All names, trademarks, product names and other designations used in this manual may be legally pro- tected even if not indicated as such (e.g. as a trademark). KOSTAL Solar Electric GmbH assumes no li- ability for their free usage. The illustrations and texts have been compiled with great care. However, the possibility of errors cannot be ruled out.
Applications and functions....................Connecting an ENECTOR without KSEM ................ENECTOR with KSEM without PV system ................ENECTOR with KSEM and PV system................. ENECTOR with KSEM for house connection monitoring ............Installation ......................... General handling instructions....................Site selection ........................Permissible ambient conditions ...................
Page 4
Switching on wallbox......................Setting up wallbox in the KSEM ..................Possible configurations......................Setting up ENECTOR with convenience functions in the KSEM ........... ENECTOR with KOSTAL Smart Energy Meter for blackout protection (house connection monitoring) .......................... Operation ........................... Servicing ..........................Troubleshooting ........................
General information 1.1 Contact Thank you for choosing a device from KOSTAL Solar Electric GmbH! We hope you enjoy consistently high energy yields with your photovoltaic system. If you have any questions about your device, please contact your relevant service partner or our service hotline: ■...
Activities that may only be carried out by an electrician are marked separately. Pay particular attention to the information regarding safe usage. KOSTAL Solar Electric GmbH assumes no liability for damages arising from the non-ob- servance of this manual.
The device is only safe to use when used properly. Any other use or modifications to the device are considered improper and are therefore not permitted. The operator is responsible for the proper use and safe use. KOSTAL Solar Electric GmbH accepts no liability for the consequences of improper use.
Terminals in the device for connecting an optional push-button for switching conveni- ence functions (additional activation code required) ■ Terminals in the device for connecting an energy meter/energy manager (KOSTAL Smart Energy Meter) via Modbus RTU ■ Charging modes: Lock Mode (lock wallbox), Solar Pure Mode (solar charging) or Solar...
ENECTOR with convenience functions via KOSTAL Smart Energy Meter NOTE In order for the wallbox to be set up for the convenience functions in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code in the KSEM.
Page 23
Product description Lock Mode (lock wallbox) If a KOSTAL Smart Energy Meter (KSEM) is connected to the wallbox and the wallbox has been activated via an activation code in the KSEM, the wallbox can be locked via the KSEM. It can then only be unlocked by selecting another mode in the KSEM.
Page 26
Instead, it is reduced to the minimum charging power for approx. 5 min to avoid an interruption in charging after the vehicle has fre- quently switched charging on and off. ENECTOR with KOSTAL Smart Energy Meter for blackout protection (house connection monitoring) Blackout protection (house connection monitoring) The house connection is monitored when charging the electric vehicle.
The wallbox is booting. All LEDs off The wallbox is in energy-saving mode or switched off via the line circuit breaker. Flashing The wallbox has been locked via the KOSTAL quickly Smart Energy Meter. Lit up Wallbox active. After 10 minutes in this status, energy-saving mode is activated and the LED goes out.
Page 28
Vehicle is being charged at the set charging power of e.g. 11 kW (standard). Operating modes, Page 22. Switch the operating modes via KOSTAL Smart Energy Meter or push-button (optional). Lit up Solar Pure Mode (solar charging / surplus char- ging) is activated Operating modes, Page 22.
You can charge your electric vehicle between 1.4 kW-11 kW with the wallbox. The Solar Pure Mode (solar charging) or Solar Plus Mode (solar-optimised charging) func- tions are available when used in combination with a KOSTAL PV system and the KOSTAL Smart Energy Meter.
System overview 3.2 Connecting an ENECTOR without KSEM 1-phase or 3-phase connection Wallbox Wallbox 1x16 A / max. 3,7 kW 1x16 A / max. 11 kW Typ 2 Typ 2 3-pole 20 A Typ A Typ A 30 mA 30 mA...
(slave) is controlled by the KSEM (master) via Modbus RTU. NOTE In order for the wallbox to be set up in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code in the KSEM.
Page 33
Blackout protection (house connection monitoring) NOTE Here, the KOSTAL Smart Energy Meter monitors the amount drawn from the grid. If the grid demand exceeds the maximum current (e.g. 63 A per phase) configured in the wall- box, the charging power of the wallbox is reduced to remain below the maximum house connection capacity.
KSEM (master) via Modbus RTU. NOTE In order for the wallbox to be set up in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code in the KSEM.
Page 35
Blackout protection (house connection monitoring) NOTE Here, the KOSTAL Smart Energy Meter monitors the amount drawn from the grid. If the grid demand exceeds the maximum current (e.g. 63 A per phase) configured in the wall- box, the charging power of the wallbox is reduced to remain below the maximum house connection capacity.
System overview 3.5 ENECTOR with KSEM for house connection monitoring Wallbox 1x16 A / max. 3,7 kW Wallbox 3x16 A / max. 11 kW Typ 2 Typ 2 RS485 RS485 3-pole Modbus RTU Modbus RTU 20 A Typ A Typ A...
