Download Print this page
Sealey AK424DX Instructions

Sealey AK424DX Instructions

24ltr mobile oil drainer with air discharge & probes

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.
SAFETY INSTRUCTIONS
1.1.
GENERAL SAFETY
WARNING! Ensure that Health & Safety, local authority and general workshop practice regulations are adhered to
F
when using this equipment.
Familiarise yourself with the applications, limitations and hazards of the oil drainer.
!
WARNING! Disconnect the drainer from the air supply before changing accessories, servicing or performing any maintenance.
F
Maintain the drainer in good condition (use an authorised service agent).
!
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate
!
the warranty.
Keep the work area clean, uncluttered and ensure that there is adequate lighting.
!
Keep the drainer clean for best and safest performance.
!
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
!
Keep children and unauthorised persons away from the work area.
!
WARNING! Ensure that the correct air pressure is maintained and not exceeded.
F
Keep air hoses away from heat, oil and sharp edges. Check air hoses for wear before each use, and ensure that all
!
connections are secure.
DO NOT use the drainer for any purpose other than that for which it is designed.
%
DO NOT operate the drainer if any parts are damaged or missing as this may cause failure and/or personal injury.
%
DO NOT stand on the drainer.
%
DO NOT adjust or tamper with the safety valve.
%
DO NOT move the drainer by the hose, or yank the hose from the air supply.
%
DO NOT place attachments close to your face (especially eyes, ears etc.) and do not point air hoses at other
%
persons or animals.
DO NOT allow untrained persons to operate the drainer.
%
DO NOT operate the drainer when you are tired or under the influence of alcohol, drugs or intoxicating medication.
%
DO NOT leave the drainer operating unattended.
%
When not in use disconnect from the air supply, vent reservoir and store in a safe, dry, childproof area.
!
Dispose of waste oil in accordance with local authority regulations.
!
WARNING! DO NOT pollute the environment by allowing the uncontrolled discharge of waste oil.
F
2.
INTRODUCTION & ASSEMBLY
2.1.
Introduction
2.1.1. The AK424DX has a steel fabricated 24ltr reservoir, a telescopic steel drain pan and a metal filter grid. A venturi suction pump powers
the oil dipstick probes. Included is a set of three quick release, 675mm long probes - 5, 6 and 8mm diameter. Gravity or suction feed
oil drainer with air discharge. Fitted with an oil level indicator.
2.2.
Assembly
Note: Numbers in brackets refer to item numbers on the Parts Diagram.
2.2.1. Screw the oil drain pan (79) onto the support pipe valve (77), using connector (19).
3.
AIR SUPPLY
The recommended hook-up is shown in fig. 1.
3.1.
Ensure the air valve is in the "Off" position before connecting to the air supply.
3.2.
You will require an air pressure of 8 - 9 bar.
F
WARNING! Ensure the air supply is clean and does not exceed pressure
specified in these Instructions. Too high an air pressure and/or unclean air will
shorten the drainer life due to excessive wear, and may be dangerous, causing
damage and/or personal injury.
3.3.
Drain the compressor air tank daily. Water in the air line may damage the drainer.
3.4.
Clean the air inlet filter screen weekly.
3.5.
Line pressure should be increased to compensate for unusually long air hoses
(over 8 metres). The minimum hose diameter should be 10mm I.D. and fittings
must have the same inside dimensions.
3.6.
Keep hose away from heat, oil and sharp edges. Check hoses for wear and make certain that all connections are secure.
INSTRUCTIONS FOR:
24LTR MOBILE OIL DRAINER WITH
AIR DISCHARGE & PROBES
AK424DX
Model:
fig. 1
AK424DX - 1 - 120803

Advertisement

loading

Summary of Contents for Sealey AK424DX

  • Page 1 Introduction 2.1.1. The AK424DX has a steel fabricated 24ltr reservoir, a telescopic steel drain pan and a metal filter grid. A venturi suction pump powers the oil dipstick probes. Included is a set of three quick release, 675mm long probes - 5, 6 and 8mm diameter. Gravity or suction feed oil drainer with air discharge.
  • Page 2 97/23/EC Pressure Equipment Directive 93/68/EEC CE Marking Directive For Jack Sealey Ltd. Sole UK importer of Sealey Power Products. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.