FeelTech Contents Guaranty and Declaration ................... I Product Introduction ..................1 Quick Start ......................5 General Inspection..................5 Front Panel Overview ..................6 Back Panel Overview ..................9 Power On and Inspection ................11 User Interface ....................12 Appearance and Dimensions ................ 14 Front Panel Operations ..................
FeelTech Product Introduction This manual applies to each model of FY6600 series Function/Arbitrary Waveform Signal Generator. The last three characters of the model indicate the up limit output of Sine Wave (MHz). For example, the “60M” of the Model Number “FY6600-60M”...
Page 6
FeelTech Main Features: Adopt DDS technology to generate accurate, stable signal with low distortion. Adopt ABS plastic shell with table type design. Use 100-240V (AC) wide range voltage power supply. 2.4 inch TFT Color LCD with 320 × 240 resolution can display all the parameters of both channels and current functions of all buttons .
Page 7
FeelTech It has 64 positions for saving user-defined waveform. Waveform Length of each one is 8192 * 14 bits. High frequency precision up to orders of magnitude. Full range of 1μHz (0.000001Hz) frequency resolution. Minimum amplitude resolution can be up to 1 mV(0.001V).
Page 8
FeelTech program and the communication protocol is open for secondary development. Output short-circuit protection: All channels can work more than 60 seconds when the load is short-circuited. Can choose our FYV2000 series or FPA1000 series power amplifier to output 20W or higher signals in DC-10MHz width without any distortion.
FeelTech Quick Start General Inspection Please follow the items below when you receive a new FY6600 series Function/Arbitrary Waveform Generator. 1. Inspect the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests.
FeelTech Front Panel Overview The front panel is divided into several function areas for easy operation. Front Panel Item Function Description Press this buttons to switch waveforms among Sine, Square, Triangle and so on. Press this button to switch between frequency meter and counter to measure frequency, period, duty cycle and pulse width of external signal output.
Page 11
FeelTech — Switch Master-Slave status — Set default status of dual channels at start-up. Trigger and modulation function button Set definite amount of pulse string to output. Set modulation mode: ASK, FSK, PSK 2.4 inch TFT(320×240)color LCD. Operation instruction please check chapter “User Interface”.
Page 12
FeelTech CH2 channel CH2 connector, output impedance is 50Ω. output When CH2 channel activates (indicator illuminates), CH2 outputs connector signal with parameters set. AC coupling BNC connector, input impedance 100Ω. For inputting signal of meter or measuring counter. terminal FY6600 Series User’s Manual...
FeelTech Back Panel Overview The back panel of FY6600 is as picture 1-2 below. 4 BNC terminals on the left are DC coupling measuring terminals Trig/FSK/ASK/PSK IN, external sweep input VCO IN, Synchronization output connector SYNC OUT, and Synchronization input connector SYNC IN. Then follows TTL output terminal, USB terminal, power switch and power input socket.
Page 14
FeelTech Warning To avoid instrument damage, voltage of signal input from EXT.IN CANNOT exceed ±20Vac+dc.Voltage of signal input from Trig/FSK/ASK/PSK IN CANNOT exceed DC5V. Note To ensure the normal work, please use 100-240V AC power supply. FY6600 Series User’s Manual...
FeelTech Power On and Inspection Connect to Power Please connect the generator to AC power supply using the Power cable supplied in the accessories. The power supply use 100-240V AC power. The power of this instrument is less than 5W.
FeelTech User Interface The user interface of FY6600 provides four types of display modes: Dual Channels Parameters (default), Single Channel Extension, Auxiliary Functions and System Interface. Dual Channels Parameters (default) The upper half of LCD displays the channel selected currently and the parameters can be set.
Page 17
FeelTech Frequency Display frequency value of current channel. Press FREQ button to highlight it and use ADJ Knob and Arrows to change the value. Amplitude Display amplitude value of current channel. Press AMPL button to highlight it and use ADJ Knob and Arrows to change the value.
