AC charging socket
The AC charging socket is located below the RFID reader. The cover prevents the ingress of
dust and moisture. The integrated shutter represents an additional mechanical protective
measure for personal safety and is intended to ensure that the power contacts cannot be
touched by fingers or objects.
Figure 3-2
The charging socket is also equipped with an actuator which locks the charging cable before
the charging process is started, and only releases it again when the charging process is
complete. The charging cable with Type 2 plug must be provided by the user and it must
support Mode 3.
The following table illustrates the pin assignment of the socket.
Table 3- 4
No.
DC meter (optional)
The window with the display of the DC meters of the respective charging outlet on which the
released energy can be read is located below the plug holder. Please refer to the operating
instructions on the use of the device for more information on the contents displayed. Take
the exact device type from the parts list of your charging station.
SICHARGE D
Operating Instructions, 02/2021, 8EM5907-0AA00-1AA7.01
AC charging socket with protective cap and integrated shutter
Pin assignment of the AC charging socket
Contact
Proximity Pilot (PP)
Control Pilot (CP)
L1
N
L2
L3
PE
3.3 Display elements and operator controls
Use
Detects presence of the plug
Communication signal between vehicle and charging station
Line conductor L1
Neutral conductor
Line conductor L2
Line conductor L3
Protective conductor
Description