DUAL-FUEL GENERATOR WATT GASOLINE / 0 WATT PROPANE Please read and save these instructions. www.jdna.com...
Page 2
12000W Dual-Fuel Generator Topic Page Ytnarra WdetimiL Limitations and Exclusions Senilediu GytefaS Snoituacer PlareneG Battery Assembly Operation Spark Plug Service Inspection, Cleaning, Maintenance and Storage Installation Speci fications GnitsiLstra Plarene G altitude kit altitude kit...
Page 3
Dual-Fuel Generator JD North America warrants to the original purchaser who uses the product in a consumer application (personal, residential or household usage) that all products covered under this warranty are free from defects in material and workmanship for 2 years or 300 hours whichever comes first (1-year parts and labor and following 1 year parts only) from the date of purchase.
Page 4
Dual-Fuel Generator JD North America JD North America...
Page 5
Dual-Fuel Generator Limitations and exclusions This Limited Warranty shall not apply to: 1. Bent or broken crankshaft or resultant damage caused by vibration related to a bent or broken crankshaft. Also, damage caused by loose engine mounting bolts or improper or imbalanced accessories or blades mounted to the crankshaft. 2.
Owner’s Manual Safety Guidelines - Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions.
Dual-Fuel Generator General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE IN JURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING DANGER CARBON MONOXIDE Using a generator indoors WILL KILL YOU IN MINUTES.
Page 8
Owner’s Manual Gasoline or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state,or federal codes and regulations. Store oily rags in a covered metal container. If Propane is leaking, the valve must be closed immediately. Check for leaks and deal with them immediately. Never store fuel or other flammable materials near the generator.
Page 9
Dual-Fuel Generator General Precautions (cont’d) Work Area Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. Keep bystanders, children, and visitors away while operating a generator.
Page 10
Owner’s Manual General Precautions (cont’d) Electrical Safety (cont’d) All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation.
Page 11
Dual-Fuel Generator General Precautions (cont’d) Personal Safety (cont’d) Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use. Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is left attached to a rotating part of the generator may result in personal injury.
Page 12
Owner’s Manual General Precautions (cont’d) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If unreadable or missing, contact our service center toll free at 888-896-6881 immediately for a replacement. Generator service must be performed only by a qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury.
Page 13
Dual-Fuel Generator General Precautions (cont’d) Installation (cont’d) If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. The generator weighs 220 lbs (approx). Two or more people should assist when moving or lifting this product.
Page 14
Owner’s Manual General Precautions (cont’d) Mechanical (cont’d) • Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. • Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly.
Page 15
Dual-Fuel Generator General Precautions (cont’d) Extension Cord If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table: Nameplate Amps (@ full load) Cord Lengths 0 ft.- 50 ft.
Page 16
Owner’s Manual Battery To start generator electrically you will need have the battery installed correctly. This requires a 12v 18ah lawn tractor battery with the following dimensions: The dimensions are Wx7.5” Dx5” Hx7” (including terminals). A rated cranking amperage of 200. Terminals are regular, not reversed. Photos below demonstrate battery plate attachment.
Page 17
Dual-Fuel Generator Assembly Unpacking 1. Remove the generator and loose parts box from the carton. 2. Compare the accessory with the inventory list below. Loose Parts (Wheel kit and handle) Check all loose parts against the following list. Contact your dealer toll free at 888.896.6881 if any of the loose parts shown are not included with your generator Hardware Check: Your Hardware Kit should include:...
Page 18
Fuel tank Control Panel Choke lever Evaporative Tube Carburator Handle Battery Oil dipstick Change-over Switch Inlet connector Air filter Recoil Start...
Page 19
Dual-Fuel Generator Gasoline Starting. 1、Move the GAS-LPG switch clockwise to the vertical position. Put the circuit breaker to “OFF” position. 、 Disconnect any electric devices. ut the key switch on the “RUN” positi on. 3、 The engine switch enables and disables the ignition system. STOP: To stop the engine RUN: To run the engine START: To Start the engine...
Page 20
Owner’s Manual perate the Recoil Start: Pull the starter grip lightly until you feel resistance, then pull briskly. Return the starter grip gently. Pulling the starter grip operates the recoil start to Starter Grip crank the engine operate the Electric start: Push and hold the engine switch on the “START”...
Page 21
Dual-Fuel Generator Fully open the LPG cylinder fuel knob. 4. Put the circuit breaker to “OFF” position. Disconnect any electric devices. Move the choke lever to the “CLOSE” position. For restarting a warm engine, move the choke lever to the “OPEN” position.
Page 22
Owner’s Manual 7. Move the choke lever to the “OPEN” position. Push the circuit breakers to the “ON” position. Note: If you need to alternate fuel, you can change-over directly the GAS-LPG fuel switch while the generator is running at no-load. Stopping Engin e 1.
Page 23
Dual-Fuel Generator Operation (cont’d) Powering 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (120 V AC @ 66.7 AMPs) is adequate to supply all electrical loads that the unit will power.
Page 24
Owner’s Manual Operation (cont’d) Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (12V DC) is adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator.
12000W Dual-Fuel Generator Spark Plug Service In order to service the spark plug, you will need a spark plug w r ench (commercially available). Recommended spark plugs: NHSP LD F7TC or NGKBPRGES but we recommend our OEM spark plug. To ensure proper engine operation, the spark plug must be properly gapped and free of deposits.
Owner’s Manual Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “STOP” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING.
