Quick Reference Guide
SIMPLEX 4010ES Optional Modules
Available Mounting Space: A "Block" is a single 4X5" card mounting area on the PDI.
Block
Main Board
A
Block
Block
B
D
Block
Block
Block
A
C
E
Block
Block
Block
B
D
F
1-Bay Box, can t one of the
following con gurations:
3 Individual Blocks
One Block and One Vertical Block Pair
One Block and One Horizontal Block Pair
Option cards use either a single block, a block pair, or three block spaces (refer to the chart below for individual option card requirements).
PID
Description
4010-9901
Flat Vesda HLI
4 Point Flat Aux
4010-9908
Relay Module
City Connect Module w/
4010-9909
disconnect switches
4010-9910
City Connect Module
4010-9911
Alarm Relay Module
4010-9912
Serial DACT
Building Network
4010-9914
Interface Card
4010-9915
BacPac Ethernet Module
4010-9916
25V Regulator Module
4010-9918
Dual RS232 Module
Block
TrueInsight Remote Service
4190-6105
G
Gateway Assembly for 4010ES
8 Zone Initiating Device
4010-9920
Circuit - Class B
8 Zone Initiating Device
4010-9921
Circuit - Class A
Block
4010-9922
Flat Network Card
H
4010-9923
SafeLinc
Modem Physical Bridge
4010-9924
Style 4
Modem Physical Bridge
4010-9925
Style 7
TCP/IP Physical Bridge
4010-9926
Style 4
TCP/IP Physical Bridge
4010-9927
Style 7
4010-9928
Double Card Mounting Kit
Network Card Media
4010-9818
Module - Wired
Network Card Media
4010-9819
Module - Fiber
4010-9929
IDNet 2+2
4010-9930
Dual Class A Isolator (DCAI)
2-Bay Box Available Mounting Space can t same as
1-Bay Box plus a combination of the following:
A
B
D
Top Bay (Single Bay)
Panel Mounted Optional Modules
Feature Limit
Other Restrictions
Blocks
1-Bay
2-Bay
1
1
The Vesda Interface consumes 1 Computer Port.
3
11
None
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Must mount in Top Bay, Block D (special bracket included). *If a second
2
2
DACT is used, it will consume 2 vertical blocks. Consumes 1 Computer Port.
1
1
None
1
5
Must be ordered with a 4010-9918 RS232 Module.
1
1
None
3
3
Limit of 5 RS232 Ports per system.
1
1
Connects to serial port of CPU card
None
1
1
Mounts in top Bay Blocks A and B only
1
1
Mounts in top Bay Blocks A and B only.
1
1
None
1
1
Consumes 1 computer Port.
1
4
Panel must contain a 4010-9922 network card.
1
4
Panel must contain a 4010-9922 network card.
0
2
Panel must contain a 4010-9922 network card.
0
2
Panel must contain a 4010-9922 network card.
Mounts in Single Bay Panel Blocks A&B only (requires 0650-473 Rev E or later bay pan).
1
0
Compatible cards (2 max): 4010-9913, -9914, -9922,-9923, -9924, -9925, -9926, -9927
None
2
2
2 Max per network card.
None
2
2
2 Max per network card.
3
3
None
4
4
2 per IDNAC channel
A
8 Individual Blocks (A through H)
B
4 Vertical Block Pairs (e.g. AB, CD, EF, GH)
4 Horizontal Block Pairs (e.g. AC, EG, BD, FH)
Expansion Bay
2 Vertical and 2 Horizontal Block pairs (e.g. AB, CD, EG, FH)
Connects to CPU Card Ethernet Port
Each BacPAC consumes 1 Computer Port.
Must use port B on RS232 Card.
Required for some devices used on 4010-9917 MX Loop Card.
Mounts to front door next to CPU Card.
Comes with 8V converter Module.
Both Mount in the same 2 vertical block space.
Comes with 8V converter Module.
Both Mount in the same 2 vertical block space.
1-Bay Panel requires 4010-9928 Mounting Kit.
Ships with 2 Wired Media modules and 1 Modem Media Module.
1-Bay Panel requires 4010-9928 Mounting Kit.
Ships with 2 Wired Media modules and 2 Modem Media Module.
Ships with 2 Wired Media modules and 1 TCP/IP Media Module.
Ships with 2 Wired Media modules and 2 TCP/IP Media Module.
Gives the ability to mount two Vertical 2 block cards. 4010-9926,
and 4010-9927 will also consume block D. In this con guration, the bridge
card should be right justi ed in the double card mount. Uses both the spare
4 pin PDI connector and the 6- pin PDI connector (bay to bay connector)
Order as required for 4010-9922
Order as required for 4010-9922
Limit of 3 assumes you have an MSS, MSS2 w/IDNet,limit is 4 otherwise.
One may be mounted on the ESS
C
E
G
D
F
H
Notes
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 4010ES and is the answer not in the manual?

Questions and answers

Summary of Contents for Simplex 4010ES

  • Page 1 SIMPLEX 4010ES Fire Alarm Panel 1-Bay Box, can t one of the 2-Bay Box Available Mounting Space can t same as following con gurations: 1-Bay Box plus a combination of the following: Quick Reference Guide 3 Individual Blocks 8 Individual Blocks (A through H) One Block and One Vertical Block Pair 4 Vertical Block Pairs (e.g.
  • Page 2 SIMPLEX 4010ES with ESS Main Board Descrip�on Terminal Block Provides 2 fault isolated loops of IDNet +. TB1 IDNet Connec�ons TB1 (1-4) Loop A, TB1 (5-8) Loop B Each IDNAC circuit has a 4 posi�on terminal block. TB2 IDNAC Connec�ons TB2 (1-4) IDNAC 1,TB2 (5-8) IDNAC 2 Provides 2 posi�ons for wiring the aux power...
  • Page 3 XBC. LED 12 NAC 1 NAC 1 TRBL OR NAC 1 “ON” Note: The 4010ES ba�ery size is 33 Ah in the one-bay box and 50 Ah in the two-bay box. LED 13 AUXNAC AUXNAC TRBL OR AUXNAC “ON”...
  • Page 4 XBC. LED 10 NAC 2 NAC 1 TRBL OR NAC 2 “ON” Note: The 4010ES ba�ery size is 33 Ah in the one-bay box and LED 11 NAC 3 NAC 1 TRBL OR NAC 3 “ON”...
  • Page 5 Ethernet Service Port – RJ45 connector used to transfer files to or upload reports from the the Ethernet connector and the Ethernet port is not available. 4010ES IDNAC using the Ethernet port on your laptop. a unique Serial Number. International Trade Controls and Restrictions This material may contain information or technology the export or re-export of which is restricted by U.S.