Table of Contents

Advertisement

Quick Links

User Manual
BOP xD
© 2018 ACTIA I+ME GmbH │ Ref. IR:14938
Document template: R&D/2018
ACTIA I+ME GmbH
Dresdenstrasse 17/18
D-38124 Braunschweig
Germany
Phone: + 49 (0) 531 38701-0
Fax: + 49 (0) 531 38701-88
www.ime-actia.com
1 / 92

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BOP xD and is the answer not in the manual?

Questions and answers

Summary of Contents for Actia BOP xD

  • Page 1 ACTIA I+ME GmbH Dresdenstrasse 17/18 D-38124 Braunschweig Germany Phone: + 49 (0) 531 38701-0 Fax: + 49 (0) 531 38701-88 www.ime-actia.com User Manual BOP xD 1 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938 Document template: R&D/2018...
  • Page 2 J.Schaper 19/03/2018 Screenshots J.Schaper © 21 March 2018 09:04:35 ACTIA I+ME GmbH All rights reserved. Any reproduction or distribution of this document or parts of it requires the prior written approval of ACTIA GmbH. 2 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 3: Table Of Contents

    Preparatory Measures ..................21 Installation and Mounting ................22 7.2.1 Place of Installation .................. 22 7.2.2 Installation without BOP XD system rack ............. 23 7.2.3 Installation with system racks ..............23 Preparatory Measures for the Installation ............24 7.3.1 Intended Use ................... 24 7.3.2...
  • Page 4: Substance

    12.5.1.4 Time Zone String .................. 51 12.5.1.5 Vehicle Identification ................51 12.5.1.6 Sequencing Time ................... 52 12.5.1.7 Switch-off Delay ..................52 12.5.1.8 Pre-Alarm and Post-Alarm Buffer ............. 53 12.5.1.9 Maximum Storage Time ................. 53 4 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 5 Downloading Passenger Count Data per USB Stick ........78 12.2.3 Generating the Key File using the Web Interface .......... 78 12.3 Admin ......................79 12.3.1 Data Storage Access ................. 81 Structure and Contents ..................81 5 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 6 15 A bb r ev i at i on s ................. 88 16 A pp e nd ix ................90 16.1 Optional accessories ..................90 16.2 List of Figures ....................91 16.3 List of Tables ....................92 6 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 7: General Information

    This document describes the operation of the following product: Pr od uc t N a m e: It em N o. : BO P x D AR10 0092 95/ A 7 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 8: Contact Details Of The Manufacturer

    NOTICE in writing. The warranty is provided as per the statutory requirements with the explicit repair authorisation. Within the warranty period, ACTIA I+ME GmbH remedies material and manufacturing defects in a verifiable manner and free of cost.
  • Page 9: Disclaimer

    (operator) or third parties shall void the liability for any resulting consequences. The operator and the operating personnel are liable for the proper and legal use of BOP xD video surveillance system. 9 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 10: Safety

    Pu bl i c t ran sp o rt c o mpan y a ss o ci ati on V ÖV 04. 05 .06 Table 1) Standards and guidelines 10 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 11: General Safety Instructions

     Measures and prohibitions for avoiding the hazard DANGER - Accidents, severe injuries, death Hazard type and source Possible consequences of the hazard  ... Measures and prohibitions for to avert the hazard 11 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 12 Hazard type and source Possible consequences of the hazard  ... Measures and prohibitions for to avert the hazard NOTICE A notice contains valuable tips and trick for the system user. 12 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 13: Qualified Personnel

    BOP xD video surveillance system. BOP xD video surveillance system by ACTIA may only be used for recording and evaluating video and audio data as well as information related with it in vehicles under compliance with the legislative framework. BOP xD video surveillance system by ACTIA my only be installed and put into operation by qualified personnel.
  • Page 14 BOP xD video surveillance system by ACTIA in a vehicle, the vehicle’s functionality may not be affected in any way. Especially the safety systems may not be disturbed or disabled. 14 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 15: Technical Details

    1,0G/ 5-150 Hz with the device turned off Shock load 1,5G/ Half sinus/ 11ms during operation Shock load 50G/ Half sinus/ 11ms with the device turned off MPEG4/ H.264 Recording format 15 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 16: Special Tools

