Technical Data - Electrolux GPE363YK User Manual

Table of Contents

Advertisement

9. TECHNICAL DATA

9.1 Hob dimensions
Width
Depth
9.2 Bypass diameters
BURNER
Multi Crown
Semi-rapid
Auxiliary
9.3 Other technical data
TOTAL POW‐
ER:
Electric sup‐
ply:
Appliance cat‐
egory:
Gas connec‐
tion:
Appliance
class:
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER
Multi Crown
Semi-rapid
Auxiliary
9.5 Gas burners for NATURAL GAS G20 13 mbar
BURNER
Multi Crown
Semi-rapid
Gas original: G20 (2H) 20 mbar
Gas re‐
G30/G31 (3B/P) 30/30 mbar
placement:
G20 (2H) 13 mbar
220-240 V ~ 50-60 Hz
II2H3B/P
G 1/2"
3
NORMAL POWER
kW
3,9
2,0
1,0
NORMAL POWER
kW
3,9
2,0
590 mm
520 mm
Ø BYPASS 1/100 mm
57
35
28
MINIMUM POWER
kW
1,4
0,6
0,33
MINIMUM POWER
kW
1,4
0,6
ENGLISH
17
8,9 kW
607 g/h
8,9 kW
INJECTOR MARK
146
96x
70
INJECTOR MARK
166
112°