WARNING: NEVER USE THIS RESPIRATOR
IN AN AREA WHERE THE ATMOSPHERE IS
IMMEDIATELY HAZARDOUS TO LIFE OR
HEALTH. IN AN EMERGENCY THE WEARER
MUST BE ABLE TO ESCAPE FROM THE
WORK AREA WITHOUT THE NEED OF A
RESPIRATOR.
THE AIR SUPPLIED MUST BE OF
BREATHABLE QUALITY AND CONFORM TO
BSEN 12021:1999 AND THE RELEVANT
NATIONAL AND LOCAL STANDARDS.
ONLY USE RECOMMENDED DEVILBISS
SUPPLY HOSE
CAUTION: It is essential to site the air intake of
the compressor so that the air intake is free
from contaminants. The compressed air must
be regularly checked for breathable quality.
WARNING: DO NOT ENTER THE
CONTAMINATED AREA UNTIL ITEM (10) IS
COMPLETED
1) Connect the air supply hose to the outlet of a
coalescing air filter such as a DVFR 2. Do not
turn on the air supply.
NOTE: Ensure that the supply hose is of
sufficient length to allow the operator to enter
and leave the contaminated area without
disconnecting or removing the vizor.
2) Check the waistbelt and respirator
assemblies ensuring that all parts are in good
condition. Replace if damaged.
3) Attach and adjust the waistbelt assembly
ensuring that the supply air inlet and spray gun
outlet connectors are pointing down.
4) Connect the air supply hose to the waistbelt
inlet.
5) Connect the respirator feed tube to the outlet
socket on top of the filter assembly.
6) Connect the spray gun air supply hose to QD
outlet on the bottom of the filter assembly (if
required).
© 2003 ITW Finishing Systems and Products
INSTALLATION / OPERATION
DONNING PRODEDURE
4
As a precaution against a supply failure or
pressure loss an audible low pressure warning
device should be fitted as described under
accessories.
NOTE:
It is recommended that a new air
supply hose item (18) fig1 is used and specially
identified for breathing air. In the interest of
hygiene each user should have their own face
mask and hood.
HOSE LENGTH: Note 10m is the maximum
hose length that can be used due to the
minimum pressure requirements.
If longer hose length is required a portable
coalescing air filter device must be located at
the supply end of the10m hose and be capable
of supply pressure of 3.8 Bar (55 lbf/in²) at this
.
point
7) Place the vizor assembly on the head and,
with the vizor in the open position, adjust the
tension knobs.
Ensure that the feed tube is not twisted or
kinked and will not interfere with normal
movements.
8) Turn on the air supply and check that the air
is flowing freely to the inside of the vizor.
9) Adjust the air pressure with the gun (if fitted)
triggered to ensure that the minimum supply
pressure at the inlet of supply hose is in
accordance with the minimum requirements 3.8
bar (55 psi).
10) Before entering the contaminated area, the
vizor must be pulled down, so that the foam
face seal is located under the chin and in
contact around its entire periphery, the tension
knobs are adjusted so that the vizor is locked in
this position.
NOTE: Do not lift or remove the vizor inside the
contaminated area. Retreat from the area
immediately if any malfunction is suspected or if
the warning whistle sounds (if accessory fitted).