SIMPLEX 4010ES Fire Alarm Panel
Quick Reference Guide
SIMPLEX 4010ES Optional Modules
Available Mounting Space: A "Block" is a single 4X5" card mounting area on the PDI.
Block
Main Board
A
Block
Block
B
D
Block
Block
Block
A
C
E
Block
Block
Block
B
D
F
1-Bay Box, can t one of the
following con gurations:
3 Individual Blocks
One Block and One Vertical Block Pair
One Block and One Horizontal Block Pair
Option cards use either a single block, a block pair, or three block spaces (refer to the chart below for individual option card requirements).
PID
Description
4010-9901
Flat Vesda HLI
4 Point Flat Aux
4010-9908
Relay Module
City Connect Module w/
4010-9909
disconnect switches
4010-9910
City Connect Module
4010-9911
Alarm Relay Module
4010-9912
Serial DACT
Building Network
4010-9914
Interface Card
4010-9915
BacPac Ethernet Module
4010-9916
25V Regulator Module
4010-9918
Dual RS232 Module
Block
TrueInsight Remote Service
4190-6105
G
Gateway Assembly for 4010ES
8 Zone Initiating Device
4010-9920
Circuit - Class B
8 Zone Initiating Device
4010-9921
Circuit - Class A
Block
4010-9922
Flat Network Card
H
4010-9923
SafeLinc
Modem Physical Bridge
4010-9924
Style 4
Modem Physical Bridge
4010-9925
Style 7
TCP/IP Physical Bridge
4010-9926
Style 4
TCP/IP Physical Bridge
4010-9927
Style 7
4010-9928
Double Card Mounting Kit
Network Card Media
4010-9818
Module - Wired
Network Card Media
4010-9819
Module - Fiber
4010-9929
IDNet 2+2
4010-9930
Dual Class A Isolator (DCAI)
2-Bay Box Available Mounting Space can t same as
1-Bay Box plus a combination of the following:
A
B
D
Top Bay (Single Bay)
Panel Mounted Optional Modules
Feature Limit
Other Restrictions
Blocks
1-Bay
2-Bay
1
1
The Vesda Interface consumes 1 Computer Port.
3
11
None
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Mounts on MSS, MSS2 or back of heat sink bracket in ESS units.
None
1
1
Mutually exclusive with 4010-9910 and 4010-9911.
Must mount in Top Bay, Block D (special bracket included). *If a second
2
2
DACT is used, it will consume 2 vertical blocks. Consumes 1 Computer Port.
1
1
None
1
5
Must be ordered with a 4010-9918 RS232 Module.
1
1
None
3
3
Limit of 5 RS232 Ports per system.
1
1
Connects to serial port of CPU card
None
1
1
Mounts in top Bay Blocks A and B only
1
1
Mounts in top Bay Blocks A and B only.
1
1
None
1
1
Consumes 1 computer Port.
1
4
Panel must contain a 4010-9922 network card.
1
4
Panel must contain a 4010-9922 network card.
0
2
Panel must contain a 4010-9922 network card.
0
2
Panel must contain a 4010-9922 network card.
Mounts in Single Bay Panel Blocks A&B only (requires 0650-473 Rev E or later bay pan).
1
0
Compatible cards (2 max): 4010-9913, -9914, -9922,-9923, -9924, -9925, -9926, -9927
None
2
2
2 Max per network card.
None
2
2
2 Max per network card.
3
3
None
4
4
2 per IDNAC channel
A
8 Individual Blocks (A through H)
B
4 Vertical Block Pairs (e.g. AB, CD, EF, GH)
4 Horizontal Block Pairs (e.g. AC, EG, BD, FH)
Expansion Bay
2 Vertical and 2 Horizontal Block pairs (e.g. AB, CD, EG, FH)
Connects to CPU Card Ethernet Port
Each BacPAC consumes 1 Computer Port.
Must use port B on RS232 Card.
Required for some devices used on 4010-9917 MX Loop Card.
Mounts to front door next to CPU Card.
Comes with 8V converter Module.
Both Mount in the same 2 vertical block space.
Comes with 8V converter Module.
Both Mount in the same 2 vertical block space.
1-Bay Panel requires 4010-9928 Mounting Kit.
Ships with 2 Wired Media modules and 1 Modem Media Module.
1-Bay Panel requires 4010-9928 Mounting Kit.
Ships with 2 Wired Media modules and 2 Modem Media Module.
Ships with 2 Wired Media modules and 1 TCP/IP Media Module.
Ships with 2 Wired Media modules and 2 TCP/IP Media Module.
Gives the ability to mount two Vertical 2 block cards. 4010-9926,
and 4010-9927 will also consume block D. In this con guration, the bridge
card should be right justi ed in the double card mount. Uses both the spare
4 pin PDI connector and the 6- pin PDI connector (bay to bay connector)
Order as required for 4010-9922
Order as required for 4010-9922
Limit of 3 assumes you have an MSS, MSS2 w/IDNet,limit is 4 otherwise.
One may be mounted on the ESS
C
E
G
D
F
H
Notes
1
Need help?
Do you have a question about the 4010ES and is the answer not in the manual?
Questions and answers