Miele G 5892 Operating Instructions Manual page 71

Table of Contents

Advertisement

Reinstalling the spray arms
 Reinstall the upper spray arm and
tighten it by hand.
 Reinstall the middle spray arm.
 Reinstall the lower spray arm and en-
sure that the filter combination lies
flat in the base of the wash cabinet.
 Rotate the screw thread of the lower
spray arm clockwise until the arrow in
the viewing window points to the lock
symbol .
 Make sure the spray arms can rotate
freely.
Damage due to soiling entering
the circulation system.
The lower spray arm is used to se-
cure the filter combination. Without
filters, coarse soiling can enter the
circulation system and cause a
blockage.
Do not run a wash program without
the lower spray arm or without the fil-
ters.
Cleaning and care
Inserting the cutlery tray (if present)
 Slide the cutlery tray back onto the
rails from the front.
 Replace the safety clips in the rails on
both sides of the cutlery tray.
71

Advertisement

Table of Contents
loading

This manual is also suitable for:

G5000 seriesG5892scviG 5892 scvi sl