WONDFO Finecare FIA Meter Plus Operation Manual
Hide thumbs Also See for Finecare FIA Meter Plus:

Advertisement

Finecare™ FIA Meter Plus (Model No.: FS-113)
TM
Finecare
FIA Meter Plus
Operation Manual
Model No.: FS-113
Version: 10/03/2016
Guangzhou Wondfo Biotech Co., Ltd.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Finecare FIA Meter Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for WONDFO Finecare FIA Meter Plus

  • Page 1 Finecare™ FIA Meter Plus (Model No.: FS-113) Finecare FIA Meter Plus Operation Manual Model No.: FS-113 Version: 10/03/2016 Guangzhou Wondfo Biotech Co., Ltd.
  • Page 2 Operation Instruction Ⅵ Instruction for connection with LIS system and PC Ⅶ Quality Control Ⅷ Warning, Precautions and Limitations Ⅸ Service, Maintenance and Disposal Ⅹ Trouble Shooting Ⅺ Contact Information Version: 10/03/2016 Guangzhou Wondfo Biotech Co., Ltd. - 1 -...
  • Page 3 WEEE (Waste Electrical and Electronic Equipment) Keep Dry Operation Temperature Limitation Storage and Transportation Temperature Limitation Keep away from Sunlight For in vitro Diagnostic Use only Manufacturing Date Serial Number Version: 10/03/2016 Guangzhou Wondfo Biotech Co., Ltd. - 2 -...
  • Page 4 Manufacturer Authorized Representative Direct current ON (Power) ○ Off (Power) - 3 -...
  • Page 5 For specific tests’ procedure please refer to the Instruction for Use of specific products. Finecare™ FIA Meter Plus manufactured by Guangzhou Wondfo Biotech Co., Ltd., is a portable instrument for fluorescence detection to quantify concentration of various kind of analytes in human blood or urine.
  • Page 6 Composition of System Unpacking After opening the package box, compare the contents with the list below. If any item is missing, please contact your sales distributor or Guangzhou Wondfo Biotech Co., Ltd. Ⅹ Ⅰ Detailed contact information is mentioned in Section Contents 1.
  • Page 7 Fig. 2.1 Structure Chart of Finecare™ FIA Meter Plus- Front View Printer Touch Screen Power and Communication interface Test Device Holder ID Chip Port Fig. 2.2 Finecare™ FIA Meter Plus Features - Left View Power switch, Ethernet Port, USB Interface, Serial Interface, Power interface, Selector switch for operating mode, which are used in Finecare™...
  • Page 8 Fig. 2.3 Power Adapter Consumables of Reagent Kit Fig. 2.4 Test Device Features (Remark: You shall buy the Test Devices separately) Note: This accessory is Test regent’s consumable Fig. 2.5 Test Device ID Chip (The ID Chip contains the information of test item and lot number) Note: This accessory is Test regent’s consumable Fig.
  • Page 9 Ⅲ Section Specifications and Operation Conditions Basic Specification Model No. FS-113 Excitation light source Center wavelength λ Excitation spectrum = 470nm Center wavelength λ Absorption spectrum = 525nm Test Specimen Whole blood, serum / plasma and urine Software system English and Chinese input method, customized intelligent management module Interface RS232, USB, Ethernet network...
  • Page 10 If you are uncertain of your power line, consult with your utility manager. The Finecare FIA Meter Plus can only be used with the power adapter (including the power cord) provided. If the replacement for Power Adaptor is required, please consult with your sales distributor or Guangzhou Wondfo Biotech Co., Ltd. 2. Installation Please be noted that Finecare™...
  • Page 11 V.1.4 Quick Test interface will be showed by default when you turn on Finecare™ FIA Meter Plus at the first time, after then boot screen displays the initial screen that the user once left off. (See Fig. 5.2) Fig 5.2 Quick Test interface Version: 10/03/2016 Guangzhou Wondfo Biotech Co., Ltd. - 10 -...
  • Page 12 If the initial interface doesn’t show after more than 3 minutes please turn off the Power ON/OFF Switch and restart the instrument. If failure continues, please contact your sales distributor or Guangzhou Wondfo Biotech Co., Ltd. V.2 Test Operation Example Please insert the ID chip of corrsponding test item before clicking “Test”, Under the initial interface of...
  • Page 13 *Caution: 1. It is recommended to insert ID chip after successful boot! 2. Please make sure the “selector switch for operating mode” on the left side of the instrument to be appropriated for "MAC”, when you choose the test mode of Finecare™ FIA Meter Plus’ system. 2.1 Choose Test mode ( Standard Test Quick Test...
