Toshiba TEC EO1-32003 Owner's Manual page 91

Electronic computing scale
Table of Contents

Advertisement

15. ERROR MESSAGE TABLE
CMT Operation Mode
Message
MISMATCH SCALE SPEC
BAD TAPE OR CMT
TIME OUT ERROR
LON System Mode
Message
COMMUNICATION
ERROR
SEQUENCE ERROR The power was not turned OFF and
SEQUENCE NO.
ERROR
MASTER BUSY
BACKUP MASTER
NOT RESET
TEXT ERROR ##
Cause
Mismatch of the model type.
Mismatch of the base unit.
Mismatch of the VERSION.
Mismatch of the
TRANSMITTING DATA.
Mismatch of the scale capacity.
Parity error
Framing error
Overrun error
Data error
Two or More Hardware error
Time out error
Cause
1. The power of the master or
backup master scale is not turned
ON.
They are not connected with each
other or in off-line state.
2. LON cable is broken.
ON again after setting ID #.
Text data number is incorrect.
Registration job is performed on a
satellite scale while reset job is
performed on the master scale.
The backup master does not have
the same PLU with the master scale.
1. Error text is found.
02: Sequence No. error
05: LRC error
08: Text error
09: Command error
2. The master scale differs from
other scale in ROM version.
M: Master scale
15- 3
15. ERROR MESSAGE TABLE
Solution
CLEAR
Press the
CLEAR
Press the
CLEAR
Press the
Solution
1. Turn the power of the master or
backup master scale ON.
Connect them with each other
or turn the scale in-line.
2. Call your authorized service
representative.
Turn the power switch OFF and
ON again.
Call your authorized service
representative.
1. Quit reset job on the master
scale.
2. Quit registration job on the
satellite scale.
Down load PLU from the master
to the backup master scale.
Then run the reset operation
again.
Call your authorized service
representative.
BM: Backup master scale S: Satellite scale
key
key
key.
M BM/S

Advertisement

Table of Contents
loading

Table of Contents