Honeywell Fault Codes; Honeywell Burner Control Faults (Blink Codes); Honeywell Keyboard Display Module Sequence And Status Hold Messages - Brock MEYER ENERGY MISER ME1000S Schematics

Tower dryer
Hide thumbs Also See for MEYER ENERGY MISER ME1000S:
Table of Contents

Advertisement

Honeywell Fault Codes

Honeywell Fault Codes
Blink Code*
1-1
1-2
2-1
2-2
2-3
3-1
3-2
3-3
4-1
4-2
* Blink Codes are read from the green power LED when the relay module is locked out
(alarm LED is on). A blink code consists of 1 or more fast blinks followed by one (1) or more
slow blinks.

HONEYWELL Keyboard Display Module Sequence and Status Hold Messages

18

Honeywell Burner Control Faults (Blink Codes)

Fault Description
Low AC Line Voltage
AC Quality Problem
Unexpected Flame Signal
Flame Signal Absent
Flame Signal Overrange
Running ILK Switch Problem
Running ILK Switch in Standby
Valve Proving Fault
Purge Card Problem
Wiring Problem/Internal Fault
BROCK® MEYER® Schematics
Blink Code*
Fault Description
4-3
Flame Amplifier Problem
4-4
Configuration Jumper Problem
5-1
PII Fault
5-2
HFS/LFS Fault
5-3
MOS/Start Switch
6-1
Output Drive Failure
6-2
Internal Fault
6-3
Device Specific Fault
6-4
Accessory Fault
7-7
Unrecognized Fault
MFH1968-3G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MEYER ENERGY MISER ME1000S and is the answer not in the manual?

Questions and answers

Table of Contents