  • Page 14 *Caution: If the lot number of the ID Chip does not match with the lot number of the Test Device when use the specific Test Device at the first time, the instrument will show “insert the corresponding ID chip”. Please check the lot number of ID Chip and Test Device if they are mismatched, please click " Change reagent and test again "...
  • Page 15 3.1 Click “History” on the top of the instrument to enter the query interface, the test results of intraday will be listed. (See Fig. 5.6) Fig. 5.6 3.2 Click “Query” under the “History” interface, then input the query conditions, Finecare™ FIA Meter Plus will filter out the test results that match the query conditions to conduct fuzzy query.
  • Page 16 3.4 Tick all or specific data record, click “Print” under the “History” interface to print a selected records. When the selected data is greater than 10, only 10 data can be printed. (See Fig. 5.9) Fig. 5.9 3.5 In the case of the LIS system was connected, select all or specific data record, click “LIS” under the “History”...
  • Page 17 V.4 Account Operation Example Click “Account” on the top of the instrument to enter the statistics interface. “Account” function provides the user with “Testing Account” and “Workload Account” function. Click “Testing Account” and “Workload Account” to show statistical results according to statistic conditions.
  • Page 18 V.5 Set Up Operation Example “Set Up” function provides the user with setting function for the machine function parameters, general users and R & D users, they can enter the appropriate there are two mode for users, including settings mode by using different password. Click “Set Up”...
  • Page 19 eneral user can only enter the "System Setting" interface to set LIS connection, bald temperature parameters. 5.2 R & D users interface, in addition to the "System Setting" function, also increase the "Parameter Setting" function. 5.2.1 ”Item Parameters” under the "Parameter Setting" , the users can add and interface modify test items and the reference range.
  • Page 20 5.2.3 Click “Edit” to modify the existing items’ parameters. 5.2.4 Click “Reset” to restore item parameters to the start parameter, then click ”OK” to complete the reset: 5.2.5 ”Device Parameters” under the "Parameter Setting" , the users can set “AD interface magnification times”, “Total length of the slot in running”, “Barcode recognition deadline”...
  • Page 21 “Sampling starting point”. AD magnification times: Magnification of fluorescence signal. Total length of the slot in running: The maximum distance of running forward when motor start with photoelectric switch. Barcode recognition deadline: The timeout period of barcode recognition. Sampling starting point: The starting position of fluorescence data collection. *Caution: Please note that this setting must be executed by authorized technical service personnel, unauthorized users shall not operate.
  • Page 22 Ⅵ Section Instruction for connection with LIS System and PC Ⅵ Connection with LIS system and PC This section introduce the operational instruction of Finecare FIA Meter Plus connect with LIS and Ⅵ Connection with LIS system and PC Transfer Protocol Instruction: FIA Meter Plus sends data to outside by UDP, click “LIS”...
  • Page 23 Fig. 6.2 3) Click “Properties” and enter to “Local Area Connection Properties”. (See Fig. 6.3) Fig. 6.3 4) Double click “Internet Protocol Version 4 (TCP/IPv4)”. Enter to “Internet Protocol (TCP/IP) Properties”. Set IP address as 192.168.0.88,click “OK” after finishing. (See Fig. 6.4) Fig.
  • Page 24 Method 2: Multiple Network Information Card Install one more NIC (Network Information Card) and corresponding driver in computer to work properly. Then use a standard network cable that can make normal PC access the Internet, one end of the network cable connects Finecare FIA Meter Plus’s Ethernet port, the other end connects PC 's Ethernet port of new Installed NIC.
  • Page 25 Router, Switchboard Ethernet Port Ethernet Port Network cable Ethernet Port Ethernet Port Network cable Click “Start” -> “Routine”-> “Attachment”-> “Communication”-> “Network”; double click “local connection” and enter to “Local Area Connection Status”, click “Properties” and enter to “Local Area Connection Properties”, double click “Internet Protocol Version 4 (TCP/IPv4)” and enter to “Internet Protocol Version 4 (TCP/IPv4) Properties”.