    Protection class Metal housing IP 40 Service life approx. 21 years Table 2 ) BOP xD Technical Details 4.1 Special Tools If special tools are required, this is indicated by a NOTICE before the respective action. 4.2 BOP xD Pin Assignment The pin assignment is indicated in the enclosed technical datasheets.
  • Page 17: Product Overview

    IBIS data stream and GPS coordinates via an external GPS system and a CAN data bus. BOP xD is able to play videos at the same time as it is recording and storing them. This is done accurately via IBIS and/or GPS.
  • Page 18: Optional Modules And Extras

     System racks = Standard holders and 19“ plug -in rack Contact your responsible project manager or send a written inquiry for additional information. We would be happy to provide you with additional information. 18 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 19: Packaging & Disposal

    European Regulations and the German Law on Electrical and Electronic Appliances (ElektroG). Used appliances and electronic components may be disposed of at the municipal collection centres. 19 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 20: Unpacking And Disposing Of The Packaging Material

    Pull up the packaging protection above by the two notches Carefully pull the BOP xD up to take it out NOTICE Protect the device from humidity, water, acid, solvents and dust. NOTICE Do not let the device fall. 20 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 21: Mounting And Installation

    Mounting and Installation 7 Mounting and Installation Personnel The BOP xD video surveillance system by ACTIA may only be installed and commissioned by trained qualified personnel. 7.1 Preparatory Measures ATTENTION - Material damage Avoid damage, malfunctions or breakdown of the BOP xD or the vehicle.
  • Page 22: Installation And Mounting

    Good installation places are:  The roof coving above the driver  The roof coving above the front passenger seats 22 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 23: Installation Without Bop Xd System Rack

     Before departure, check whether the is firmly fixed. Should the BOP xD fall during an accident because it hasn’t been properly fixed and if it causes physical inj u- ries, consult a physician immediately Bore holes as per the boring diagram...
  • Page 24: Preparatory Measures For The Installation

    7.3 Preparatory Measures for the Installation 7.3.1 Intended Use The BOP xD video surveillance systems by ACTIA may only be used for recording and evaluating video and audio data. The related additional information in the vehicles must be observed under compliance with the legal framework.
  • Page 25: Power Supply And Data Sources

     12 VDC – 24 VDC  10A fuse (time-lag). Optional: IBIS data line, GPS signal, CAN bus data line, Ethernet network cable for the network connection with iCount and Ethernet switch. 25 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 26: Start-Up

    Start-up 8 Start-up ATTENTION - Material damage If the BOP xD configuration is wrong, there is a risk that the system will not function within the desired scope. Start-up and system modification may only be performed by respectively trained qualified personnel.
  • Page 27: Functional Description

    The data is deposited to a ring buffer (controlled either by capacity or by time). Alarm data is stored in a secure area of the ring buffer that cannot be overwritten. Figure 3) Storage capacities 27 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 28: Functions

    9.2.3 Secondary Functions The recorded data can be output on parallels connected monitors. In the event of an alarm, the alarm data is transferred automatically via an external modem (e.g. xNet). 28 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 29: Visual Indicators And Instructions

    Ignition on > remains switched off 9.4 Installing/Changing the Slide Disk The slide disk is electromagnetically locked. You can remove the slide disk, when is switched-off from the key switch. 29 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 30: Exchanging The Slide Disk

    NOTICE We recommend using a transport box by ACTIA I+ME for securely tran s- porting and storing the data storage. If necessary, contact your responsible project manager! 30 / 92 ©...
  • Page 31: Bop Standard Functions

    “Terminal 15/Ignition” signal must be wired as a high active signal to the 21-pin “I/O plug” Pin 2. A follow-up time can be set in the configuration, under [General Settings Switch-Off Delay]. 31 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 32: Recording Duration

    This is not taking audio and log data into consideration (Audio=30MB h per chan- nel) Table 6) Recording Capacity in Hours* *Values for a data stream of 1Mbit/s per camera 32 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 33: Alarm

