Download Print this page

Sealey D200T Quick Start Manual page 2

Portable diesel tank 200ltr 12v

Advertisement

4. OPERATION
4.1.
TRANSPORT
4.1.1.
Move the empty tank assembly with two persons using the hand holds moulded into the base of the unit (fig.1A.8).
4.1.2.
Move by forklift truck using the fork locations shown in (fig.1A.7). Ensure that the filler (fig.1A.1) is closed before moving.
4.1.3.
Secure the tank to the carrying vehicle by ratchet straps. Locations for the straps are moulded into the tank (fig.1A.5).
4.2.
FILLING
4.2.1.
DO NOT run the pump without fuel in the tank. To do so will damage the pump's internal components and will invalidate your warranty.
4.2.2.
The tank is filled by unscrewing the filler (fig.1.1) in an anticlockwise direction. Refit the filler cap immediately after filling.
WARNING take care not to overfill the tank.
4.3.
FUEL DISPENSING
4.3.1.
Before connecting to a battery, make sure that the pump switch (fig.5.2) is in the 'off' (O) position. Connect the battery clips to the
12V battery, observing correct polarity (red clamp to +ve terminal, black clamp to -ve terminal)
4.3.2.
Switch the pump switch to the 'on' (I) position.
4.3.3.
Unwind sufficient hose and place the nozzle (fig.4) in the receiving tank and pull the trigger (fig.4). Delivery will commence and
continue until the trigger is released.
4.3.4.
The trigger can be locked in one of three positions by engaging the latch (fig.4) to hold the trigger open. DO NOT leave the nozzle
unattended with the trigger latched open.
4.3.5.
Slight pressure on the trigger will release the latch.
4.3.6.
When the level in the receiving tank reaches the nozzle, delivery will stop automatically.
4.3.7.
When delivery is complete, switch off the pump. Ensure the hose is wound into its housing on the tank and that the nozzle is
secured in its storage place.
4.3.8.
DO NOT operate the pump continuously for more than 30 minutes. The duty cycle of the unit is 30 minutes, after which the motor must
be left to cool down for a further 30 minutes.
4.3.9.
DO NOT run the unit for more than 2-3 minutes with the delivery nozzle closed.
5. MAINTENANCE
5.1.
The pump contains no user-servicable parts.
Repairs should only be undertaken by competent
persons.
5.2.
Check the integrity of all the hose connections
periodically. If any leakage is evident, strip the
joint and wind PTFE tape around the male thread.
5.3.
Check all electrical connections and cables for wear
and damage. Rectify any faults found.
5.4.
Keep clean, especially the dispenser nozzle.
5.5.
Clean with a damp, soapy cloth.
5.6.
DO NOT use abrasive or solvent cleaners.
fig.4
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
fig.3
fig.5
5
2
01284 703534
Original Language Version
8
8
sales@sealey.co.uk
1
5
7
7
www.sealey.co.uk
D200T | Issue 1 26/11/18

Advertisement