  • Page 26 2)Click “Add” under “IP address”, enter to“TCP/IP address”. (See Fig. 6.8) Fig. 6.8 3)Add IP address:192.168.0.88,Subnet mask:255.255.255.0 (See Fig. 6.9) Fig. 6.9 4)Then click “Add” to return to “Advanced TCP/IP settings” (See Fig. 6.10) Fig. 6.10 - 25 -...
  • Page 27 5)Click “Add” under “Default gateway”,enter to “TCP/IP Gateway Address”. (See Fig. 6.11) Fig. 6.11 6)Input Gateway:192.168.0.1, click “Add” after finishing, return to “Advanced TCP/IP settings”. (See Fig. 6.12) Fig. 6.12 - 26 -...
  • Page 28 7) Click “OK”, return to IP address setting menu, then click “OK” to exit IP setting, run the software of ReceiveFromCRPTemp.exe after setting successful. Note:Finecare FIA Meter Plus will send the current test results to computer automatically after test(in the case of LIS system is connected). Click “Record”, selected historical record can also be sent by clicking “Send”.
  • Page 29 "192.168.0.88" . 2) Choose “Ethernet configuration” to enter Network Settings interface. Click “Turn on Ethernet”, pop-up setting box where you can set the IP address of instrument terminal - 28 -...
  • Page 30 4) ) Set the network port IP address of instrument for LIS transmission and ensure consistency with IP address of the computer terminal. 5) Turn on LIS data receiving software of the computer, select "network port" and click “Start”. Note: LIS serial transmission function has been canceled, not verify here. 6) The instrument can test normally, the test results will be sent automatically to the PC reception software.
  • Page 31 7) Or check specific items and click “LIS” to upload the selected results to PC in the current result display interface. - 30 -...
  • Page 32 Ⅶ Section Quality Control When the Finecare FIA Meter Plus is used for the first time or each time, user can use the Quality Control Card to check the internal systems of the meter (including Optical System, Transmission System, Circuit System), to ensure instrument is functioning properly before testing through quality inspection of instrument.
  • Page 33 C lick “Reset the solt” if you do not need to use. Step 5 - 32 -...
  • Page 34 ● Do not subject Finecare™ FIA Meter Plus to mechanical shocks heavier than light taps with hands. ● Do not dismantle Finecare™ FIA Meter Plus without written authorization from Guangzhou Wondfo Biotech Co., Ltd. or its representative. ● Do not place heavy objects on Finecare™ FIA Meter Plus. This may damage the optical alignment to result in degraded performance or in mechanical damage.
  • Page 35 and systematic damage. ● Use only the Power Adapter (including the power cord) provided with Finecare™ FIA Meter Plus. ● Use Finecare™ FIA Meter Plus only in environment as specified in Section Ⅲ. ● Finecare™ FIA Meter Plus malfunction due to maintenance, processing or transporting damage, please contact customer service representative.
  • Page 36 FIA Meter Plus for replacing. The user is expected to utilize the packaging supplies accompanying the replacement to ship the malfunctioning unit in. Verify the return authorization number on the package and send the unit to Guangzhou Wondfo Biotech Co., Ltd. upon receiving the replacement Finecare FIA Meter Plus.
  • Page 37 Transporting and storing The original shipping container should be used to ship or transport Finecare FIA Meter Plus. The original shipping container is also recommended for storing Finecare FIA Meter Plus over an extended period. When transporting or storing Finecare FIA Meter Plus, keep it dry in upright position and protect it from sun, mechanical shocks, transportation requirements according to an order under the contract.
  • Page 38 Insert the right ID chip. Message: Insert the lot of Test Device is corresponding ID chip incompatible. Message: “Optical System Internal hardware failure Please Contact Wondfo Customer Fault”, “Transmission System Service Center. Fault”, and/or “Circuit System ” Fault - 37 -...
  • Page 39 Section Contact Information Guangzhou Wondfo Biotech Co., Ltd. ’s expressed and implied warranties are conditioned upon full observance of manufacturer’s published direction with respect to the use of Guangzhou Wondfo Biotech Co., Ltd. ’s products. Under no circumstance whatsoever shall Guangzhou Wondfo Biotech Co., Ltd.

This manual is also suitable for:

Fs-113

Table of Contents

Save PDF