1 Safety Precautions 1.1. General Guidelines 1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or damaged by the short circuit. 2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly installed.
2 Warning 2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and semiconductor [chip] components.
2.2. About lead free solder (PbF) Note: Lead is listed as (Pb) in the periodic table of elements. In the information below, Pb will refer to Lead solder, and PbF will refer to Lead Free Solder. The Lead Free Solder used in our manufacturing process and discussed below is (Sn+Ag+Cu). That is Tin (Sn), Silver (Ag) and Copper (Cu) although other types are available.
5 Technical Descriptions 5.1. Specification of KEY for HDCP2.0, Widevine, Mac and DIMORA-ID 5.1.1. General information: 1. eMMC Memory (IC8903) for spare parts has the seed of KEY for each. 2. The final KEY data will be generated by Main IC (IC8000) when SELF CHECK was done and are stored in both Main IC (IC8000) and eMMC (IC8903).
6 Service Mode 6.1. How to enter into Service Mode 6.1.1. Purpose/ After exchange parts, check and adjust the contents of adjustment mode. While pressing [VOLUME ( - )] button of the main unit, press [INFO] button of the remote control three times within 2 seconds. 6.1.2.
6.2. SRV-TOOL 6.2.1. How to access 1. Select [SRV-TOOL] in Service Mode. 2. Press [OK] button on the remote control. 6.2.2. Display of SOS History SOS History (Number of LED blinking) indication. From left side; Last SOS, before Last, three occurrence before, 2nd occurrence after shipment, 1st occurrence after shipment. This indication except 2nd and 1st occurrence after shipment will be cleared by [Self-check indication and forced to factory shipment setting].
6.3. Hotel mode 1. Purpose Restrict a function for hotels. Item Function 2. Access command to the Hotel mode setup menu Mode Select hotel mode On/Off In order to display the Hotel mode setup menu: Input Select input signal modes. While pressing [VOLUME (-)] button of the main unit, Set the input, when each time power is switched on.
6.4. Data Copy by USB Memory Note: SD card can not be used for Data Copy. 6.4.1. Purpose (a) Board replacement (Copy the data when exchanging A-board): When exchanging A-board, the data in original A-board can be copied to USB Memory and then copy to new A-board. (b) Hotel (Copy the data when installing a number of units in hotel or any facility): When installing a number of units in hotel or any facility, the data in master TV can be copied to USB Memory and then copy to other TVs.
Page 13
6.4.3. Data copy from TV set to USB Memory 1. Turn on the TV set. 2. Insert USB Memory with a startup file (pwd file) to USB terminal. On-screen Display will be appeared according to the startup file automatically. 3. Input a following password for (a) or (b) by using remote control. (a) For Board replacement : 2770 (b) For Hotel : 4850 Data will be copied from TV set to USB Memory.
Page 14
6.4.4. Data copy from USB Memory to TV set 1. Turn on the TV set. 2. Insert USB Memory with Data to USB terminal. On-screen Display will be appeared according to the Data folder automatically. 3. Input a following password for (a) or (b) by using remote control. (a) For Board replacement : 2771 (b) For Hotel : 4851 Data will be copied from USB Memory to TV set.
7 Troubleshooting Guide Use the self-check function to test the unit. 1. Checking the IIC bus lines 2. Power LED Blinking timing 7.1. Check of the IIC bus lines 7.1.1. How to access 7.1.1.1. Self-check indication only: Produce TV reception screen, and while pressing [VOLUME ( - )] button on the main unit, press [OK] button on the remote control for more than 3 seconds.
7.2. Power LED Blinking timing chart 1. Subject Information of LED Flashing timing chart. 2. Contents When an abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the defective block can be identified by the number of blinks of the Power LED on the front panel of the unit. Blinking Times Contents Check point...
8 Disassembly and Assembly Instructions 8.1. Disassembly Flow Chart for the Unit This is a disassembly chart. When assembling, perform this chart conversely. 8.2. Disassembly Procedure for the Unit 8.2.1. Pedestal 8.2.2. Back cover 1. Lay down the unit so that the rear cover faces upward. 1.
Page 18
8.2.3. P-Panel 8.2.5. Heat sink bottom 1. Disconnect the connectors P2 and P5. 1. Remove the 7 screws (THEC1509). 2. Remove the 7 screws (THEJ036J). 2. Remove the Heat sink bottom. 3. Remove the P-Panel. 8.2.6. Circuit Units 1. Remove the screw (THEJ036J). 2.
Page 19
8.2.8. WiFi Metal 8.2.10. K-Panel 1. Remove the screw (THEJ036J). 1. Remove the K panel preparation. 2. Remove the WiFi Metal. 2. Disconnect the connector K10. 3. Remove the Led panel. 4. Remove the K-Panel. 8.2.9. GK-Panel 1. Disconnect the connector GK4. 2.
Page 20
8.2.15. LCD MTG Bottom 3. Remove the screw (THEJ036J). 4. Remove the bluetooth bracket. 1. Remove the LCD MTG Bottom. 8.2.12. Bottom Metal 8.2.16. SP Bracket 1. Remove the 4 screws (THEJ036J). 1. Remove the 4 screws (THEJ036J). 2. Remove the Bottom Metal. 2.
11 Wiring Connection Diagram 11.1. Caution statement. Caution: Please confirm that all flexible cables are assembled correctly. Also make sure that they are locked in the connectors. Verify by giving the flexible cables a very slight pull. 11.2. Wiring (1)
Need help?
Do you have a question about the TC-42AS650L and is the answer not in the manual?
Questions and answers