Model GF-3200PFT
Installation Manual
Please Read And Save These Instructions
1.
Your new humidifier carries a 5-year limited warranty.
2.
For our complete warranty policy visit www.generalaireiaq.ca.
GF-3200PFT
CAUTION!
!
This symbol and the word "CAUTION" indicates:
IMPORTANT INSTRUCTIONS!
Failure to heed
Inside The Box
• DP-DS00200 Vapor Pad
®
With Frame
• Pulse Solenoid
• Integral Bypass Damper With Duct Collar
• Manual Humidistat
• 24V Transformer
• Hardware Kits
• 1/4" Diameter plastic supply tubing for hot or cold water applications
• 6" Diameter rigid and flexible by-pass duct
• Electrical wire
• 1/2 x 1/2 x 1/4 CSA approved ball valve
HSA055 Pulse
Electronic Controller
• Drain Hose
WARNING:
Do not install where ambient temperatures fall below 32°F / 0° C or where plenum temperatures exceed 200° F / 93° C.
!
For maximum evaporative capacity, install this humidifier on the warm air supply plenum.
Canadian General Filters
Limited
!
!
CAUTION! or
WARNING! can result in serious injury or death.
Canadian General Filters, Ltd.
400 Midwest Road
Toronto, ON M1P3A9
Toll Free: (888) 216-9184
www.generalaireiaq.ca
Evaporative Humidifiers
Plenum Installation Location:
humidifiers may be installed on either the return or supply
plenum of a forced air handling system. The humidifier's bypass
panel is reversible and can be mounted on the right or left side
of the humidifier. Select a location for the humidifier that allows
for service and maintenance.
Supply
Return
Vertical
Installation
Options
Drain Line
WARNING!
!
This symbol and the word "WARNING" indicates:
IMPORTANT INSTRUCTIONS!
• WARNING:
DISCONNECT ELECTRICAL POWER
!
BEFORE BEGINNING INSTALLATION.
!
IMPORTANT:
To ensure your safety and the
longevity of your unit, we recommend:
Contacting a licensed contractor to perform
maintenance or repairs.
Changing your Vapor Pad
heating season.
Model GF-3200PFT
Return
Supply
Horizontal Installation
Drain Line
at the start of each
®
®

Advertisement

loading
Need help?

Need help?

Do you have a question about the GF-3200PFT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GeneralAire GF-3200PFT

  • Page 1 Model GF-3200PFT Evaporative Humidifiers Installation Manual Please Read And Save These Instructions Plenum Installation Location: Model GF-3200PFT Your new humidifier carries a 5-year limited warranty. humidifiers may be installed on either the return or supply For our complete warranty policy visit www.generalaireiaq.ca.
  • Page 2 INSTALLATION PREPARING THE UNIT Install and fasten the water diffuser, the long plastic piece, with two screws (#6 x 1/2") inside the top part of the humidifier. Install the solenoid valve (mounted on a plastic bracket) outside of the top of the humidifier.
  • Page 3 INSTALLATION INSTALLING THE VAPOR PAD The pad is enclosed in a plastic frame having molded markings that clearly indicate the bottom. Slide the pad into the bottom part of the humidifier, the little bump at the top facing you. Push the pad against the back opening of the humidifier and lock into place with the pad retainer.
  • Page 4 INSTALLATION INSTALLING THE 120 VOLT TRANSFORMER Note: Do not install it on a furnace supplied with a different voltage. Connect the transformer primary to the relay activated when the furnace is in a heating cycle. Some furnaces have power terminals that can be used for accessories.