Do not use the measuring tool in explosive atmospheres which contain flam-
u
mable liquids, gases or dust. Sparks may be produced inside the measuring tool,
which can ignite dust or fumes.
The measuring tool may not be 100% accurate for technological reasons. Envir-
u
onmental factors (e.g. dust or steam in the area being measured), temperature fluctu-
ations (e.g. from fan heater) as well as the nature and condition of the surfaces being
measured (e.g. highly reflective or transparent materials) can distort measurement
readings.
Product Description and Specifications
Please observe the illustrations at the beginning of this operating manual.
Intended Use
The measuring tool is intended for contactless measurement of surface temperature, am-
bient temperature and relative humidity. It calculates the dew point temperature and in-
dicates thermal bridges and mould risk. Mould spores cannot be detected with the meas-
uring tool.
The measuring tool must not be used for temperature measurement on persons and an-
imals or for other medical purposes.
The measuring tool is not suitable for surface temperature measurement of gases or li-
quids.
The measuring tool is not intended for commercial use.
The measuring tool is suitable for indoor use.
Product features
The numbering of the product features shown refers to the illustration of the measuring
tool on the graphic page.
(1) Measure button
(2) Laser beam outlet aperture
(3) Infrared beam reception lens
(4) Humidity and temperature sensor
(5) Emissivity label
(6) Laser warning label
(7) Serial number
(8) Retaining strap holder