    30 seconds. By deviation of more than 2 minutes, the system is restarted. The IBIS time correction can be set under Configuration. The time can be automatically applied to a preconfigured time which requires a restart. 33 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 34: Ibis Data

    NOTICE Various non-regular functions (e.g. File Check) can increase the start -up time. 10.10 BOP Web Interface The BOP Web Interface makes the following functions available:  Live Images 34 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 35: Error Signalling

    Error messages with exact information about the error (log files: err.txt, log.txt, log.1.txt) can be automatically uploaded to an FTP server. After that, the system sends a notification that system maintenance is necessary. 35 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 36: Passwords

    ATTENTION - Password Protection Change the passwords!  To secure the system against unauthorised access, passwords overall system should not be freely accessible. Keep the passwords in a safe place. 36 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 37: Et Wo Rk Fu N Ct Io N A L It Y

    11.3 Alarm Data Feedback An automatic Alarm Data Feedback is performed after a configurable alarm data age. This age is pre-set to 90 days. 37 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 38: Data Access From The Headquarters

    [VOut#1 control]. This makes it suitable for camera control via LAN connections, such as over a secured VPN tunnel of a router via UMTS/LTE to a server. 38 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 39: Recorded Data

    30 minutes. Using the "\cfg\HDDsstate.ini” file, you can check whether the hard drives are on and if they are accessible. 39 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 40: Automatic Ftp Upload

    The maximum length is defined by the maximum length of the “UDP datagram broadcast” packages. Th e m os t i mp o rta n t pac ka g es : ##---------------------------------------------- ##--"ALARM" rx + tx: 40 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 41 3,"BOP\n ..same data as 2,"BOP\n The "BOP identification” query is used by the BOP Reviewing Software to find devices on the local network. Via [Configuration” - “Network], set 41 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 42  "Broadcast rx mask".  Whether there should be a reaction to an ALARM event from other devices in the local network, can be turned on or off separately. 42 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 43: Web Interface

    Wait until the system starts up Open the browser Go to BOP’s IP address Figure 4) Web Interface Login Screen Enter your username and password in the authentication screen Confirm with OK 43 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 44: Homepage

     Alarm > alarm date available  Camera error > one or more cameras have experienced a malfunction  GPS coordinates > only if a GPS receiver is connected BOP xD serial number  44 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 45: Live Images

    A current version of VLC Media Player is installed! Figure 6) Live Image Camera A sequence can be saved and reviewed at a later time using the button [Event]. 45 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 46: Camera Control

    Images] user interface. If the cameras are logged as red, a blue screen is displayed. 12.3.1 Camera Control Click on Vout#1 control A pop up window appears Switch between multi and single channel. Select cameras. Figure 8) Camera control 46 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 47: Maintenance

    NOTICE The web browser must be set such that the access to BOP XD does not happen over a proxy. 12.4 Maintenance Error messages are shown in the [MAINTENANCE] page. All events that have led to a data recording failure are logged in the error file.
  • Page 48: Error File Structure

    Line 3 - date and time errors l NOTICE The error file err.txt can be read and deleted by all users. 12.4.3 Maintenance HDD Report Figure 10) HDD Report 48 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 49: Recording Test

    Figure 11) Activate HDD Figure 12) Recording check 12.4.4 Recording Test Using the [Recording test] button, the recording functionality of the latest terminated sequences is tested. Figure 13) Recording Test 49 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 50: Configuration

    12.5.1.1 Date and Time BOP xD contains a real-time clock [RTC]. In case of deviations, the [RTC] should be adjusted because otherwise the time stamps of the data recordings do not allow for conclusions regarding the exact recording time. The time zones can be changed. The [save] button saves the PC time in the BOP Real Time Clock [RTC].
  • Page 51: Language

    BOP is installed must be entered. The vehicle identification is displayed when reading the data in BOP ReviewerSoftware.  Vehicle identification - BOP serial number, bus licence plate number 51 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 52: Sequencing Time

    The video surveillance system is not switched-off together with the ignition, but after a predefined switch-off delay time. If the ignition is switched on again within this period of time, BOP is not switched off and the switch-off delay is reset. 52 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 53: Pre-Alarm And Post-Alarm Buffer