5.1 KOSTAL Smart Energy Meter connection For blackout protection (house connection monitoring), Solar Pure Mode, Solar Plus Mode or Lock Mode, a KOSTAL Smart Energy Meter with activated convenience func- tions is required; this is coupled to the ENECTOR via RS485.
Certain operating modes can only be switched via the KOSTAL Smart Energy Meter (KSEM) using an activation code. So that this does not always have to be done via the KOSTAL Smart Energy Meter, an op- tional push-button can be installed on the underside of the housing. You will find a descrip- tion of the function in Operating modes, Page 22.
Smart Energy Meter Bank 1 (S1) STATUS NETWORK SERIAL BUS REST KSEM Bank DIP switch ENECTOR with KOSTAL Smart Energy Meter and convenience functions 3x16 A 11 kW Bank 2 (S2) 63 A Smart Energy Meter Bank 1 (S1) STATUS NETWORK...
Page 60
Bank DIP switch NOTE In order for the wallbox to be set up with the convenience functions in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code for the wallbox in the KSEM.
Page 62
Unbalanced load limitation deactivated Unbalanced load limitation activated. Activate Modbus RTU If a Modbus RTU energy meter (KOSTAL Smart Energy Meter) is connected to the wallbox, the Modbus RTU protocol must be activated for this purpose. Configure the setting as desired.
Page 63
(blackout protection), Solar Pure Mode (PV surplus charging) and Solar Plus Mode (solar-optimised charging). If the KOSTAL Smart Energy Meter is connected to the wallbox as an energy meter, it can be used for grid monitoring (blackout protection). NOTE...
Page 64
If the KOSTAL Smart Energy Meter (KSEM) is used as an energy manager, the range of functions can be extended by entering an activation code in the KSEM. These functions in- clude, for example: ■...
Page 65
Activating convenience functions for KSEM If a PV system is present and if used in combination with the KOSTAL Smart Energy Meter and an activation code, the electric vehicle can be charged using the solar power generated.
Page 68
(e.g. 50 A downstream of grid demand meter). The lowest fuse protection (in this ex- ample 50 A) must be set here. With a KOSTAL Smart Energy Meter and activated convenience functions, this setting for overload protection is automatically transferred.
Page 72
Commissioning/configuration If the wallbox has been connected to a KOSTAL Smart Energy Meter as an energy meter and you have a PV system, the wallbox should be activated and set up via an activation code in the KOSTAL Smart Energy Meter Setting up wallbox in the KSEM, Page 73...
Setting up wallbox in the KSEM 7.1 Possible configurations The wallbox must be set up in the KOSTAL Smart Energy Meter (KSEM) so that the KSEM can control the wallbox or the wallbox can read data from the KSEM. There are two ways of doing this: ■...
With a PV system, functions such as Solar Pure Mode or Solar Plus Mode are possible. These can be selected as a function via the KSEM interface or using the KOSTAL Solar App. An activation code is required to set up the wallbox in the KSEM. NOTE In order for the wallbox to be set up in the KOSTAL Smart Energy Meter (KSEM), this function must first be activated via an activation code in the KSEM.
Page 77
All KOSTAL inverters and the KOSTAL Smart Energy Meter must be assigned to a PV sys- tem in the KOSTAL Solar Portal. If this was not been done when setting up your PV sys- tem, you must do it now.
(house connection monitoring) If the ENECTOR is connected to a KOSTAL Smart Energy Meter and this is only to be used for blackout protection (house connection monitoring), the RS485 interface used must be configured in the KOSTAL Smart Energy Meter.
Authorisation The wallbox can be used without authorisation. The electric vehicle can be charged at max- imum power. The wallbox can be locked via the KOSTAL Smart Energy Meter with convenience func- tions. Starting the charging process on the vehicle...
Page 80
- Solar Plus Mode (solar-optimised charging) NOTE The charging mode cannot be selected. If the wallbox has been set to Lock Mode via the KOSTAL Smart Energy Meter, no other mode can be selected via the optional push-button. ■ Wallbox can only be enabled via the KSEM.
If the wallbox has been set up in the KOSTAL Smart Energy Meter, the event messages are displayed in KSEM and in the KOSTAL Solar Portal. Explanations of the event messages can be found on the following pages.
Page 85
The DC residual current detection self-test Wallbox is defective and can only be re- fails. paired by the service team. Event messages in the KOSTAL Smart Energy Meter or KOSTAL Solar Portal Handling instruction for user prevent- aborting...
The wallbox software is updated to the latest version. To update the wallbox firmware, a CAN/USB cable, a PC and the configuration software are required. You can obtain these from our KOSTAL Service. NOTE The update may only be installed by an electrician.
Technical data 16. Technical data Subject to technical changes. Errors excepted. You can find current information at www.kostal-solar-electric.com. KOSTAL wallbox Unit ENECTOR AC 3.7/11 Mode 3 charging power (single-phase / 3.7 / 11 three-phase) Nominal voltage (U,n) AC ±10 % 230 / 400...