FeelTech Front Panel Operations Waveform Output FY6600 series can output waveforms (Sine, Square, Triangle/Ramp, Pulse and Noise etc.) from one of the channels separately or from the two channels at the same time. At start-up, the dual channels are configured to output a sine waveform with 10kHz frequency and 5Vpp amplitude by default.
Offset √ √ √ √ √ Phase √ Duty Cycle Note: Arbitrary waveforms can be edited and downloaded from PC software provided by FeelTech. The relevant software and driver can be downloaded from our website: www.feeltech.net FY6600 Series User’s Manual...
FeelTech Set Frequency Frequency is one of the most important parameters of waveforms. For different instrument models and waveforms, the setting ranges of frequency are different. detailed information, please refer “Frequency” “Specifications”. The default frequency is 10kHz. Press FREQ button to highlight value of Frequency. Then use Arrow buttons and ADJ Knob to set the value.
FeelTech Set Amplitude The amplitude setting range is limited by the “Attenuation” and “Frequency” settings. Please refer to “Output Characteristics” in “Specifications”. The default value is 5Vpp. Press AMPL button to highlight amplitude value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value.
FeelTech Set Offset Press OFFS button to highlight offset value. Then use Arrows button and ADJ Knob to set the value. Press Arrows button to move the cursor and rotate ADJ Knob to set the value. The offset accuracy is 1mV. i.e. 0.001V.
FeelTech Set Duty Cycle (Square) Duty cycle is defined as the percentage that the high level takes up in the whole period (as shown in the figure below). This parameter is only available when square is selected. The setting range of duty cycle is limited by the “FREQ” setting. Please refer to “Waveform Characteristics”...
FeelTech Set Phase The setting range of phase is from 0° to 359.9° . The phase resolution is 0.1° . The default phase value is 0° The start phase displayed on the screen is the default value or the phase previously set.
FeelTech Enable Output After configuring the parameters of the waveform selected, waveform output could be enabled. At start-up output of CH1 and CH2 are both turned on as default. At this time indicator lights of dual channels illuminate. The default status can be modified. Press【SYS】button and then press【MORE】...
FeelTech Example: Output Sine Waveform This section mainly introduces how to output a sine waveform (Frequency: 20kHz, Amplitude:2.5Vpp, DC Offset: 1.6VDC, Start Phase: 90.9° ) from the [CH1] channel. 1. Select output channel Press CH1 to select CH1. Now all characters and border of the channel is displayed in yellow.
FeelTech Burst FY6600 can output waveform with specified number of cycles (called Burst) from the CH1 channel. FY6600 supports control of burst output by CH2(internal), manual or external trigger source; The signal generator can generate burst using Sine wave, Square wave, Ramp wave, Pulse, Noise wave or arbitrary waveform (except DC).
Page 30
FeelTech Numerical Modulation Press BURST button to enter numerical and trigger function, then press the relevant button to enter relevant modulation function. Modulation mode can be external modulation and manual modulation. Modulation signal can be input from Trig/FSK/ASK/PSK IN on the back.
FeelTech Frequency Meter/Counter FY6600 provides a counter which can measure various parameters of external input signal such as frequency, period, duty cycle, positive pulse width and negative pulse width. Dual channels output can work together with counter. Enable the Counter Press MEAS button of the front panel to enable the counter and measurement Manu.
FeelTech Set the Counter Gate Time Press GATE button to select gate time. The default is “1S”. It’s better to use “10S” or “100S” as gate time for low frequency signal. Gate Time Frequency Resolution 0.1Hz 100S 0.01Hz Coupling Set the coupling mode of the input signal to “AC” or “DC” and the default is “AC”.
FeelTech Sweep Press SWEEP button of front panel to enable sweep function. FY6600 can output sweep from CH1. In sweep mode, the generator outputs signal variably from the start frequency to stop frequency within the specified sweep time. It can generate sweep output for Sine, Square, Triangle/Ramp and arbitrary waveform.
FeelTech Sweep Start Position When Sweep function is enabled. Sweep start position need to be set according to sweep objects. Frequency Sweep: Press STAR button to highlight start frequency parameter. Press the Arrow buttons and rotate the ADJ Knob to set the specified value.
