump includes a unique nipple alignment guiding light that makes it easy to align your nipple, even in low-light.
Once the pump is turned on and in position, press play/pause to start pumping. If you need to pause pumping at any point, press play/pause. For a more discreet and convenient user experience, use your Tommee Tippee app to play/pause. e. Choosing your intensity and mode Your wearable breast pump o ers two modes –...
The lights on the pump (nipple alignment spotlight and button lights) will automatically turn o after 1 minute during use for discretion. Press any button to re-illuminate the lights. g. Ending your session Once you have finished your session, pause and finish the cycle and follow instructions in the app to collect every last drop, leaning forward for a moment before using your finger to break the seal between pump and breast.
LED light flashes blue. You will see a pop-up appear in the Tommee Tippee app and can then add the pump. Please note you will need to do this for each pump if you have bought a pair.
Page 19
How do I upgrade my firmware? The Tommee Tippee In-Bra pump is smart which means it can evolve over time, even after you’ve purchased it. Where it results in a better experience for the consumer, we will update the app periodically.
7. Safety information • Keep components not in use out of the CLOSER TO NATURE® SLOW FLOW TEAT reach of children AND RING • Never attach to cords, ribbons, laces or For your child’s safety and health loose parts of clothing. The child can be Please read and retain the instruction strangled.
Page 21
STORAGE AND USE lead to pump failure. Washing or sterilizing the air tubes will invalidate the warranty and • Inspect before each use and pull the will damage the power unit. feeding teat in all directions. • Do not place the air tubes in a microwave or •...
Page 24
Guidance and Manufacturer’s Declaration Below cables information are provided for EMC reference. Cable Max. cable length, Shielded/unshielded Number Cable classification DC Power Line 0.5m Unshielded 1 Set DC Power (USB Cable) Important information regarding Electro Magnetic Compatibility (EMC) This electrical medical equipment needs special precautions regarding EMC and put into service according to the EMC information provided in the user manual;...
Page 25
EMI Compliance Table (Table 1) Table 1 - Emission Phenomenon Compliance Electromagnetic environment CISPR 11 RF emissions Home healthcare environment Group 1, Class B IEC 61000-3-2 Harmonic distortion Home healthcare environment Class A Voltage fluctuations IEC 61000-3-3 Home healthcare environment and flicker Compliance EMS Compliance Table (Table 2-4)
Page 26
Table 3 – Proximity fields from RF wireless communications equipment Test Immunity test levels Band frequency (MHz) (MHz) Home healthcare environment 380-390 Pulse modulation 18Hz, 27V/m 430-470 FM, ±5kHz deviation, 1kHz sine, 28V/m 704-787 Pulse modulation 217Hz, 9V/m 800-960 Pulse modulation 18Hz, 28V/m 1720 Pulse modulation 217Hz, 28V/m 1845...
Page 27
Table 4 – Input a.c. power Port Immunity test levels Basic EMC Phenomenon standard Home healthcare environment Electrical fast ±2 kV IEC 61000-4-4 transients/burst 100kHz repetition frequency Surges IEC 61000-4-5 ±0.5 kV, ±1 kV Line-to-line 3V, 0.15MHz-80MHz Conducted 6V in ISM bands and amateur radio disturbances IEC 61000-4-6 bands between 0.15MHz and 80MHz...
Page 28
Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that...
Page 29
Mayborn (UK) Ltd Mayborn House, Balliol Business Park, Newcastle Upon Tyne NE12 8EW UNITED KINGDOM Mayborn USA Inc. 1010 Washington Boulevard, 11th Floor, Stamford, CT 06901 UNITED STATES OF AMERICA EU Representative Mayborn France Sarl, 56 Rue de paris, Boulogne Billancourt, 92100 FRANCE Mayborn ANZ Pty Ltd.
Need help?
Do you have a question about the 1203 and is the answer not in the manual?