Hot-Plug Drive Led - HP MR Gen10 Plus User Manual

Table of Contents

Advertisement

Hot-plug drive LED

Hot-plug drive LED
Figure 2: LFF Low Profile (LP)
Figure 2: LFF Low Profile (LP)
Figure 3: SFF Basic Carrier (BC)
Figure 3: SFF Basic Carrier (BC)
Item
Item
LED
LED
Status
Status
1
1
Fault\Locate
Solid amber
Solid blue
Flashing amber/blue (1 flash
per second)
Flashing amber
(1 flash per second)
2
Online\Activity Solid green
Flashing green
(4 flashes per second)
Flashing green
(1 flash per second)
Definition
Definition
The drive has failed, unsupported, or invalid.
The drive is operating normally and being identified by a management
application.
The drive has failed, or a predictive failure alert has been received for this
drive; it also has been identified by a management application.
A predictive failure alert has been received for this drive. Replace the drive
as soon as possible.
The drive is online and has no activity.
The drive is operating normally and has activity.
The drive is doing one of the following:
Rebuilding
Performing a RAID migration
Performing a strip size migration
Performing a capacity expansion
Performing a logical drive extension
Erasing
Spare part activation
Hot-plug drive LED
59

Advertisement

Table of Contents
loading

Table of Contents