     Alarm Data Age - 14.90 to 365 days - older alarm data is pushed back in the alarm storage.  Flank alarm input - defines the trigger direction - 0 = up, 1 = down 53 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 54: Key Switch

    This can be classified and protocolled as an error.  0 = Error entry due to supply voltage failure  1 = No error entry due to supply voltage failure 54 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 55: Error Signalling Time

    You can configure an automatic restart. 12.5.1.16 Inputs  Pause input #4 - 0 = OFF, 1 = digital input, #4 stops the recording (customer sp ecific) 55 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 56: Camera Issue / Error

    Figure 18) IBIS 12.5.1.20 Temperature Management The hard drives are automatically shut down after exceeding or falling below the temperature limits. Recording is stopped. The temperature limits are configurable. 56 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 57: Audio Settings

    The video settings (codecs’ settings) affect all video sources. In the video recording settings configuration, the values of the different analogue camera can be set. Column 1-4. Figure 20) Video Settings 1 57 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 58: Resolution

    Higher data volumes determine shorter recording times on the storage device.  Low data rate Higher compression, therefore lower image quality. Smaller data volumes allow for longer recording times on the storage device. 58 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 59: Gop Time

    Higher chance of compression artefacts thus possibly a worse-quality image  1 Adaptive framerate on Lower chance of compression artefact but a jerkier image due to the lower number of images/sec. 59 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 60: Text Overlay

    Heavy fluctuations in the short run, but a constant data rate in the long run (optimal for data recording)  1 Streaming mode on Constant data rate in the short run due to the high compression (optimal for streaming). 60 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 61: Video Settings 2

    A camera is blind when it is covered or sprayed over. A brightness sensor can be connected to it which is activated under [General settings]. 61 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 62 Web Interface Figure 22) Camera Configuration 62 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 63: Ip-Cmas V-Out Configuration

    Please delete URL entries that are not used to reduce system load.  Connection – 0=BNC analogue, 1=HDMI  OSD label- 0= no label, 1= Camera No., 2= Camera Name 63 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 64: Outputs

    1 (and therefore to the connected monitor). reversing camera and a doors camera can be ass to Video output 1 with display priority. Figure 25) Video Output 1 Figure 26) Video Output 2 64 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 65: Automatic Restart

     V.. = video input / multiscreen selection  v1 .. v16 = single screen display of the specified video channel  v20 .. v23 = multiscreen display  t.. = display duration 65 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 66: Default Video Input

    A camera with display priority can be determined for surveillance of the area behind the vehicle.  0 = No reversing camera available  1 .. 8 = Video input of the reversing camera 66 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 67: Door Camera

    Messages or the system status can be transmitted to external units via the relays. Figure 28) Relays Default relay functionality: Relay 1: active relay. Closed when is started. It is only open when switched off. 67 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 68: Automatic Relay Control

    Alarm recording can be signalled via the “Recording active” Relay 2.  0 Relay “Recording a ctive” constantly toggled during data recording regardless of whether standard data or alarm data is being recorded. 68 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 69  1 Relay “Recording active” constantly toggled during data recording. Relay 2 flashes during alarm data recording. This behaviour can be used when there is only one signalling lamp available. 69 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 70: Network

     NOTICE all modifications that have been performed. Figure 29) Network paramters The communication parameters for the front and back Ethernet interface are set via the network parameters. 70 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 71: Ip Address / Netmask In Front

    IP address and Netmask for the Ethernet interface in the back. Per default, it is set after the 10.30.xx.yy schema, whereas xx represents the two second last and yy the last two numbers of the BOP xD serial number (SN:1030xxyy).
  • Page 72: Error File And Alarm Message Transfer

     Modify settings only following network administrator’s instructions.  NOTICE all modifications that have been performed. 72 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 73: Video Ftp Host / Port / User / Pass

    In the event of an alarm, all data is deposited in the alarm folder and it is labelled. After the data has been transferred, the alarm label is removed and data is transferred to the buffer storage. 73 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 74: Load/Save Configuration - Firmware Upload