Dual-Fuel Generator Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1.
Page 28
Owner’s Manual Maintenance Guide Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. WARNING! Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the area is well ventilated. Before each use, inspect the generator.
Dual-Fuel Generator Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfuncion, service the air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas. WARNING! Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion.
Page 30
Owner’s Manual before use before use before use...
Page 31
Dual-Fuel Generator Transporting/Storage 1.Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. WARNING Gasoline is extremely flammable and is explosive under certain conditions. Perform this task in a well ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the area during this procedure.
Owner’s Manual Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPARATE GENERATOR.
Page 33
Dual-Fuel Generator Installation (cont’d) Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary.
Page 36
Dual-Fuel Generator Cylinder head system assy. Description APA Part No. JD Pa= = = r t No. HEAD COVER COMP. BOLT -A-01-JD JF240.1.1-4 -A-02-JD HEAD COVER WASHER COMP JF240.1.1-6 -A-03-JD WASHER COVER PACKING JF240.1.1-5 -A-04-JD HEAD COVER COMP JF240.1.3-1 -A-05-JD HEAD COVER PACKING JF240.1.1-3 -A-06-JD...
Page 49
Dual-Fuel Generator Muffler Assy. Part No. APA Part No. Descript io n -N-01-JD 20.4-M8*16 FLANGE BOLT (M8 X 16) -N-02-JD 20.4-M6*12 FLANGE BOLT (M6 X 12) -N-03-JD JD6500.17.10.1.5-1 MUFFLER STAY COMP. -N-04-JD JD6500.17.10.1.5-2 MUFFLER PROTECTOR SEAL -N-05-JD JD6500.17.10.1.5-3 MUFFLER SIDE PROTECTOR -N-06-JD JF340.7.2-3 MUFF.
Page 50
Dual-Fuel Generator Air Cleaner JD Part No. Description APA Part No. -O-01-JD AIR CLEANER COVER COMP JF240.6.2-1 -O-02-JD AIR CLEANER ELEMENT JF240.6.2-2 -O-03-JD FLANGE NUT (M5) 20.6-M5 JF240.6.2-4 -O-04-JD AIR CLEANER SEPARATOR -O-05-JD AIR CLEANER SEAL JF240.6.2-3 -O-06-JD JF240.6.2-5 AIR CLEANER CASE COMP JF240.6.1-6 -O-07-JD BREATHER GASKET...
Page 51
Dual-Fuel Generator Fuel Tank Assy. Descript io n JD Part No APA Part No. FUEL TANK CAP COMP. P-01-JD JD6500W-U.1.5-1.2 FUEL FILTER P-02-JD JD6500W-U.1.5-1.1 FUEL TANK COMP. P-03-JD JD10000W-U.1.5-1C FUEL TUBE JF168.8-1A P-04-JD FUEL SWITCH P-05-JD JF168.8-5 CLAMP, FUEL TUBE JF168.8-3 P-06-JD EVAPORATIVE TUBE...
Page 52
Dual-Fuel Generator Control Box Assy. 13 14 Description APA Part No. JD Part No. -Q-01-JD CONTROL PANEL COMP. HC001-MB -Q-02-JD ENGINE SWITCH ASSY. 21.3.1-13 21.3.4-15 -Q-03-JD DC 12V OUTPUT 21.3.16-2 -Q-04-JD HOURS METER 21.3.4-5 -Q-05-JD 120V RECEPTACLE(Ru-22) 21.3.7-7 -Q-06-JD CIRCUIT BREAKER (SINGLE, 20A) 21.3.4-6 -Q-07-JD 120V RECEPTACLE(L5-30)
Page 53
Dual-Fuel Generator Frame Comp Assy. Description APA Part No. JD Part No. GENERATOR FRAME -R-01-JD JD6500.17.10.1-J109 CONTROL PANEL CASE -R-02- JD 21.3.25-11...
Page 54
Dual-Fuel Generator Generator 7 11 APA Part N JD Part No Description Qty. -S-01-JD STATOR COVER 7KW.25.3A 7.0KW.25.04B -S-02-JD STATORASSY 5KW.25.2-8A -S-03-JD COOLING FAN 5KW.25.4A -S-04-JD BRUSH ASSY 20.4-M5*16*0.75 -S-05-JD TAPPING SCREW JF240.22-1 -S-06-JD RR HOUSING 20.9-M5 -S-07-JD SPRING WASHER (5mm) 20.3-M6*187 -S-08-JD FLANGE BOLT (M6X 179)
Page 55
Dual-Fuel Generator Generator APA Part No. JD Part No. Description -S-18-JD 20.4-M5*16*0.75 HEX.BOLT (M5 X 20) 2KW.25.5-1 -S-19-JD VOLT CHANGE TERMINAL BR-AC-W 20.9-M5 -S-20-JD PLAIN WASHER (5mm)
Page 56
Dual-Fuel Generator Wheel & Hand Assy. 10 11 Description APA Part N JD Part No Qty. -T -01-JD PIN SPLIT JD6500.17.10.1-1 JD6500.17.10.1-2 -T-02-JD WSHER PLAIN 10 inch wheel -T-03-JD WHEEL JD6500.17.10.1-J109.1-1 -T-04-JD BAFFLE -T-05-JD JD6500.17.10.1-J109.1 SHAFT 20.4-M6*45 -T-06-JD FLANGE BOLT (M6X 45) 20.6-M6 -T-07-JD FLANGE NUT (M6)