B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION AND EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws (bearing setscrews), non-permanent gas connections (unions, shutoff valves, orifices, and
grounding connections). Motor and drive belts should be examined. Cracked or seriously frayed belts should be
replaced. Tighten loose V-belts when necessary. Complete operational check of controls and valves. Complete
operational check of ALL safety devices (door switch, lint drawer switch, sail switch, burner and hi-limit thermostats).
30 DAYS AFTER INSTALLATION
SHUT OFF ALL POWER TO THE DRYER. Verify that the electrical connections to the motor contactors and
overloads are tight. This is done to accommodate the compression of the wires over time.
C. LUBRICATION
MONTHLY
The two (2) 1-3/8" (3.5 cm) bearings that support the impellor/fan shaft should be lubricated. Use Shell Alvania #2
grease or its equivalent. Impellor/fan shaft bearings must be lubricated.
EVERY 3 MONTHS
The four (4) 1-1/2" (3.81 cm) bearings that support the drive and idler shaft should be lubricated. Use Shell Alvania
#2 grease or its equivalent. Drive and idler shaft bearings must be lubricated. The motor bearings, idler bearings ...
and under normal/most conditions the tumbler bearing are required to be lubricated.
EVERY 6 MONTHS
Remove the gear oil in the tumbler drive shaft gear reducer. Replace with 1.4 liters of Mobil oil DTE HH5G (I.S.O.
viscosity grade 460) or its equivalent.