    Figure 31) Firmware upload Pay attention to the order!! Begin by uploading the firmware first and the configuration second. NOTICE The new firmware is enabled only after a restart. 74 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 75: Saving The Current Configuration

    + restart] file name default configuration files looks something like vss3.0.25cfg_default_de.bcf  vss3.0.25 firmware for the configuration file  cfg stands for configuration  fault as in default configuration 75 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 76: Loading A Firmware

     do not switch -off BOP xD  do not cut the power supply NOTICE To back up the BOP xD settings, we recommend saving the current configu- ration before uploading the firmware. 76 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 77: Operator

    The operator can use a USB stick as authentication for downloading passenger count data. Figure 32) Alarm files 12.2.1 Test Mode Switch on the device Wait for a moment Flip the key switch to “OFF” 77 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 78: Downloading Passenger Count Data Per Usb Stick

    Select the batch files that also need to be generated for the read functionality. * Read log files - "vssLOGread" * Read passenger count data – „vssAPCdataread“ * Read and delete passenger count data – „vssAPCdatagrab“ Figure 33) USB identification 78 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 79: Admin

    Figure 34) Passwords  Normal user - “user”  Service technician “cfg”  Reviewer - “review”  Temporary ALARM access “live”  Administrator - “admin” 79 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 80 The following rules apply when creating a password  Minimum length - 3 symbols  Maximum length - 16 symbols  Valid symbols - capital and small letters, numbers 80 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 81: Data Storage Access

    Folder - camera* The folders “camer01” to “camera16” contain the video data of the respective video sources. For this purpose, the video data is distributed in packages and saved in 81 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 82: Formatting The Data Storage

    The analysis of the data on a Reviewer Station guarantees central evaluation of the data as well as independence from the BOP xD system used for surveillance. 82 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 83 In exceptional cases, data analysis can also be performed on site with a laptop with the Reviewer Software installed. For this purpose, BOP xD is switched to the >PAUSE< operation mode. 83 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 84: Error Description

    USB hub sends a com- Check the con- munication issue notifi- tact to the USB cation and the con- daemon.err klogd: nected devices hub.c: connect- debounce failed, port 1 84 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 85 In BOP, the alarm data can be brought back to the normal data circuit via the web menu Op- erator even without format- ting. Table 9) Error Description 85 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 86: Boot Specials Bop Xd

    If the key switch-off mode is set to “1” and the key switch is flipped to “off”, the power supply must be disconnected unless the slide disk will be changed. 86 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 87: Complete System Maintenance / Functionality Check

     If the red “LED Error” is flashing, the configuration menu should be open as described in Chapter 12, Web Interface.  The error files can be found there.  Take the necessary measures and, if necessary, contact ACTIA I+ME GmbH.  Delete the errors.
  • Page 88: Bb R Ev I At I On S

    IP40 MPEG /H264 Video coding format for the recording of Full HD video and audio data NTSC Television standard, National Television Systems Committee Television standard, Phase Alternating Line Process 88 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 89 Video surveillance systems for security purposes as per the EN 62676 standard Describes negative voltage, source voltage based on multiple tran- sistors xNet WLAN /UMTS /HSDPA Modem Table 10) Abbreviations 89 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 90: Pp E Nd Ix

    Camera cable lengths of 3/6/10/15/20/30 meters VDC connection AR10010878 USB connection adapter for connecting the adapter with hard disk to a USB 3.0 port on the PC power supply 90 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 91: List Of Figures

    Figure 22) Camera Configuration................. 62 Figure 23) Configuartion_IP –CAMS-V-Out ..............63 Figure 24) Configuration iShow ................... 64 Figure 25) Video Output 1 ..................64 Figure 26) Video Output 2 ..................64 91 / 92 © 2018 ACTIA I+ME GmbH │ Ref. IR:14938...
  • Page 92: List Of Tables

    Figure 34) Passwords....................79 16.3 List of Tables Table 1) Standards and guidelines ................10 Table 2 ) BOP xD Technical Details ................16 Table 3) Key Switch Positions ..................28 Table 4) Visual Indicators, Light Diodes................ 29 Table 5) Recording Capacity in Hours* ................. 32 Table 6) Recording Capacity in Hours* .................

Table of Contents