The formulas to calculate a maximum depend on various parameters such as:
label height, number of scans per second, code motion speed, etc. Minimum
label heights at different conveyor speeds are given in the tables in section ,
depending on standard a values of 45° and 30°.

Minimum Code Height for Advanced Code Reconstruction

Based on the scanner read rate of 1000 scans/sec., minimum label heights at
different conveyor speeds are given in the tables below.
Refer to the reading diagrams in
tures. These diagrams are taken on various resolution sample codes at a 25 C
ambient temperature depending on the conditions listed under each diagram.
ANSI Grade B minimum
1000 scans/sec
The following tables describe the requirements for standard applications.
Conveyor Speed (m/s)
2/5 Interleaved
Code Resolution
(mm)
Ratio 3:1
Reference Manual
Minimum Code Height for ACR Reading (mm)
45°
0.5
1
1.5
0.25
10
11
13
0.30
12
13
14
0.33
12
14
15
0.38
14
15
16
0.50
18
18
20
0.72
24
25
26
1.00
33
33
34
Advanced Code Reconstruction (ACR™)
section
for further details on the reading fea-
2
2.5
3
0.5
1
14
16
17
7
8
16
17
19
8
9
17
18
20
8
9
18
19
21
9
10
21
23
24
11
12
27
28
30
15
16
35
36
37
20
20
30°
1.5
2
2.5
3
9
10
12
13
10
11
12
14
10
12
13
14
11
12
14
15
13
14
15
17
16
18
19
20
21
22
23
24