Page 1
If you prefer written instructions, please read ahead! With Rockville you get many options. rockvillesupport.com/rf-wedge-black rockvillesupport.com/rf-wedge-white Missing items? If you ordered a bundle that includes more than one product and you are missing part of your bundle then it just means your order shipped from two different warehouses.
Page 2
Thank you for purchasing this Rockville RF WEDGE. Please read this installation guide carefully for proper use of your RF WEDGE. Should you need assistance, please call our technical help line at 1-646-758-0144, 24 hours a day/7 days a week.
IMPORTANT SAFETY INSTRUCTIONS • To reduce risk of electric shock, never open the unit. There are no user serviceable parts; refer service to the Rockville service center. • Avoid looking directly into the lights. • Do not expose this unit to any kind of moisture.
Page 4
FUNCTIONS CHARGING MASTER SLAVE/DMX WIRELESS DMX CODE 1. Battery level LED indicators 2. LCD display shows unit status 3. Sound mode mic 4. Menu: Enter menu mode/cycle through menu options. Down: Scroll down through menu or scroll through selection. Up: Scroll up through menu or scroll through selection. Enter: Confirm selection.
Setting Wireless DMX Frequency Groups The RF WEDGE features seven individual 2.4GHz groups so you can organize your fixtures. Each group is represented by a color. First, set the Mode Switch to SLAVE/DMX, then use the wireless DMX frequency set button to select any one of the seven available group...
OPERATION Master/Slave Function In this mode you can connect multipe fixtures together and have one of the fixtures control all others without the use of a DMX controller. 1. Turn on all fixtures. 2. Connect all fixtures wirelessly or via the DMX IN/DMX OUT ports. If connecting wirelessly, make sure that all fixtures are set to the same wireless DMX frequency group.
Display Codes (continued) Display Value Description Mode B255 (B000 – B255) Manual dimming, BLUE U255 (U000 – U255) Manual dimming, WHITE Y255 (Y000 – Y255) Manual dimming, AMBER Manual dimming, UV P255 (P000 – P255) Set the unit to slave mode. SLAv Press the ENTER button, then use the UP or DOWN buttons to toggle between 6Ch and 10Ch.
Page 8
DMX Termination (Optional) The last fixture of a DMX chain has to be “terminated.” This prevents electrical noise from disturbing and corrupting the DMX control signals. To terminate the last fixture, solder a ¼ Watt, 120 Ohm resistor across the DATA - and DATA + wires. The connections are illustrated below.
Page 9
MOUNTING Please follow the directions below for safely hanging the RF WEDGE on a truss. You will need an adjustable wrench and pliers. Please use a safety cable when hanging the fixture. This will prevent any injuries in the event that the fixture falls.
FEATURES AND SPECIFICATIONS • RF remote with 70 foot range and Dual channels (RF remote can control many lights at the same time from a distance) • 3 mode switch (RF, Master, Slave/DMX) allows for the ultimate flexibility and control •...
• Unit Weight: 4.4 Lbs • Wireless DMX range: 1,000 to 1,500 feet Troubleshooting PROBLEM SOLUTION 1. Make sure the unit is plugged in and the black power switch is No power in the ON position. 2. Make sure the power cord is not damaged. 3.
Entrance A Inwood, NY 11096 Hereby declares that the product(s) Rockville RF WEDGE Wireless DMX Par Light complies with FCC rules as mentioned in the following paragraph: This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.