Remote Controller - Haier YR-E06 Operation Manual

Haier yr-e06: user manual
Hide thumbs Also See for YR-E06:

Advertisement

Parts and Functions

Remote controller

28
27
29
26
30
25
31
B
A
24
32
23
33
22
34
A
U
T
21
O
35
OFF
M
D
20
36
19
1
TEMP
ON
2
18
OFF
SWING
FAN
3
MODE
SLEEP
4
17
HEALTH
FRESH
5
16
CLOCK
SET
6
15
TIMER
HIGH/SO
7
14
FILTER
HEAT
13
8
37
LIGHT
LOCK
RESET
CODE
12
9
11
10
1.TEMP Setting Button
(Used to set temperature. Setting ranges:
16 C to 30 C)
2.SWING Button
If you press this button once, auto swing will be
activated.
If you press this button again, the louver will fix
in the present position.
3.Power ON/OFF Button
Used for unit start and stop
After power on, the LCD of remote controller will
display the previous operation state (except for
TIMER,SLEEP and SWING state).
4.Operation MODE
Used to select operation mode.
NOTE: 1.Single cooling air conditioner does not have the displays and functions related to heating.
2.Some functions of this controller maybe not available according to the corresponding PCB's functions,such
as: In function of code A
2
5
8
11
14
16
17 21 24
3.HIGH/SO button:This button is active in Cooling/Heating mode, the fan speed is in AUTO mode after pressing
it and " high functon/soft function " will be automatically cancelled after 15 minutes running.
4.
HEAT button: This button can only be used for units with electric heater function.
Every time you press MODE button, operation mode
changes according to following sequence:
The function of code A
AUTO
DRY
HEAT
FAN
COOL
The function of code B
DRY
HEAT
COOL
5.HEALTH Button
6.CLOCK Button
Used to set correct time.
7.TIMER Button
The function of code A
Used to select TIMER mode:TIMER
ON,TIMER OFF, TIMER ON/OFF.
The function of code B
Used to select TIMER mode:TIMER
ON,TIMER OFF.
(Note: if time of TIMER ON is the same as TIMER OFF,TIMER
ON/OFF cannot be set)
8. FILTER Button
Used to set up/down function of filter.
9.CODE Button
Series
Used to select Code A or B,
wired remote controller
Series
units use Code A,
remote controller units use code B.
10.RESET Button
Press this button by using a sharp article to resume the
correct operation of the remote controller in case of need,
i.e. for example in case of malfunctions due to
electromagnetic disturbance.
11.LIGHT Button
Used to light the control panel (only for cabinet unit)
12.LOCK Button
Used to lock operation button and LCD display contents: by
pressing this button, other buttons comes out of function and
lock state display appears; if you press it again, lock state
will be no more active and lock state display will disappear.
13.HOUR Adjustment
Used to set clock and timer setting
14.HIGH/SO Button
Used to select HIGH or SOFT operation.
15.SET Button
Used to confirm TIMER and CLOCK settings when
heating or cooling.
which are optional for different unit.
28
29
30 33
3
Operation
The function of code A:Sleep function
Note: Before using this function of code A, must
adjust the clock, or the sleep function will be disordered.
Comfortable Sleep
At night, before going to bed you can press
down the SLEEP button on the controller
and the air-conditioner will run by the
comfortable sleeping mode to make you sleep
more comfortable.
In cooling, dehumidifying mode
One hour after sleeping operation start, the temp. is 1 higher than the setting one. After another hour the
temp. rises 1 and then run continuously for another 6hrs' and then close. The actual temp. is higher than
the setting one which is to prevent from being too cool to your sleep.
In heating mode
One hour after start up, the temp. decrease 2 lower than the setting one. After another hour decrease by
more 2 .
The temperature will automatically rise by 1 after another 3hrs' operation, and then automatically close
after 3hrs' continuous operation. The actral temperature is lower than the setting one which is to prevent
from being too hot to your sleep.
Note: In AUTO mode, unit will run in SLEEP function according to the operation mode.
After setting SLEEP function, it is forbidden to calibrate clock.
If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time
is complete.
Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER-ON
function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first,
the TIMER function can not be set.
After setting sleep function, not allowed to adjust the clock. Can't use the remote controller operate the
AC. If so, please cancel the sleep function first.
After setting sleep function, can't set the timing function.
SETTING T
SHUT DOWN
1 hr
decrease 2
1 hr
decreases 2
about 3 hrs
increase1
3 hrs
SLEEP RUN BEGINS
SLEEP RUN STOPS
Heat mode
A
U
SWING
T
MODE
FAN
O
OFF
TEMP
HEALTH
TEMP
CLOCK
SET
ON
SET
TIMER
SLEEP
OFF
SWING
OFF
HEAT
FILTER RESET
MODE
RESET
AM
AM
HEALTH
FRESH
ON/OFF
CLOCK
TIMER
FILTER
LIGHT
RESET
CODE
SLEEP RUN BEGINS
SLEEP RUN STOPS
about 6 hrs
increase 1
1 hr
increase 1
1 hr
SHUT DOWN
SETTING T
Cooling mode
8
A
FAN
SLEEP
SET
HIGH/SO
HEAT
LOCK