Function:
System can be through the U disk, program upgrade.
The specific operations are as follows:
1. Upgrade files
Copy the upgrade file STARTCNC.EXE to the usb drive.
2. Operation steps
After inserting the usb stick, press the pause button
Turn on the power and power on the system. After the upgrade interface appears on the system screen, release the
button.
The system will automatically perform the upgrade operation.
3. End of upgrade
If the program upgrade is successful, the system will prompt "upgrade successful!" And a buzzer will go off.
If the program fails to upgrade, the system will prompt "upgrade failed!" And the buzzer will ring continuously.
4. Start a new program
Turn off the power, pull out the U disk, and turn on the power again to start the new program. The version number of
the new program will be displayed on the screen after starting up.
Note:
If the upgrade is not successful, please check the following factors first:
1) the usb flash disk must be in FAT or FAT32 format. It is recommended to use FAT format.
2) the name of the upgrade file must be STARTCNC.EXE.
3) if during the upgrade process, there is no prompt to complete the process, but directly return to the main interface
of the upgrade, or the upgrade fails due to other accidents.
Can first check the upgrade file name is correct, U disk format is correct;
When excluding the upgrade file and U disk these two factors, you can follow the specific steps to upgrade again;
Appendix 1 software upgrade instructions
24
on the front panel of the system with your finger.