Download Print this page

Output Format; Wiegand Output - Samsung SSA-R2003 User Manual

Rfid reader

Advertisement

output format

WIEGAND OUTPUT

Timing Diagram
100us
1ms
DATA-0
DATA-1
1
LOGIC
0
Data Type (26-bit)
Bit 1 : Even Parity (bit 2 ~ bit 13)
Bit 2 ~ 9 : Facility Code (000 ~ 255)
Bit 10 ~ 25 : ID Number (00000 ~ 65,535)
Bit 26 : Odd Parity (bit 14 ~ bit 25)
2
3
1
1
n-2
n-1
n *n : 34 or26
1
0
0
5V
0V
5V
0V
English _ 13