Command
RemoteSync
RemoteSync 0 | 1
Examples
>RemoteSync
0
>RemoteSync 1
>FrameIP 192.168.2.61
>
The first command in the above examples queries the current value of the remote sync option, which returns 0
(disabled, the default). The second command enables remote syncing and the final command sets the IP address
of the router to sync (secondary router).
3.11.38 S Command
Routers and MSC-GCP2U32 only
Query the current matrix routing state. Source values for all levels of every destination are shown. This
command without an argument is equivalent to the
is supplied, then the matrix state is displayed with labels. The state of each destination is displayed, one per
line, in the format:
"DestNLvl1":"SrcLvl1","DestNLvl2":"SrcLvl2",...
Example
>S1
"Dest1":"Src4","Dest1":"Src4"
"Dest2":"Src3","Dest2":"Src3"
"Dest3":"Src2","Dest3":"Src2"
"Dest4":"Src1","Dest4":"Src4"
The example above is output from a two level (Video and Audio for example) 4x4 matrix with sources routed in
reverse order, except destination 4, which has a 2nd level break away which is routed from source 4.
3.11.39 SerBaud Command
NOTE: Superseded by the ctl.serial.baud and ctl.serial2.baud
Query or assign the RS-232 serial port baud rate. The default value is 115200. This value is stored and recalled
on power up.
Command
SerBaud
SerBaud BAUD
Examples
Page 45 of 60
MSC-DE3248 Product Manual
Description
Query current value of remote router syncing.
Enable or disable remote router syncing (1 or 0 respectively).
X Command
Description
Query the current serial port baud rate.
Set the serial port baud rate.
© 2013-2019 Matrix Switch Corporation
with no arguments. If an argument value of '1'
System Paramete rs
.
www.matrixswitch corp.com