FeelTech Sweep End Position When Sweep function is enabled. Sweep end position need to be set according to sweep objects. Frequency Sweep: Press END button to highlight end frequency parameter. Press the Arrow buttons and rotate the ADJ Knob to set the specified value.
FeelTech Sweep Time When Sweep function is enabled, press SOUR button to select it and press it again to change between TIME and external sweep (VCO Sweep). Press the Arrow buttons and rotate the ADJ Knob to set the specified value of weep time.
FeelTech Sweep Type FY6600 provides Linear, Logarithm sweep types. The default is Linear sweep. The sweep type can be switched by pressing “MODE” button. Linear Sweep In linear sweep type, the signal parameter varies linearly. For example, in the frequency sweep the output frequency of the instrument varies linearly in the way of “Changing several Hertz per second”.
FeelTech Enable Sweep Function Press SWEEP button of front panel to enable sweep function. Then press ADJ Knob to start sweep process. Press ADJ Knob again to stop sweep. Start value and End value Start value and stop value are the upper and lower limits of sweep for specified parameter.
FeelTech System Configuration and Auxiliary Functions Press SYS button of front panel to enter System interface. The interface displays the instrument parameter storage [SAVE] , parameter loading [LOAD] , configuration [CONF] and other functional [MORE] information. SAVE: To save current parameters of waveform to save positions (20 sets).
FeelTech Save and Load Press SAVE button in System interface to save parameters of current waveform to specified position. Press LOAD button to load parameters of waveforms previously set to current system status. Select S xx on the right to save current parameters to corresponding position.
FeelTech Configuration Press SYS button to enter system interface. Then press CONF button to enter system configuration interface. Press corresponding buttons to select system work mode. Press 中文 button to select Chinese as system language. Press Eng button to select English as system language.
FeelTech Uplink FY6600 supports multi-machine uplink, which can provide users more channels for output. In uplink network, only one master machine can exist. Others must be set as slave machine. The setting method is as follows: Select on FY6600 as master machine. Press SYS -> CONF ->M/S, to set the UPLINK MODE to be “Master”.
FeelTech Synchronization Press the [SYNC] button to enter the synchronization function setting interface. Press corresponding buttons on the right to highlight or cancel selecting status. When the synchronization of corresponding parameters are activated, the corresponding parameters of CH2 will vary according to variation of CH1 automatically.
4) Check whether the indicators of CH1 or CH2 is turned on. If not press corresponding button to turn it on. 5) If the problem is still, please contact FeelTech. FY6600 Series User’s Manual...
FeelTech Technical Specification Unless specified, all specifications can be guaranteed if the following two conditions are met. The generator has passed self-inspection. The generator has been working continuously for at least 30 minutes under the specified temperature (18℃~28℃).
Page 47
FeelTech High Electric Level 1V~10V ≤20ns Rise/Fall Time External Measurement Range 0.01Hz~100MHz Frequency Meter Gate Time 3 grades(1S, 10S, 100S) Sensitivity adjustable Range 0-4294967295 Counter Coupling DC , AC Working Mode Manual Voltage Input 2Vpp~20Vpp Range Pulse Width Resolution 5 nS.
Page 48
FeelTech Pulse Quantity 1-1048575 Burst Mode Manual, CH2, External General Specifications Display Mode 2.4 inch TFT Color Lcd. Amount Save & Load Position 01 to20 (01 for start default value) Type USB to Serial interface. Communicati Interface 9600bps (Industrial standard)
FeelTech Appendix Appendix A:Safety Notes 1. Before using this instrument, please check if the power supply is normal, to ensure the normal use and personal safety. 2. This instrument must be used in the technical index range. 3. Please do not change the instrument circuit arbitrarily, so as to avoid damaging equipment or endangering the safety.
Page 50
FeelTech Appendix D:Warranty FeelTech warrants that its products mainframe and accessories will be free from defects in materials and workmanship within the warranty period. If a product is proven to be defective within the respective period, FeelTech guarantees the free replacement or repair of products which are approved defective.