Fault Code Recovery
Fault Code Recovery
1.
To view the last 6 faults, press the "Menu" key until the "Last 6
Faults" (L6F) menu appears.
2.
Enter the menu by pressing the "Option" key.
3.
The last 6 faults can be viewed.
Clearing the Last 6 Faults
1.
To clear the last 6 faults, press the "Menu" key until the "Last 6
Faults" (L6F) menu appears.
2.
Enter the menu by pressing the "Option" key.
3.
Hold the "Option" key for at least 5 seconds.
4.
Release and a set of 3 dashes with be seen 3 times. This confirms
the faults have been cleared.
Resetting Factory Defaults
1.
Display must be in Idle Mode.
2.
Push the "Menu" and "Option" buttons at the same time for 15
seconds then release.
3.
The 7 segment will flash "FD" 3 times. This confirms the unit has
been reset to the factory defaults.
18-CE12D1-1D-EN
I I n n t t e e g g r r a a t t e e d d F F u u r r n n a a c c e e C C o o n n t t r r o o l l D D i i s s p p l l a a y y C C o o d d e e s s
S9X1 S9B1 IFC Component Layout
EAC, HUM
LINE
Dry Contacts
Connections
(S9X1 only)
Flame Current
FP
HLI
MV
GND
TH
MVC
HLO
PS1
TR
ILI
10 Pin
W R G B/C
Connector
Low Voltage Terminal Strip
5 Amp Fuse
Note: The S9B1 does not have EAC or HUM connections.
S9X2 IFC Component Layout
EAC, HUM
LINE
Dry Contacts
Connections
Flame Current
FP
HLI
MVH
MVL
GND
PS2
TH
MVC
HLO
PS1
TR
ILI
12 Pin
Connector
BK W2 W1 R G B/C Y2 Y1 O
5 Amp Fuse
Neutral
Inducer/Igniter
Connections
Connector
6 Pin CTM
Connector
IGN-N
IND-N
IND-H
IGN-H
7 Segment LED
MENU and OPTION
Select Buttons
6 Pin CTM Motor
Connector
Tap 1 - Low Speed
Tap 2
Tap 3
Tap 4
Tap 5 - High Speed
Y/Y1
Y2
Common
Neutral
Inducer/Igniter
Connections
Connector
6 Pin CTM
Connector
IGN-N
IND-N
IND-LO
IND-HI
IGN-H
7 Segment LED
6 Pin CTM Motor
Connector
Tap 1 - Low Speed
Tap 2
Tap 3
Tap 4
Tap 5 - High Speed
Common
MENU and OPTION
Select Buttons
Low Voltage Terminal Strip