  • Page 1 HPA Series Owner’s Manual Multi-Impedance High Power Amplifiers HPA2602 / HPA4202 Multi-Impedance High Power Amplifiers 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 1 – AtlasIED.com Specifications are subject to change without notice.
  • Page 2: Table Of Contents

    Connecting the HPA Amplifier to AC Mains - Best Practices ..............15 Optional Dante Input Card ........................16 Specifications ............................17 Warranty ..............................20 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 AtlasIED.com – 2 –...
  • Page 3: Important Safety Instructions

    Protective earthing terminal. The apparatus should be connected to a mains socket with a protective earthing connection. 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 3 – AtlasIED.com Specifications are subject to change without notice.
  • Page 4 Should any of the following irregularities occur during use, immediately switch off the power, disconnect the power cord from the AC outlet and contact AtlasIED. Do not to attempt to continue operation with the product as this may cause fire or electric shock: •...
  • Page 5: Introduction

    Multi-Impedance High Power Amplifiers Introduction Thank you for purchasing the AtlasIED HPA Series amplifier. The AtlasIED high power amplifier “HPA” Series is designed for use in both commercial 70V/100V distributed systems and professional applications that require amplifiers to handle multiple impedance loads. The HPA is compact and lightweight in comparison to other models delivering similar power levels.
  • Page 6: Front Panel Description

    Temp - This LED represents the temperature condition of the amplifier. The LED will illuminate yellow if any of the amplifier channels or power supply reaches 10% of their thermal protect threshold shut off. Note: Also refer to the Protect LED. 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 AtlasIED.com – 6 –...
  • Page 7 4. Failure of amp channel, if DC is present at the output the respective amp channel will go into protect. 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 7 – AtlasIED.com Specifications are subject to change without notice.
  • Page 8: Rear Panel Description

    The Standby LED will illuminate red as an indicator. HPA2602 - A 20A 16A/250V~ IEC-60320-C20 receptacle with a retainer clamp is provided for ease of power cord change out to meet global standards. A 3m 12-gauge power cord with a USA NEMA5-20 male plug is supplied in the carton. Insert the IEC power cord into the receptacle making sure it is securely placed with the retainer clamp.
  • Page 9: Bridge Mode Operation

    Stereo mode is when Input 1 is routed to Output 1 and Input 2 is routed to Output 2. 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 – 9 – AtlasIED.com Specifications are subject to change without notice.
  • Page 10: Remote Turn On

    Current Overdrive, if the amplifier channels are driving too low of a loudspeaker load. Failure of amp channel, if DC is present at the output the power supply will go into protect. Fault Reporting 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800.876.3333 • Fax: 800.765.3435 AtlasIED.com – 10 –...
  • Page 11 10. Accessory Card Slot The accessory card slot is for optional input cards such as the HPA-DAC2 (2 Channel Digital Audio Input Card). Contact AtlasIED for a full list of accessory cards. Note: Accessory card installation must be done by a qualified technician.
  • Page 12: Placement Of The Amp

    Note: The ground center pin of the Phoenix connector is common for both channels. Loudspeaker Outputs - Use 2 conductor unshielded wire of the appropriate gauge. If you are unsure about this, contact AtlasIED Tech Support at 1-800-876-3333. Make sure you know how many loudspeakers you need and what tap value you intend to use.
  • Page 13: Wiring The Hpa4202 Ac Mains

    As a convenience to the installer, a Locking 125V 30A NEMA L5-30P plug has been included. This is the most common 30A 125V plug used, and mates with the AtlasIED ECM-30 AC power module spike suppressor and sequenced outlet. This plug must be installed by a qualified technician.
  • Page 14 For North America 208V-240V Only AtlasIED recommends using a 208V - 240V power source. In most applications that require a high current demand, it is usually less expensive to pre wire a facility for 220V than 120V because of the reduced wire gauge requirements. In addition, there is far less potential for AC line voltage sag with 220V circuits than 120V circuits.
  • Page 15: Connecting The Hpa Amplifier To Ac Mains - Best Practices

    Never plug an amplifier into a circuit without knowing what other products are connected to the same circuit. 2. Never plug an HPA2602 or HPA4202 into a power strip. Always connect directly to a dedicated circuit wall receptacle. Power strips are not designed to deliver high amounts of continuous or peak current.
  • Page 16: Optional Dante Input Card

    The HPA amplifier series allows for an optional HPA-DAC2 2-Channel Dante™ receiver card to be installed into the HPA amplifier. Contact AtlasIED for a list of accessory cards. Note: Accessory card installation must be done by a qualified technician. Remove the HPA amplifier from the AC mains source.
  • Page 17: Specifications

    Auto Switch Mode 120V / 220V Amp Topology Class I Number of Fixed Inputs Accessory Inputs Optional Card Slot Output Power (Note 1) HPA2602 HPA4202 100V x 2 CH NA (Note 5) 2 x 2100W 70.7V X 2 CH 2 x 1300W 2 x 2100W 8Ω...
  • Page 18 Removable 30A 125V NEMA L5-30 Male Plug or User Select Power Cord (Ships With) IEC 12-Gauge 1.5M Cord w/ NEMA 5-20 Male Fixed, 10-Gauge 3M Cord, 1.5M Plug Power Consumption & Current Draw @ 120V AC Mains (HPA2602) Standby Mode 330mA 0.6W 2 BTU Idle Active 1.48A...
  • Page 19 4. Max Power is defined as 1KHz input signal applied to achieve the maximum power output before clip into a 4Ω or 70.7V load. 5. HPA2602 Max output Voltage is 85V. 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
  • Page 20: Warranty

    PARTICULAR PURPOSE. AtlasIED does not assume, or does it authorize any other person to assume or extend on its behalf, any other warranty, obligation, or liability. This warranty gives you specific legal rights and you may have other rights which vary from state to state.